Войти:
Оценок - 3, средний балл: 3 ( )

Инструкция по эксплуатации Haier, модель AB36NACBEA

Производитель: Haier
Размер: 745.11 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Optimal temperature Effectively use timer. Using TIMER mode, you can make the room temperature reach a suitable temperature when you wake up or back home. 17 Installation Procedure Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil Standard accessories The following parts mentioned in this manual are the installation accessories we prepared. Following in the list are the accessories supplied with the unit,which can be used as required (For series 24 28 36 42 52 ) No. Accessory parts Qty. 1 Remote controller 1 2 Battery 2 3 Wire clamp 4 4 Heat insulation sheathing 1+1 5 Accesories 1 6 Screw cap 1+1 7 Remote controller bracket 1 (For series 14 18) Symbol Parts Name A Adhesive tape B Pipe clamp C Connecting hose D Drainage hose E Non-hydroscopic heat insulating material F Gypsum powder No. Accessory parts Qty. 1 Remote controller 1 2 Battery 2 3 Wire clamp 4 4 Heat preservation sleeve 1+1 5 Screw 2+4 6 Screw cap 1+1 7 Remote controller bracket 1 18 Installation Procedure CAUTIONS: To ensure proper installation, read "Cautions" carefully before working. After installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed. WARNING! Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will cause water leakage, electric shock or fire. Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire accident. Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or unit falling down may happen. Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries. When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may cause unit to fall down. All electric work shall be done by experienced people as per eocal code, regulations and this Manual. Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric shock or fire accident. All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident. Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to avoid overheat, electric shock or even fire accident. In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room. Poisonous gas will occur when meet with fire. Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc. Cut power supply before touching terminal bolck. CAUTION! Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Earthing Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur. Unproper installation of water drainage will cause water leakage and wer your furniture. To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and ou tdoor unit, connecting wire and power line. (If the radio wave is relatively strong, 1 m is not enough to reduce noise). Don't install unit in following places: (a) Oil mist or oil gas exists, such as kitchen, or, plastic parts may got aged, or water leakage. (b) Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion, causing leakage. (c) Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit (d) Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter might cause fire accident. Refer to paper pattern when installing unit. Cautions for the installation personnel Don't fail to show customers how to operate unit. 19 Installation Procedure 1 BEFORE INSTALLATION Determine the way to carry unit to installation place. Don't remove packing until unit reaches installation place. If unpacking is unkavoidable, protect unit properly. 2 SELECTION OF INSTALLATION PLACE (1) Installation place shall meet the following and agreed by customers: Place where proper air flow can be ensured. No block to air flow. Water drainage is smpoth. Place strong enough to sup...

Эта инструкция также подходит к моделям:
Кондиционеры - AB142ACBEA (745.11 kb)
Кондиционеры - AB242ACBEA (745.11 kb)
Кондиционеры - AB28NACBEA (745.11 kb)
Кондиционеры - AB42NACBEA (745.11 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории