Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Panasonic, модель CUA18CKP6G

Производитель: Panasonic
Размер: 3.56 mb
Название файла: CSA18CKPG.PDF
Язык инструкции:enessl
Перейти к скачиванию



Фрагмент инструкции


• Operation with the standard temperature. • Operation with 4° F lower than the standard temperature. Standard Temperature • At the beginning of the automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the indoor temperature. • The operation mode changes every hour, when necessary. Cooling Soft Dry Heating 77° F 72° F 70° F COOL DRY HEAT 75° F ~ 78° F 2° F ~ 4° F Lower than the room temperature 68° F ~ 75° F Operation Standard temperature Indoor temperature 73° F 68° F 5 1 34 2 5 PREPARATION BEFORE Indoor Unit 1 Open the front panel 2 Remove the air filters 3 Fit the air purifying filters in place 4 Insert the air filters 5 Close the front panel Remote Control – To set the current time 1 Press 1. 2 Then press 2to increase or decrease the time. 3 Press 1 again. Set time on display will light up. RESET CLOCK FAN SPEED AIR SWING OFF CANCEL ON SET 1 2 3 TIMER 1 2 HOW TO OPERATE To start the operation • Press 1. • POWER indicator (green) on the indoor unit will light up. • To stop, press once more. Setting Mode • Press 2 to select:AUTO – Automatic Operation HEAT – Heating Operation COOL – Cooling Operation DRY – Soft Dry Operation TEMP AUTUTO AUTUTOFANAN AUTUTO AUTUTO AIR SWING1 2 3 OFF/ON POWERFUL ECONOMY SLEEPON FAN SPEED MODE 235164 Setting Temperature • Press 3 to increase or • The temperature F ~ 86° F. • Recommended temperature: • During AUTO Operation, press 3 to select:• Operation with 4° F higher than the standard temperature. • Operation with the standard temperature. • Operation with 4° F lower than the standard temperature. Standard Temperature • At the beginning of the automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the indoor temperature. • The operation mode changes every hour, when necessary. Cooling Soft Dry Heating 77° F 72° F 70° F COOL DRY HEAT 75° F ~ 78° F 2° F ~ 4° F Lower than the room temperature 68° F ~ 75° F Operation Standard temperature Indoor temperature 73° F 68° F 5 1 34 2 ENGLISH Setting the • Press 4 to select:FAN – Low Fan Speed FAN – Medium Fan Speed FAN – High Fan Speed AUTO FAN – Automatic Fan Speed The speed of the indoor fan is automatically according to the operation. The indoor fan stops occasionally during cooling operation. Setting the Vertical Airflow Direction • Press 5 to select: Setting the • Press 6 to select: Notes • If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote control. • If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes. Operation COOL – Cooling Operation • To set the room temperature cooling comfort level. AUTO – Automatic Operation • Sense indoor temperature to select mode. • Temperature is not displayed on the during AUTO operation. DRY – Soft Dry Operation • A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature. • During Soft Dry operation, the indoor fan operates at Low fan speed. HEAT – Heating Operation • Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced. • Defrosting Operation Depending on the outdoor temperature, the operation occasionally stops to melt the frost on the outdoor unit. AUTO • For COOL/DRY operation. Swing up/down automatically. • For HEAT operation When the discharge air temperature is low such as at the start of the heating operation, the air blows at horizontal level. As the temperature rises, the hot air blows in a downwards direction. AUTO AUTO AUTO Horizontal Airflow Direction Indoor Unit Remote Control • For COOL/DRY operation. Swing left/right automatically. • For HEAT operation When the discharge air temperature is low, there is no air swing. When the temperature rises, the horizontal airflow louvers swing left/right automatically. AUTO AUTO Use this air conditioner under the following conditions: DBT: Dry Bulb Temp WBT: Wet Bulb Temp Maximum Temperature-Cooling (Maximum Temperature-Heating) Minimum Temperature-Cooling (Minimum Temperature-Heating) DBT 89.6 (86) 60.8 (60.8) WBT 73.4 (-) 51.8 (-) DBT 109.4 (75.2) 60.8 (23) WBT 78.8 (64.4) 51.8 (21.2) Indoor Outdoor (Unit in ° F) 6 7 SETTING THE TIMER Ensure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing. ON-TIMER Operation To start the air conditioner operation automatically. • Press 1 to set the operation. • Press 2 to increase or decrease the time. • Then press 3. • To cancel this operation, press 4. OFF-TIMER Operation To stop the air conditioner operation automatically. • Press 5 to set the operation. • Press 2 to increase or decrease the time. • Then press 3. • To cancel this operation, press 4. Timer Mode Operation Details • Wh...

Эта инструкция также подходит к моделям:
Кондиционеры - CS-A18CKPG (3.56 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории