models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. - = Not applicable. 6 Unitary Products Group 036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RATED CFM NET MBH SEER W/O TXV SEER + TXV1 EER TOTAL SENS. 14,17 G1FA024S14,17 600 19.2 13.0 12.00* 12.00 11.35 14 G1HA024H14 600 19.2 13.6 12.00* - 11.50 14 G1HA024H14T 600 19.2 13.6 - 12.00* 11.60 - G1HD024 600 20.0 13.5 12.50* 12.50 11.70 525 17 G1NA030S17K 600 20.0 13.5 12.75* 12.75 11.75 H2RC018S06 675 21 G1NA030S21M 600 20.0 13.5 12.50* 12.50 11.75 14,17 G1UA024S14,17 600 19.2 13.0 12.00* 12.00 11.35 14,17 G2FD024(S,H)14,17 600 19.6 13.2 12.50* 12.50 11.60 17 G2FD030(S,H)17 600 20.0 13.5 12.60* 12.60 11.75 14 G2FD035(S,H)14 600 20.0 13.5 12.60* 12.60 11.75 14,17 G1FA024S14,17 750 23.0 16.4 11.80* 11.80 10.70 14 G1FA030S14 750 23.6 16.9 12.00* 12.00 11.00 14 G1FA036S14 750 24.2 17.6 12.00* 12.00 11.25 17,21 G1FA036S17,21 750 24.0 17.3 12.00* 12.00 11.10 14 G1HA024H14 750 19.2 13.6 12.00* - 10.90 14 G1HA024H14T 800 23.5 16.7 - 12.00* 10.90 14 G1HA036H14 800 24.6 17.5 12.00 - 11.35 - G1HD024 750 24.0 17.2 12.00* 12.00 11.05 - G1HD036 750 24.6 17.6 12.10* 12.10 11.35 H2RC024S06 650 17 G1NA030S17K 750 24.0 17.2 12.00* 12.00 11.15 850 21 G1NA030S21M 750 24.0 17.2 12.00* 12.00 11.15 14,17 G1UA024S14,17 750 23.0 16.4 11.80* 11.80 10.70 14 G1UA030S14 750 23.6 16.9 12.00* 12.00 11.00 14 G1UA036S14 750 24.2 17.6 12.00* 12.00 11.25 17,21 G1UA036S17,21 750 24.0 17.3 12.00* 12.00 11.10 14,17 G2FD024(S,H)14,17 750 23.6 16.9 12.00* 12.00 11.00 17 G2FD030(S,H)17 750 24.0 17.3 12.00* 12.00 11.10 14 G2FD035(S,H)14 750 24.0 17.3 12.10* 12.10 11.10 17 G2FD036(S,H)17 750 24.6 17.8 12.15* 12.15 11.35 14 G1FA030S14 1000 29.2 20.7 11.85* 11.85 10.80 14 G1FA036S14 1000 30.4 21.6 12.00* 12.00 11.10 17,21 G1FA036S17,21 1000 30.0 21.3 12.00* 12.00 11.00 17 G1FA048S17 1000 31.2 22.3 12.50* 12.50 11.45 21 G1FA048S21 1000 31.2 22.3 12.50* 12.50 11.35 14 G1HA036H14 1000 30.3 21.5 12.00* - 11.25 14 G1HA036H14 1000 30.2 21.4 - 12.00* 11.25 17 G1HA036H17 1000 30.4 21.9 12.00* - 11.35 17 G1HA036H17T 1000 30.5 22.0 - 12.00* 11.35 - G1HD036 1000 30.8 21.9 12.75* 12.75 11.25 17 G1NA030S17K 1000 30.2 21.4 12.00* 12.00 11.05 H2RC030S06 875 21 G1NA030S21M 1000 30.2 21.4 12.00* 12.00 11.05 1125 17 G1NA036S17L 1000 31.4 22.3 12.50* 12.50 11.45 14 G1UA030S14 1000 29.2 20.7 11.85* 11.85 10.80 14 G1UA036S14 1000 30.4 21.6 12.00* 12.00 11.10 17,21 G1UA036S17,21 1000 30.0 21.3 12.00* 12.00 11.00 17 G1UA048S17 1000 31.2 22.3 12.50* 12.50 11.45 21 G1UA048S21 1000 31.2 22.3 12.50* 12.50 11.35 17 G2FD030(S,H)17 1000 30.0 21.3 12.00* 12.00 11.00 14 G2FD035(S,H)14 1000 30.0 21.3 12.00* 12.00 11.00 17 G2FD036(S,H)17 1000 30.6 21.8 12.25* 12.25 11.20 21 G2FD036(S,H)21 1000 30.8 21.9 12.25* 12.25 11.25 21 G2FD042(S,H)21 1000 31.0 22.1 12.50* 12.50 11.35 17 G2FD046(S,H)17 1000 31.4 22.3 12.50* 12.50 11.45 For Notes See Page 9. Unitary Products Group 7 036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COIL MODEL COOLING UNIT MODEL CFM RANGE W RATED CFM NET MBH SEER SEER + TXV1 EER (Min.-max.) TOTAL SENS. W/O TXV 14 G1FA036S14 1200 33.6 23.4 11.50* 11.50 10.60 17,21 G1FA036S17,21 1200 33.0 23.0 11.25* 11.25 10.45 17 G1FA048S17 1200 35.0 24.4 12.00* 12.00 10.90 21 G1FA048S21 1200 34.0 25.2 12.00* 12.00 10.70 14 G1HA036H14 1150 33.5 23.8 12.00* - 10.75 14 G1HA036H14 1150 33.4 23.7 - 12.00* 10.75 17 G1HA036H17 1200 34.0 24.5 12.00* - 10.80 17 G1HA036H17T 1200 34.0 24.5 - 12.00* 10.80 21 G1 HA048H21 1200 34.0 24.8 12.00* - 10.70 21 G1HA048H21T 1200 33.3 24.3 - 12.00 10.70 - G1HD036 1200 34.0 23.7 11.80* 11.80 10.70 - G1HD048 1200 35.4 24.7 12.00* 12.00 11.00 H2RC036S06 1050 17 G1NA036S17L 1200 35.0 24.8 12.00* 12.00 10.90 1350 21 G1NA048S21 D 1200 35.0 24.8 12.00* 12.00 10.90 14 G1UA036S14 1200 33.6 23.4 11.50* 11.50 10.60 17,21 G1UA036S17,21 1200 33.0 23.0 11.25* 11.25 10.45 17 G1UA048S17 1200 35.0 24.4 12.00* 12.00 10.90 21 G1UA048S21 1200 34.0 25.2 12.00* 12.00 10.70 21 G1NA048S21 D 1200 35.0 25.2 12.00* 12.00 10.40 14 G2FD035(S,H)14 1200 33.0 23.0 11.25* 11.25 10.45 17 G2FD036(S,H)17 1200 33.8 23.6 11.50* 11.50 10.70 21 G2FD036(S,H)21 1200 34.2 23.8 12.50* 12.50 10.75 21 G2FD042(S,H)21 1200 34.6 24.1 12.00* 12.00 10.80 17 G2FD046(S,H)17 1200 35.0 24.4 12.00* 12.00 10.90 21,24 G2FD048(S,H)21,24 1200 36.0 25.1 12.10* 12.10 11.10 14 G1FA036S14 1235 33.4 25.0 - 11.50 10.65 17,21 G1FA036S17,21 1235 33.0 24.4 - 11.50 10.55 21 G1FA048S21 1235 35.0 25.9 - 12.00 10.70 - G1HD036 1235 33.4 24.7 ...
Эта инструкция также подходит к моделям:Кондиционеры - 12 SEER H*RC036S (265.25 kb)