Производитель: Freecom Technologies
Размер: 154.65 kb
Название файла: 9d91fe51-9708-4977-af84-b9edf2a1c155.pdf
|
Фрагмент инструкции
• Never place air conditioner near flammable materials. • Never put heavy objects on the unit. • To avoid damage and maintain proper operation, place indoor unit a minimum of 30 inches from curtains, furniture, blankets, loose material, or any other obstructions. Keep the unit a safe distance from stairs. • DO NOT use or operate the product in a confined space, such as a closet. • To avoid water leakage and damage: • Always operate the product on a solid, level surface. • Before moving the unit, always turn it off using the power on/off "I/O" button on the control panel and empty the water tank. Allow the unit to stand at least five (5) minutes. • DO NOT drop the unit or place it on its sides, back, top or front. Always keep the unit in its upright position. • To reduce the possibility of illness from excessive cooling: avoid direct, continuous exposure and never place the unit in a closed space occupied by persons incapable of operating the product properly. PRODUCT PARTS E CA FRONT VIEW D F N G Indoor Unit Outdoor Unit K M L L B A B Q P A. B. L C. Control Panel IO J H D. Horizontal Air Louver E. Air Outlet REAR VIEW F. Built-in Handle G. Air Filter H. Emergency Water Drain Tube I. Water Drain Plug J. Power Cord K. Flex Tube L. Caster Wheels M. Connector Cover N. Fan O. Drain Port (outdoor unit) P. Support Plate Q. Interlocking Fastener (for securing outdoor unit onto indoor unit) THE CONTROL PANEL 43 12 10 75 6 9 8 1. POWER ON/OFF "I/O" Easy push-button control switch to turn the unit ON and OFF. 2. MODE There are five different fan speed settings: • AUTO—Automatic fan speed with cooling setting by room temperature. • HI—High fan speed with cooling setting • MED—Medium fan speed with cooling setting • LO—Low fan speed with cooling setting. • FAN—Fan only (no cooling) 3. MODE LEDs Individual LED lights to show mode in operation. 4. COMPRESSOR LED Lights to show compressor is operating (cooling modes). 5. THERMO CONTROL The Thermo Control automatically defaults to a temperature of approximately 77.F when the unit is initially plugged in and started. Press right button to lower cooling setting; press left button to raise cooling setting. Each press of either button adjusts the temperature control by approximately 1.F. The temperature setting range is 68.F to 86.F. 6. DIGITAL DISPLAY WINDOW Digital display shows room temperature and "TIMER" setting, if applicable. 7. TIMER SET Adjustable 24 hour timer can be programmed to turn off or on after pre-selected time. 8. TIMER LED Individual LED lights to show if the timer is selected for "ON" or "OFF." 9. AUTO SWING Press to automatically begin (or stop) louvers moving up and down. 10. DRAIN WATER LED Lights to indicate water must be drained. 11. REMOTE CONTROL OPERATION SENSOR BEFORE USING IMPORTANT: Remove unit from packaging and discard clear, plastic wrapping. Place both units in upright position for a minimum of two hours before operating for the first time. CAUTION: Never use line/tube set to move, carry, or lift units. DO NOT place units near open flame or heat source. INSTALLATION Indoor Unit 1. Place indoor unit on a solid, level surface. Operating this unit on uneven or soft surfaces may cause vibration, noise, and possible water leakage. 2. Place indoor unit at least 30" from any draperies or other obstructions. Carefully push the unit on its castor wheels to desired location. 3. Determine a location for outdoor unit. If surface mounting, be sure outdoor unit can be placed at least 12" from any wall. Be sure the location is within reach of the tube set. The outdoor unit should be on a flat, level, solid surface or wall-mounted using the supplied mounting brackets. NOTE: Height location of outdoor unit must not exceed 6 feet (2 meters) above indoor unit. CAUTION: Do not operate unit without air filter properly in place. 4. Check that air filter is clean and properly installed. INSTALLATION (contd.) Outdoor Unit The outdoor unit can be either surface placed or wall-mounted. In either case, the outdoor unit must be fitted so the flexible tube set easily reaches the indoor unit. The flexible tube set can be routed through a window, door, or wall. For routing through a wall, please consult a certified contractor to perform interior and exterior hole cutting and disconnecting the tube set. 1. Determine an exterior position for outdoor unit. Double check and measure that the flexible tube set reaches the location of the indoor unit. For outdoor unit, determine whether the unit will be surface placed on a flat, solid, surface or wall mounted. NOTE: Height location of outdoor unit must not exceed 6 feet (2 meters) above indoor unit. 2. For routing tube set through a small window or wall, remove flexible tube set. See "Disconnecting Tube Set" for detailed information. There are two choices for installing the outdoor unit: surface placement and wall-mounting. See below for surface placing the outdoor unit. To wall-mount outdoor unit, please continue with "Wall-Moun...
Эта инструкция также подходит к моделям:Кондиционеры - RCS-S5000B (154.65 kb)
Кондиционеры - RCS-S3000T (154.65 kb)