|
Фрагмент инструкции
I IIIII IIIII IIIIIII M W A A START STO 3 SLEEP P1 2DAILY UNIT REMOTE Fig. 4 — Remote Control PROGRAMMING TIME PERIODS — The duct free system can be programmed to operate at desired levels. Be sure to set the clock before programming the system. • Increments of time are in 10 minute intervals. • The Timer Start/Stop indicator light on the unit is on when a time period is set. See Fig. 4. • The remote control displays the Start/Stop time of the time period that is closest to the current time. If the unit is ON, “STOP” and the time period is displayed. If the unit is OFF, “START” and the time period is displayed. I I I III I III I II III I I A A START STOP1 2 3 SLEEP DAILY IIIIIIIIIIIII I IIII MODE FAN SWEEP AA STAR T STOP 1 2 3 SLEEP D AILY TIMER SET CLEAR DELAY SENSE ROOM CLOCK IMPORTANT: Be sure to point the remote control toward the unit while pressing the TIMER or SET buttons. Setting Start/Stop Time — Timer feature is used to set unit operation Start/Stop times. Three different time periods up to 10 hours apart and within 24 hours can be programmed using this feature. 1. Slide down front cover of controller below ON/OFF but- Fig. 5 — Location of Clock Set Button ton. See Fig. 4. on Remote Control 4 2. Press the TIMER button. Each time the button is pressed the next Start or Stop set time appears on the display. See Fig. 6. 3. Press UP/DOWN button to set the time. 4. To set another time period, press the TIMER SET button to go to another time period and repeat steps 2 and 3 above. 5. Press the SET button to set the displayed time when done. See Fig. 7. NOTE: If changes are not made within 10 seconds, the remote control will return to its previous display. To correct an error, the programmed Timer settings must be cancelled and reentered. See Canceling Daily Timer section. Sleep Timer — The Sleep Timer function allows the desired temperature to be updated while the occupant is sleeping. The temperature in the room air gradually rises until this time period is exited. The unit will then return to the previous temperature set. To set the Sleep Timer, follow the steps below: 1. Slide down front cover of controller below ON/OFF button. See Fig. 4. 2. Press the TIMER button until Sleep function is reached. 3. Select the “SLEEP” timer period. 4. Press UP/DOWN button to set the start time and press Timer button to set stop time. 5. Press the SET button to set the display time when done. See Fig. 8. Setting Daily Timer — Time periods can be programmed to operate the system at set times during a 24-hour period. This timer function can be used for all 3 time periods and sleep period described above. NOTE: The daily timer operates only when there is a direct line of sight between the controller and the unit. 1. Slide down front cover of controller below ON/OFF button. See Fig. 4. 2. Press the TIMER button to select the time period that will be activated daily. 3. Press and hold the SET button until the word “DAILY” appears on the display. See Fig. 9. 4. Press the SET button again to confirm the daily operation for the selected time period. Be sure to point remote control toward the unit while pressing the SET button. STOP 1 STOP 2 START 3 STOP STAR T 1 STAR T 2 Fig. 6 — Timer Display Set Up on Remote Control TIMER INDICATOR IIII IIIIIIIIIIIIII MODE FAN SWEEP AA STAR T STOP 1 2 3 SLEEP DA ILY Fig. 7 — Set Timer Indicator on Remote Control Display SLEEP TIMER INDICATOR IIII IIIIIIIIIIIIII MODE FAN SWEEP AA START STOP 1 2 3 SLEEP DAI LY Fig. 8 — Sleep Timer Indicator on Remote Control Display Canceling Daily Timer — This function will cancel the selected Daily Timer program. 1. Slide down front cover of controller below ON/OFF button. See Fig. 4. 2. Press the TIMER button to select the time period that will be activated daily. 3. Press the SET button and hold until the word “DAILY” disappears on the display. 4. Press the SET button again to remove the daily operation from the selected time period. Be sure to point remote control toward the unit while pressing the SET button. Canceling Specific Start/Stop Time Period — One or more timers can be cancelled by performing the following steps: 1. Slide down front cover of controller below ON/OFF button. See Fig. 4. 2. Press the TIMER button and select desired Timer to cancel (1,2,3 or Sleep). 3. Press CLEAR button to cancel the selected Timer period. The Start/Stop times will disappear from the display. 4. Press the SET button to confirm the cancellation. Be sure to point remote control toward the unit while pressing the SET button. Canceling All Time Periods — All timers can be cancelled by performing the following steps: 1. Slide down front cover of controller below ON/OFF button. See Fig. 4. 2. Press the TIMER button. 3. Press and hold the CLEAR button until all Start/Stop times disappear from the display. 4. Check to be sure timer light is off on unit. 5. Press the SET button to confirm the cancellation. Be sure to point the remote control toward the unit while pressing ...
Эта инструкция также подходит к моделям:Кондиционеры - 38CG (174.86 kb)
Кондиционеры - CS018-030 (174.86 kb)