For test run, carry out the cooling operation firstly even during heating season. If heating operation is carried out firstly, it leads to the trouble of compressor. Then attention must be paid. Carry out the test run more than 5 minutes without fail. (Test run will be cancelled 18 minutes later automatically) The test run is started by pressing timer cancel button five times continuously. (Room type) To cancel the test run, press any button. 3) Settlement of outdoor unit Anchor the outdoor unit with a bolt and nut(o10mm) tightly and horizontally on a concrete or rigid mount. When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. In the case when the vibration of the unit is conveyed to the hose, secure the unit with an anti-vibration rubber. Bolt 4) Evaluation of the performance Operate unit for 15~20 minutes, then check the system refrigerant charge: 1. Measure the pressure of the gas side service valve. 2. Measure the temperature of the intake and discharge of air. 3. Ensure the difference between the intake temperature and the discharge is more than 8°C(46°F) (Cooling) or reversely (Heating). Tubing connection Refrigerant Outside ambient TEMP. The pressure of the gas side service valve. R-410A 35°C (95°F) 8.5~9.5kg/cm2G(120~135 P.S.I.G.) Discharge air Discharge temperature Intake temperature Discharge temperature Discharge air Intake temperature Service Manual 39 Operation Operation Function of control 1. MAIN UNIT FUNCTION • DISPLAY Operation Indicator • On while in appliance operation, off while in appliance pause • Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on) Sleep Timer Indicator • On while in sleep timer mode, off when sleep timer cancel or appliance operation pause Timer Indicator • On while in timer mode (on/off), off when timer mode is completed or canceled Defrost Indicator • Off except when hot start during heating mode operation or while in defrost control Cooling Mode Operation • When the intake air temperature reaches 0.5°C(32.9°F) below the setting temp, the compressor and the outdoor fan stop. • When it reaches 0.5°C(32.9°F) above the setting temp, they start to operate again. Compressor ON Temp . Setting Temp+0.5°C(32.9°F) Compressor OFF Temp . Setting Temp-0.5°C(31.1°F) • While in compressor running, operating with the airflow speed set by the remote control. While compressor is off fan operates at low speed regardless of the setting. Soft Dry Operation Mode • When the dehumidification operation input by the remote control is received, the intake air temperature is detected and the setting temp is automatically set according to the intake air temperature. 26°C(78.8°F) . Intake Air Temp . 25°C(77°F) 24°C(75.2°F) . Intake Intake Air Temp<26°C(78.8°F) . Intake Air Temp-1°C(30.2°F) 18°C(64.4°F) . Intake Intake Air Temp<24°C(75.2°F) . Intake Air Temp-0.5°C(31.1°F) Intake Air Temp<18°C(64.4°F) . 18°C(64.4°F) • While compressor off, the indoor fan repeats low airflow speed and stop. • While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification operation and 4-min compressor off repeat. Compressor ON Temp. . Setting Temp+0.5°C(32.9°F) Compressor OFF Temp. . Setting Temp-0.5°C(31.1°F) • In 10-min dehumidification operation, the indoor fan operates with the low airflow speed. Heating Mode Operation • When the intake air temp reaches +3°(37.4°F)…above the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on. Compressor ON Temp. . Setting Temp. Compressor OFF Temp. . Setting Temp.+3°C(37.4°F) • While compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C(68°F), when above 27°C(80.6°F) , it operates with the low or setting speed. When the indoor pipe temp is between 20°C(68°F) and 40 Multi type Air Conditioner Operation 27°C(80.6°F), it operates with Super-Low(while in sleep mode, with the medium airflow speed). • While compressor off, the indoor fan is off when the indoor pipe temp is below 33°C(91.4°F), when above 35°C(95°F) , it operates with the low airflow speed. • While in defrost control, the indoor is outdoor fans are turned off. Defrost Control(Heating) • Defrost operation is controlled by timer and sensing temperature of outdoor pipe. • The first defrost starts only when the outdoor pipe temperature falls below -6°C(21.2°F) after 35 minutes passed from starting of heating operation and more than 4 minutes operation of compressor. • Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature rises over 15°C(59°F) even before 12 minutes. • The second defrost starts only when the outdoor pipe temperature falls below -6°C(21.2°F) after 35 minutes passed from ending of the first defrost and more than 4 minutes operation of compressor. Fuzzy Operation • When any of operation mode is not selected li...

Эта инструкция также подходит к моделям:
Кондиционеры - A3UH363FA0, A3UC363FA0, AMNH093D4A0, AMNC093D4A0, AMNH123DEA0, AMNC123DEA0, AMNH093APM0, AMNC093APM0 (6.9 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории