Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Heat Controller, модель ASU18RLQ

Производитель: Heat Controller
Размер: 554.77 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


To select SWING Operation Press the SWING button (Fig. 6 T). The SWING Display (Fig. 7 b) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down. To stop SWING Operation Press the SWING button (Fig. 6 T) once again. The SWING Display (Fig. 7 b) will go out. Airflow direction will return to the setting before swing was begun. About Swing Operation During cooling/Dry mode : Swings between 1 and 3. During heating mode : Swings between 3 and 7. The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds. En-12 Cleaning the Intake Grille 1. Remove the Intake Grille. 1 Place your fingers at both lower ends of the grille panel, and lift forward; if the grille seems to catch partway through its movement, continue lifting upward to remove. 2 Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal. 2. Clean with water. Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth. 3. Replace the Intake Grille. 1 Pull the knobs all the way. 2 Hold the grille horizontal and set the left and right mounting shafts into the bearings at the top of the panel. 3 Press the place where the arrow on the diagram indicates and close the Intake Grille. CLEANING AND CARE Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord. Be sure the Intake Grille (Fig. 4 9) is installed securely. When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result. CAUTION! Cleaning the Air Filter 1. Open the Intake Grille, and remove the air filter. Lift up the air filter’s handle, disconnect the two lower tabs, and pull out. 2. Remove dust with a vacuum cleaner or by washing. After washing, allow to dry thoroughly in a shaded place. 3. Replace the Air Filter and close the Intake Grille. 1 Align the sides of the air filter with the panel, and push in fully, making sure the two lower tabs are returned properly to their holes in the panel. 2 Close the Intake Grille. (For purposes of example, the illustration shows the unit without Intake Grille installed.) Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of mild detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before reinstalling. If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increasing noise. During periods of normal use, the Air Filters should be cleaned every two weeks. When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel. When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner. Do not expose the unit body to liquid insecticides or hairsprays. When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half day to allow internal parts to dry thoroughly. Intake Grille Air filter handle Intake Grille Intake Grille Mounting shaft Knob Intake Grille Bearing Mounting shaft Knob Mounting shaft Knob En-13 CLEANING THE PLASMA AIR CLEANING FILTER CAUTION! WARNING! Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks on it. If the unit is not properly mounted, it could fall off and cause damage or injury. You can be injured if you touch the heat exchanger when removing or installing the plasma filter unit. Do not insert your fingers between the plasma filter unit and the heat exchanger. Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner. Electric shock may result. Regarding the Air Cleaning check function This function is illustrated by the flashing of the AIR CLEAN Indicator Lamp (green), indicating that the unit requires maintenance. After Air Cleaning Mode has been in use for approximately 400 hours, the AIR CLEAN Indicator Lamp (green) will begin to slowly flash (approximately once every 7 seconds). When this occurs, the unit requires maintenance. After Air Cleaning Mode has been in use for approximately 500 hours, the AIR CLEAN Indicator Lamp (green) will begin to flash quickly (approximately once every 3 seconds). At this point, Air Cleaning will cease functioning. Please carry out appropriate maintenance for the unit. Please carry out unit maintenance every 6 months. If a squeaking or chirping sound is heard, unit maintenance needs to be carried out, even if the AIR CLEAN Indicator Lamp (green) is not flashing. Cleaning the dust collection unit 1. Open the intake grille and remove the air filte...

Эта инструкция также подходит к моделям:
Кондиционеры - AOU15RLQ (554.77 kb)
Кондиционеры - AOU15RLQ (554.77 kb)
Кондиционеры - AOU18RLQ (554.77 kb)
Кондиционеры - ASU15RLQ (554.77 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории