Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Heat Controller, модель RADS-101H

Производитель: Heat Controller
Размер: 2.97 mb
Название файла: comfort-aire-rads-81h.pdf
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Isolate supply by taking power-plug out and con- tact a qualified service technician ! ! !! ! ! ! • Water may enter the unit and degrade the insulation. It may cause anelectric shock 3 Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual 4 IMPORTANTSAFETY INSTRUCTIONS Besuretheelectricalserviceisadequateforthemodelyouhave chosen. Thisinformationcanbefoundontheserialplate,which islocatedonthesideofthecabinetandbehindthegrille. Besuretheairconditionerisproperlygrounded. Tominimize shockandfirehazards,propergroundingisimportant. Thepower cordisequippedwithathree-pronggroundingplugforprotection againstshockhazards. Yourairconditionermustbeusedinaproperlygroundedwall receptacle.Ifthewallreceptacleyouintendtouseisnotadequately groundedorprotectedbyatimedelayfuseorcircuitbreaker, haveaqualifiedelectricianinstalltheproperreceptacle. Ensurethereceptacleisaccessibleaftertheunitinstallation. Donotrunairconditionerwithoutsideprotectivecoverinplace. Thiscouldresultinmechanicaldamagewithintheairconditioner. Donotuseanextensioncordoranadapterplug. WARNING Foryoursafety Donotstoreorusegasolineorotherflammablevaporsandliquidsin thevicinityofthisoranyotherappliance. Avoidfirehazardorelectricshock.Donotuseanextensioncordoran adaptorplug.Donotremoveanyprongfromthepowercord. WARNING ElectricalInformation NOTE Forsomemodels,thepower supplycordwiththisairconditioner containsacurrentdetectiondevice designedtoreducetheriskoffire. PleaserefertothesectionOperation ofCurrentDevicefordetails. Intheeventthatthepowersupply cordisdamaged,itcannotbe repaired-itmustbereplacedwitha cordfromtheProductManufacturer. , , Donot,underany circumstances,cut, remove,orbypass thegroundingprong. Powersupplycord with3-pronggroundingplug andcurrentdetectiondevice Operationof CurrentDevice (Applicabletotheunitadoptscurrentdetectiondeviceonly) Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord. Totestyourpower supplycorddothefollowing: 1.Pluginthe AirConditioner. 2. Thepowersupplycordwillhave TWObuttonsontheplughead.Pressthe TEST button,youwillnoticea clickastheRESET buttonpopsout. 3.PresstheRESET button,againyouwillnoticeaclickasthebuttonengages. 4. Thepowersupplycordisnowsupplyingelectricitytotheunit.(Onsomeproductsthisitalsoindicatedby alightontheplughead.) Donotusethisdevicetoturntheunitonoroff. AlwaysmakesuretheRESET buttonispushedinforcorrectoperation. Thepowersupplymustbereplacedifitfailsresetwheneitherthe TEST buttonispushed,oritcannotbe reset. A newonecanbeobtainedfromtheproductmanufacturer. Ifpowersupplycordisdamaged,itcannotberepaired.ItMUST bereplacedbyone NOTES: obtainedfromthe productmanufacturer. 4 Please refer to the section “Operation of Current Device” for details. Cooling operation Outdoor Temp: 64.4-109.4°F (18-43°C) (T1 Environment) 69.8-125.6°F (21-52°C) (T3 Environment) Indoor Temp: 62.6-89.6°F (17-32°C) (T1 Environment) 62.6-89.6°F (17-32°C) (T3 Environment) Heat operation Outdoor Temp: 23.0-75.2°F (-5-24°C) (T1 Environment) 19.4-75.2°F (-7-24°C) (T3 Environment) Indoor Temp: 32.0-80.6°F (0-27°C) (T1 Environment) 32.0-86.0°F (0-30°C) (T3 Environment) Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual 12 Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 13 Heat Controller, Inc. Room Air Conditioner with R-410A Owner’s Manual 14 104°F (40°C) Owner’s Manual Room Air Conditioner with R-410A Heat Controller, Inc. TROUBLESHOOTINGTIPS Beforecallingforservice,reviewthislist.Itmaysaveyoutimeandexpense. Thislistincludescommon occurrencesthatarenottheresultofdefectiveworkman-shipormaterialsinthisappliance. Problem Solution Wallplugdisconnected.Pushplugfirmlyintowalloutlet. Airconditioner doesnotstart Housefuseblownorcircuitbreakertri...

Эта инструкция также подходит к моделям:
Кондиционеры - RAD-123H (2.97 mb)
Кондиционеры - RADS-121H (2.97 mb)
Кондиционеры - RADS-81H (2.97 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории