Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Heat Controller, модель HALCYON P/N9359944058

Производитель: Heat Controller
Размер: 425.18 kb
Название файла: (OM)ABU18-24RULX.pdf

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


When the thermostat automatically lowered 2 °F every thirty minutes. When the has been rised a total of 4 °F, the thermostat setting at that thermostat has been lowered a total of 8 °F, the thermostat time is maintained until the set time has elapsed, at which setting at that time is maintained until the set time has elapsed, time the air conditioner automatically turns off. at which time the air conditioner automatically turns off. SLEEP timer setting SLEEP timer setting 4 °F 6 °F 8 °F 30 minutes 2 °F 1 hour 1 hour 30 minutes Set time Set time 1 hour 2 °F 4 °F MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable. CAUTION! How To Use the Main Unit Controls Do not press the MANUAL AUTO button with wet hands or pointed objects, otherwise an electric shock or malfunction may occur. Press the MANUAL AUTO button on the main unit control panel. To stop operation, press the MANUAL AUTO button once again. . When the air conditioner is operated with the controls on the Main unit, it will operate under the same mode as the AUTO mode selected on the remote control unit (see page 7). . The fan speed selected will be “AUTO” and the thermostat setting will be 74 °F. En-9 ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Vertical (up-down) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION VERTICAL SET button. Horizontal (right-left) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION HORIZONTAL SET button. Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button. Each time the button is pressed, the air direction range will change as follows: 1 2 3 4 5 6 7 Types of Air flow Direction Setting: 1,2,3,4 : During Cooling/Dry Modes 5,6,7 : * During Heating mode The remote control unit’s display does not change. Fig. 7 . Use the air direction adjustments within the ranges shown above. . The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected. During Cooling/Dry mode : Horizontal flow 1 * During Heating mode : Downward flow 7 . During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this period. Horizontal Air Direction Adjustment Press the AIR FLOW DIRECTION HORIZONTAL SET button. Each time the button is pressed, the air direction range will change as follows: 1 2 3 4 5 The remote control unit’s display does not change. RIGHT/LEFT air direction louvers Use the air direction adjustments within the ranges shown above. DANGER! Never place fingers or foreign objects inside the outlet ports, since the internal fan operates at high speed and could cause personal injury. . Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the UP/DOWN air direction flaps or RIGHT/LEFT air direction louvers. Attempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again. . During use of the Cooling and Dry modes, do not set the UP/DOWN air direction flaps in the Heating range (5 to 7) for long periods of time, since water vapor may condense near the outlet louvers and drops of water may drip from the air conditioner. . When used in a room with infants, children, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings. Example: When set to vertical air direction Example: When set to horizontal air direction Fig. 8 En-10 SWING OPERATION Begin air conditioner operation before performing this procedure. To select Vertical airflow SWING Operation Press the AIR FLOW DIRECTION VERTICAL SWING button. The SWING indicator lamp (VERTICAL SWING) (orange) will light. In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down. To Stop Vertical airflow SWING Operation Press the AIR FLOW DIRECTION VERTICAL SWING button once again. The SWING indicator lamp (VERTICAL SWING) will go out. Airflow direction will return to the setting before swing was begun. Example: When set to vertical swing About Swing Operation . The range of swing is relative to the currently set airflow . If the swing range is not as desired, use the remote con- direction. trol unit’s AIR FLOW DIRECTION VERTICAL SET button to Air flow direction set Range of swing 1 1 to 3 2 1 to 4 3 2 to 5 4 3 to 6 5 4 to 7 6 5 to 7 7 1 to 7 (All range) change the range of swing. . The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds. . During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flaps, in the Heating range (5 to 7) for long periods of time, since water vapor may condense near t...

Эта инструкция также подходит к моделям:
Кондиционеры - HALCYON P/N9359944058 (425.18 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории