Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Carrier, модель 33ZCFANTRM

Производитель: Carrier
Размер: 865.15 kb
Название файла: 33zc-1si.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . . . . . . . . . . . . . 1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Zone Controller Hardware . . . . . . . . . . . . . . . . . . . . . . . . 2 Field-Supplied Hardware . . . . . . . . . . . . . . . . . . . . . . . . . 2 • SPACE TEMPERATURE SENSOR • PRIMARY AIR TEMPERATURE SENSOR • SUPPLY AIR TEMPERATURE (SAT) SENSOR • RELATIVE HUMIDITY SENSOR • INDOOR AIR QUALITY (CO2) SENSOR Mount Zone Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 • LOCATION • MOUNTING Connect the Power Transformer. . . . . . . . . . . . . . . . . . 7 Connect Airflow Pickups . . . . . . . . . . . . . . . . . . . . . . . . . 7 Install Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 • SPACE TEMPERATURE SENSOR INSTALLATION • PRIMARY AIR TEMPERATURE SENSOR INSTALLATION • SUPPLY AIR TEMPERATURE (SAT) SENSOR INSTALLATION • INDOOR AIR QUALITY SENSOR INSTALLATION • HUMIDITY SENSOR (WALL-MOUNTED) INSTALLATION Remote Occupancy Contact. . . . . . . . . . . . . . . . . . . . . 26 Connect the Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Modulating Baseboard Hydronic Heating . . . . . . . . 26 Connect the CCN Communication Bus . . . . . . . . . . 26 • COMMUNICATION BUS WIRE SPECIFICATIONS • CONNECTION TO THE COMMUNICATION BUS START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-31 Perform System Check-Out . . . . . . . . . . . . . . . . . . . . . 29 Network Addressing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Initial Operation and Test. . . . . . . . . . . . . . . . . . . . . . . . 30 Airflow Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Fan and Heat Configuration and Test. . . . . . . . . . . . 30 CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-50 Points Display Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Modify Controller Configuration. . . . . . . . . . . . . . . . . 32 • ALARM LIMIT CONFIGURATION SCREEN • CONTROLLER IDENTIFICATION SCREEN • HOLIDAY CONFIGURATION SCREENS • LINKAGE COORDINATOR CONFIGURATION SCREEN • OCCUPANCY CONFIGURATION SCREEN • SET POINT SCREEN Service Configuration Selection Screen. . . . . . . . . 37 • AIRFLOW SERVICE CONFIGURATION SCREEN • TERMINAL SERVICE CONFIGURATION SCREEN • OPTIONS SERVICE CONFIGURATION SCREEN • SECONDARY DAMPER SERVICE CONFIGURATION SCREEN Maintenance Table Menu Screen . . . . . . . . . . . . . . . . 43 • LINKAGE MAINTENANCE TABLE • OCCUPANCY MAINTENANCE TABLE • ZONE AIR BALANCE/COMMISSIONING TABLE • ZONE MAINTENANCE TABLE SAFETY CONSIDERATIONS SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within design specifications. The equipment should be operated and serviced only by authorized personnel who have a thorough knowledge of system operation, safety devices and emergency procedures. Good judgement should be used in applying any manufacturer’s instructions to avoid injury to personnel or damage to equipment and property. Disconnect all power to the unit before performing maintenance or service. Unit may automatically start if power is not disconnected. Electrical shock and personal injury could result. If it is necessary to remove and dispose of mercury contactors in electric heat section, follow all local, state, and federal laws regarding disposal of equipment containing hazardous materials. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 4 PC 111 Catalog No. 533-355 Printed in U.S.A. Form 33ZC-1SI Pg 1 303 11-99 Replaces: New Book Tab 11a 13a GENERAL The zone controller is a single duct, fan powered, Variable Air Volume (VAV) terminal control with a factory-integrated controller and actuator. The zone controller maintains precise temperature control in the space by operating the terminal fan and regulating the flow of conditioned air into the space. Buildings with diverse loading conditions can be supported by controlling reheat or supplemental heat. The VAV Fan Terminal Zone Controller (33ZCFANTRM) provides dedicated control functions for series fan or parallel fan powered terminals, single duct terminals with 3 stages of heat, or as a primary controller for dual duct or zone pressure control applications. The Single Duct Air Terminal Zone Controller (33ZCVAVTRM) provides dedicated control functions for single duct terminals with modulating heat or up to 2 stages of heat. When the VAV Fan Terminal Zone Controller is used in conjunction with a secondary terminal and the 33ZCSECTRM secondary terminal zone controller, either dual duct or zone pressurization applications can be supported. Carrier’s Linkage system is an integrated combinat...

Эта инструкция также подходит к моделям:
Кондиционеры - 33ZCSECTRM (865.15 kb)
Кондиционеры - 33ZCVAVTRM (865.15 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории