Инструкция по эксплуатации Carrier, модель 30HH

Производитель: Carrier
Размер: 3.27 mb
Название файла: 30hh501055.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


ONE PANEL EACH SIDE, PANELS FRONT AND BACK OF COOLER SECTION, PANELS OVER FRONT OF COMPR., STEP CONT AND CONTROL CENTER SECTIONS. 3. SIDE PANELS PROVIDED WITH HOLES FOR CHILLED WATER PIPING. 4. TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUXILIARY WIRE ACCESS. 5. CONTROL BULB OF TEMPERATURE CONTROLLER TO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. 6 STANDARD CON T ROL VOLTAGE IS 230 VOLTS FOR 208, 230 a400V0LT UNITS FOR 460 a 575 VOLT UNITS STANDARD CONTROL VOLTAGE IS 115 VOLTS. LEFT SIDE VIEW FRONT VIEW Fig. 1 - 30HH,HJ015 Dimensional Data I.......! NOTES: I. CONDENSER AND ATTACHED PIPING AS SHOWN ARE FOR 30HH MODEL ONLY. 2 REMOVABLE PANELS FURN ISHED ON UNIT AS FOLLOWS:ONE PANEL EACH SIDE, PANELS FRONT AND BACK OF COOLER . TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUXILIARY WIRE ACCESS. . CONTROL BULB OF TEMPERATURE CONTROLLER TO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. LEFT SIDE VIEW FRONT VIEW Fig. 2 - 3QHH,HJ020 Dimensional Data 3 30HH,HJ INSTALLATION (Carrier) SEE NOTE I 2” FPT WATER OUTLET — CONDENSERS FOR 30HH030 - CONDENSERS FOR 30HH025 I 2 FPT WATER INLET—-... I 2 FPT WATER OUTLET— !"FPT WATER INLET NOTES: ! CONDENSER ANDATTACHED PIPING AS SHOWN ARE FOR 30 HH MODEL ONLY. 2. REMOVABLE PANELS FURNfSHEO ON UNIT AS FOLLOWS: ONE PANEL EACHSIDE, PANELS FRONT AND BACK OF COOLER SECTION, PANELS OVER FRONTOF COM PR., STEP CONT AND CONTROL CENTER SECTIONS. 4 TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUX ILIARY WIRE ACCESS. 5. CONTROL BULB OF TEMPERATURE CONTROLLER TO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. STANDARD CONTROL VOLTAGE IS23OV0LTS F0R208, 230 9 400V0LT UNITS. FOR 460 & 575 VOLT UNITS STANDARD CONTROL VOLTAGE IS 115 VOLTS. STEP CONTROLLER DISCH CONN.ÍHJ ONLY) HJ 025— I OD HJ030 — SAFETY THERMOSTAT RESET BUTTON 2 DIA. HOLE ELECTRIC CONN. IDE VIEW FRONT VIEW Fig. 3 - 30HH,HJ025,030 Dimensional Data NOTES: 1 CONDENSER AND ATTACHED PIPING AS SHOWN ARE FOR 30HH MODEL ONLY. 2 REMOVABLE PANELS FURNISHED ON UNIT AS FOLLOWS: ONE PANEL EACH SIDE, PANELS FRONT AND BACKOF COOLER SECTION, PANELS OVER FRONT OF COMPR, STEP CONT AND CONTROL CENTER SECTIONS. 3 SIDE PANELS PROVIDED WITH HOLES FOR CHILLED WATER PIPING. TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUXILIARY WIRE ACCESS. . CONTROL BULB OF TEMPERATURE CONTROLLER TO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. STANDARD CONTROL VOLTAGE IS 230 VOLTS FOR 208, 230 & 400 VOLT UNITS FOR 460 a 575 VOLT UNITS STANDARD CONTROL VOLTAGE IS 115 VOLTS. h* 5"— Ц 2 j I O.D. LIQUID LINE Fig. 4 - 30HH,HJ045 Dimensional Data 4 Carrier INSTALLATION 30HH,HJ 1. REMOVABLE PANELS FURN1 SHED ON UNIT AS FOLLOWS: ONE PANEL EACH S^DE, PANELS FRONT ANDBACK OF COOLER SECTION, PANELS OVER FRONT OF COMPR.,STEP CONT. AND CONTROL CENTER SECTIONS. 2. SIDE PANELS PROVIDED WITH HOLES FOR CHILLED WATER PIPING 3. TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUXILIARY WIRE ACCESS. 4 CONTROL BULB OF TEMPERATURE CONTROLLERTO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. 5. STANDARD CONTROL VOLTAGE IS 230VOLTS POR 208, 230 S 4C)OVOLT UNITS. FOR 460 a 575 VOLT UN ITS STANDARD CONTROL VOLTAGE IS 115 VOLTS. 2‘'FPT INLET(2) DENSER PIPING 3"DIA. HOLE FOR ELECTRICAL CONN. LOCATED IN REAR OF CIRCUsT BREAKER CABINET Г6[>1А.6- MTG HOLES LEFTSIDE VIEW SPACE REQD ; TO REMOVE : COOLER TUBES-EITHER END FRONT VIEW Fig. 5 - 30HH055 Dimensional Data NOTES: 1. CONDENSER AND ATTACHED PIPING AS SHOWN ARE FOR 30HH MODEL ONLY. 2. REMOVABLE PANELS FURNISHED ON UNIT AS FOLLOWS. ONE PANEL EACH SIDE, PANELS FRONT AND BACK OF COOLER SECTION, PANELS OVER FRONT OF COMPR., STEP CONT. AND CONTROL CENTER SECTIONS. 3. SIDE PANELS PROVIDED WITH HOLES FOR CHILLED WATER PIPING. 4. TWO HOLES PROVIDED IN REAR PANEL OF CONTROL BOX FOR CONTROL AND AUXILIARY WIRE ACCESS 5. CONTROL BULB OF TEMPERATURE CONTROLLER TO BE FIELD INSTALLED IN INLET CHILLED WATER LINE. 6. STANDARD CONTROL VOLTAGE IS 230 VOLTS FOR 208, 230 8 400 VOLT UNITS FOR 460 3575 VOLT UNITS STANDARD CONTROL VOLTAGE IS ¡15 VOLTS. -3’’DiA. HOLE FOR ELECTRICAL CONN LOCATED IN REAR OF CIRCUIT BREAKER CABINET LEFT SIDE VIEW FRONT VIEW Fig. 6 - 30HH,HJ065 Dimensional Data 5 30HH,HJ INSTALLATION PRELIMINARY SURVEY Before installation is started, a survey should be made to establish the procedures and materials required by installation personnel. See cover picture for typical unit. Storage Because of the sensitive control mechanisms and electrical devices incorporated in the 30HH,HJ units, they should not be exposed to the weather. Location Always locate the unit indoors. In order to prevent freezing, the unit must be located in a space where the temperature is at least 40 degrees. Space Requirements and Clearance Dimensions for the units are given in Table 1. These dimensions are useful in checking door clearances for moving the unit in and for determining space requ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории