• Remote control / display doesn’t work This is the answer • This is to protect the air conditioner. Wait until the air conditioner begins to operate. • This is the sound of refrigerant flowing inside the air conditioner. • Condensation occurs when the airflow from the air conditioner cools the room. • This may be a damp smell emitted by the wall, carpet, furniture or clothing in the room. • This is to remove smell emitted by the surroundings. • In COOL/DRY operation, moisture in the air condenses into water on the cool surface of outdoor unit piping that causes dripping. • This is to melt the frost which has accumulated on the outdoor unit (defrosting operating). This will take no longer than about 12 minutes. Water drips from the outdoor unit. Wait until this operation ends. (the power indicator will light up). (Frost will accumulates on the outdoor unit when the outdoor temperature is low and humidity is high.) • This is to prevent undesired cooling effect during heating operation. Please check • Has the circuit breaker been tripped? • Has the power plug been removed from the wall outlet? • Is the timer being used correctly? • Is the installation work slanted? • Is the front grille closed properly? • Has the temperature been set incorrectly? • Are the filters dirty? • Are the intake or outlet vents of the outdoor unit obstructed? • Are all windows and doors closed? • Batteries empty? • Batteries correctly inserted (+) and (–)? Call the Dealer Immediately If the following conditions occur, turn off and unplug the main power supply, and then call the dealer immediately. • Abnormal noise is heard during operation. • Water or foreign material gets into the remote control by mistake. • Water leak from the indoor unit. • Switches or buttons do not operate properly. • The circuit breaker switches off frequently. • Power supply cord and plug become unusually warm. 36 CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6 10 Installation Instructions Required tools for Installation Works 1. Philips screw driver 5. Spanner 9. Gas leak detector 13. Multimeter 2. Level gauge 6. Pipe cutter 10. Measuring tape 14. Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3. Electric drill, hole core drill (o70 mm) 7. Reamer 11. Thermometer 15. Vacuum pump 4. Hexagonal wrench (4 mm) 8. Knife 12. Megameter 16. Gauge manifold 10.1. Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before installation. • Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. • The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications. This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties only. The items to be followed are classified by the symbols: Symbol with background white denotes item that is PROHIBITED from doing. • Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6. Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8. When carrying out piping connection, take ca...

Эта инструкция также подходит к моделям:
Кондиционеры - CS-C7CKP (403.18 kb)
Кондиционеры - CS-C12CKP (403.18 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории