Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Lennox International Inc., модель WING

Производитель: Lennox International Inc.
Размер: 2.7 mb
Название файла: c6ecd39f-f28e-49a1-9f9d-29a5068721e0.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Lennox an international organisation with world wide distribution takes pride in supplying you with this product. CONTENTS PAGECONTENTS . PRODUCT RANGE 2-3 . SYSTEM CONFIGURATION 4 . GENERAL DESCRIPTION 5 . SPECIFICATIONS 6-9 . ELECTRICAL DATA 10-11 . ELECTRICAL CONNECTIONS 12-14 . INDOOR MOTOR FAN CHARACTERISTICS 15 . OPERATING LIMITS 16 . REFRIGERANT CONNECTIONS 17-19 . DIMENSIONS AND SETTING UP TEMPLATES OUTDOOR UNIT 20 . DESCRIPTION OUTDOOR UNIT 21-22 . ENTRANCE STANDARD/ OPTIONAL OUTDOOR UNIT 23 . DIMENSIONS AND SETTING UP TEMPLATES INDOOR UNIT 24 . INSTALATION AND MOUNTING 25 . OPTIONS26-27 MAINTENANCE 28 . POINTS TO KEEP IN MIND 29 1 PRODUCT RANGE COOLING ONLY R-407C LTX INDOOR UNIT IN COMBINATION, WITH AXIAL FAN OUTDOOR UNIT MODEL OUTDOOR UNIT INDOOR UNIT V / Ph / 50 Hz NOMINAL CAPACITY W COOLING ONLY COOLING ONLY NOMINAL CAPACITY KW 230V -1Ph 9.500 11.600 13.500 3,85 4,70 5,60 WING 3TFK WING 4TFK WING 5TFK KJF 3K KJF 4K KJF 5K LTX 3 LTX 5 LTX 5 230 V - 3Ph 400 V - 3Ph WING 3TFK WING 3TFK KJF 3K KJF 3K KJF 4K KJF 5K 230 V - 3Ph 400 V - 3Ph 230 V - 3Ph 400 V - 3Ph 230V-1Ph 7.350 3,06WING 2,8TFK KJF 2,8K LTX 3 WING 4TFK WING 5TFK LTX INDOOR UNIT IN COMBINATION, WITH CENTRIFUGAL FAN OUTDOOR UNIT MODEL OUTDOOR UNIT INDOOR UNIT V / Ph / 50 Hz NOMINAL CAPACITY W COOLING ONLY COOLING ONLY NOMINAL CAPACITY KW 230V -1Ph 9.100 12.100 14.000 3,86 5,17 7,00 WING 3CFK WING 4CFK WING 5CFK KCF 3K KCF 4K KCF 5K LTX 3 LTX 5 LTX 5 230 V - 3Ph 400 V - 3Ph WING 3CFK WING 3CFK KCF 3K KCF 3K KCF 4K KCF 5K 230 V - 3Ph 400 V - 3Ph 230 V - 3Ph 400 V - 3Ph 230V-1Ph 7.130 3,07WING 2,8CFK KCF 2,8K LTX 3 WING 4CFK WING 5CFK 2 PRODUCT RANGE HEAT PUMP HEAT PUMP R-22C LTX INDOOR UNIT IN COMBINATION, WITH AXIAL FAN OUTDOOR UNIT MODEL OUTDOOR UNIT INDOOR UNIT V / Ph / 50 Hz NOMINAL CAPACITY W COOLING ONLY NOMINAL CAPACITY KW HEAT PUMP COOLING ONLY HEAT PUMP 230V -1Ph 9.000 12.100 14.600 3,00 3,90 5,00 9.250 11.600 13.700 3,70 4,70 5,90 KJB 3 KJB 4 KJB 5 230 V - 3Ph 400 V - 3Ph KJB 3 KJB 3 KJB 4 KJB 5 230 V - 3Ph 400 V - 3Ph 230 V - 3Ph 400 V - 3Ph 230V-1Ph 7.800 2,607.350 3,06KJB 2,8 WING 3TB WING 4TB WING 5TB LTX 3 LTX 5 LTX 5 WING 3TB WING 3TB WING 2,8TB LTX 3 WING 4TB WING 5TB LTX INDOOR UNIT IN COMBINATION, WITH CENTRIFUGAL FAN OUTDOOR UNIT MODEL OUTDOOR UNIT INDOOR UNIT V / Ph / 50 Hz NOMINAL CAPACITY W COOLING ONLY NOMINAL CAPACITY KW HEAT PUMP COOLING ONLY HEAT PUMP 230V -1Ph 10.220 13.500 17.400 3,40 4,33 6,40 9.100 12.100 14.000 3,86 5,17 7,00 KCB 3S KCB 4S KCB 5S 230 V - 3Ph 400 V - 3Ph KCB 3S KCB 3S KCB 4S KCB 5S 230 V - 3Ph 400 V - 3Ph 230 V - 3Ph 400 V - 3Ph 230V-1Ph 8.150 2,777.130 3,07KCB 2,8S WING 3CB WING 4CB WING 5CB LTX 3 LTX 5 LTX 5 WING 3CB WING 3CB WING 2,8CB LTX 3 WING 4CB WING 5CB 3 SYSTEM CONFIGURATION (INDOOR UNIT) IMPORTANT Prior of making the electrical connections, set the switch for heat pump unit or for cooling only unit. This unit is valid for operating as a cold only or heat pump application. The unit should be configured prior to making the electrical connections, by setting the configuration switch as follows: MODEL SWITCH 1 2 COOLING ONLY (*) OFF ON HEAT PUMP ON ON ON OFF Switch 2 Switch 1 (*) Configuration from factory.. Check page 8 for more information about the situation of this switch. NOTE: If errors are made during the configuration of the system, switch off the main power supply, set configuration switch in the correct position and then switch the power on. 4 GENERAL DESCRIPTION INDOOR UNIT LTX OUTDOOR UNITKCF/KCB OUTDOOR UNIT KJF/KJB CABINE The outdoor unit is made on electrozinced steel with epoxy painted finish, able to work outdoors under the worst conditions. its dimensions and features allow the unit to be positioned in almost any location. It incorporate thermal acoustic insulation. The indoor unit is finished in a decorative plastic with thermal acoustic insulation. HEAT EXCHANGER Made of cooper tubes and aluminium fins. Coils have been designed and manufactured to ensure maximum efficiency. The L shaped outside unit heat exchanger makes this unit compact an highly efficiency. COMPRESSOR An hermetically sealed compressor, with internal thermal protection. It is mounted on vibration absorbent blocks both on the inside and outside, statically an dynamically balanced. In all cases the compressors are acoustically isolated, resulting in low noise. FANS The indoor units includes centrifugal motor fan of three speed, with exceptional features on noise level Depending on outdoor type, it includes one or two axial motor fan (units KJF/KJB), or one centrifugal fan (units KCF/ KCB),with exceptional features in noise level and flow . The ceiling air conditioner SPLIT, on version cooling only and heat pump, are units air condensed. The indoor unit with direct air supply, realise function of cooling , heating dehumidification, cleaning air of the sites. Also the option to incorporate with maximum facilities a heating resistance on units cooling only and also on heat pump units. The indoor unit ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории