|
Фрагмент инструкции
1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478 NFPA National Fire Protection Association Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9901 Telephone: (800) 344-3555 Fax: (617) 984-7057 Manufactured under the following U.S. Patent numbers: 5,485,878; 5,301,777; 5,002,116; 4,924,934; 4,875,520; 4,825,936; 4,432,409 Manual 2100-400 Page 1 WALL MOUNT GENERAL INFORMATION HEAT PUMP WALL MOUNT MODEL NOMENCLATURE CONTROL MODEL NUMBER WL42 3 – A 10 X N X X X A MODULES (See Chart Below) CAPACITY COIL OPTIONS 42 -3 1/2 Ton X -Standard 48 -4 Ton REVISIONS 1 -Phenolic Coated Evaporator 60 -5 Ton COLOR OPTIONS 2 -Phenolic Coated Condenser X -Beige (Standard) 3 -Phenolic Coated Evaporator 1 -White and Condenser 2 -Mesa Tan KW VOLTS & PHASE 4 -Buckeye Gray OUTLET OPTIONS VENTILATION OPTIONS A -230/208/60/1 5 -Desert Brown X -Front (Standard) X -Barometric Fresh Air Damper (Standard) B -230/208/60/3 6 -Dark Bronze B -Blank-off Plate C -460/60/3 M -Motorized Fresh Air Damper V -Commercial Ventilator Motorized with Exhaust FILTER OPTIONS E -Economizer (Internal) - Fully X -One Inch Throwaway Modulating with Exhaust (Standard) R -Energy Recovery Ventilator W -One Inch Washable Motorized with Exhaust P -Two Inch Pleated NOTE: All vent options are without exhaust capability. May require separate field supplied barometric relief in building. TABLE 1 ELECTRIC HEAT TABLE Models WL423-A WL484-A WL602-A WL423-B WL484-B WL602-B WL423-C WL484-C WL602-C 240-1 208-1 240-3 208-3 460-3 KW A BTU A BTU A BTU A BTU A BTU 5 20.8 17050 18.1 12800 9 21.7 30600 18.7 23030 10.8 30700 10 41.6 34130 36.2 25600 15 62.5 51200 54.0 38400 36.2 51200 31.2 38400 17.3 47000 Manual 2100-400 Page 2 FIGURE 1 UNIT DIMENSIONS Manual 2100-400 Page 3 Mode l Widt h (W) Dept h (D ) Heig h t (H ) Suppl y Retur n E F G I J K L M N O P Q R S T A B C B WL4 2 WL4 8 WL6 0 42.07 5 22.43 2 84.87 5 9.8 8 29.8 8 15.8 8 29.8 8 43.8 8 19.1 0 31.6 6 30.0 0 32.6 8 26.9 4 34.6 9 32.4 3 3.3 7 42.8 8 23.8 8 10.0 1.4 16.0 1.8 BACK VIEW LEFT SIDE VIEW FRONT VIEW MIS-1286 TABLE 2 ELECTRICAL SPECIFICATIONS Model SINGLE CIRCUIT DUAL CIRCUIT Rated Volts & Phase No. Field Power Circuits • Minimum Circuit Ampacity • Maximum External Fuse or Circuit Breaker • Field Power Wire Size • Ground Wire Size • Minimum Circuit Ampacity • Maximum External Fuse or Ckt. Breaker • Field Power Wire Size • Ground Wire Size CKT A CKT B CKT A CKT B CKT A CKT B CKT A CKT B WL423-A00, A0Z A05 A10 A15 230/208-1 1 1 1 1 or 2 35 35 59 85 50 50 60 90 8 8 6 4 10 10 10 8 N/A N/A N/A 56 N/A N/A N/A 26 N/A N/A N/A 60 N/A N/A N/A 30 N/A N/A N/A 6 N/A N/A N/A 10 N/A N/A N/A 10 N/A N/A N/A 10 WL423-B00, B0Z B09 B15 230/208-3 1 1 1 24 34 52 35 35 50 8 8 6 10 10 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WL423-C00, C0Z C09 C15 460-3 1 1 1 13 17 26 15 20 30 14 12 10 14 12 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WL484-A00, A0Z A05 A10 A15 230/208-1 1 1 1 1 or 2 36 36 59 85 50 50 60 90 8 8 6 4 10 10 10 8 N/A N/A N/A 59 N/A N/A N/A 26 N/A N/A N/A 60 N/A N/A N/A 30 N/A N/A N/A 6 N/A N/A N/A 10 N/A N/A N/A 10 N/A N/A N/A 10 WL484-B00, B0Z B09 B15 230/208-3 1 1 1 25 34 52 35 35 60 8 8 6 10 10 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WL484-C00, C0Z C09 C15 460-3 1 1 1 13 17 26 15 20 30 14 12 10 14 12 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WL602-A00, A0Z A05 A10 A15 230/208-1 1 1 1 1 or 2 44 44 55 85 60 60 60 90 8 8 6 4 10 10 10 8 N/A N/A N/A 59 N/A N/A N/A 26 N/A N/A N/A 60 N/A N/A N/A 30 N/A N/A N/A 6 N/A N/A N/A 10 N/A N/A N/A 10 N/A N/A N/A 10 WL602-B00, B0Z B09 B15 230/208-3 1 1 1 32 34 52 45 45 60 8 8 6 10 10 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WL602-C00, C0Z C09 C15 460-3 1 1 1 16 17 26 20 20 30 12 12 10 12 12 10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A . Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. . Based on 75° C copper wire. All wiring must conform to NEC and all local codes. . These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), article 310 for power conductor sizing. CAUTION: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table 310 regarding Ampacity Adjustment Factors when more than 3 conductors are in a raceway. Manual 2100-400 Page 4 SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by...
Эта инструкция также подходит к моделям:Кондиционеры - WL484 (274.93 kb)
Кондиционеры - WL602 (274.93 kb)