Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Bard, модель WA4823

Производитель: Bard
Размер: 301.15 kb
Название файла: c6d7618b-5247-4579-ab42-2e567eca841f.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


ANSI/NFPA 70 Standard for the Installation................... ANSI/NFPA 90A of Air Conditioning and Ventilating Systems Standard for Warm Air .......................... ANSI/NFPA 90B Heating and Air Conditioning Systems Load Calculation for .............................. ACCA Manual J Residential Winter and Summer Air Conditioning Duct Design for Residential................... ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection For more information, contact these publishers: ACCA Air Conditioning Contractors of America 1712 New Hampshire Ave. N.W. Washington, DC 20009 Telephone: (202) 483-9370 Fax: (202) 234-4721 ANSI American National Standards Institute 11 West Street, 13th Floor New York, NY 10036 Telephone: (212) 642-4900 Fax: (212) 302-1286 ASHRAE American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. 1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478 NFPA National Fire Protection Association Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9901 Telephone: (800) 344-3555 Fax: (617) 984-7057 Manufactured under the following U.S. patent numbers: 5,485,878; 5,301,777; 5,002,116; 4,924,934; 4,875,520; 4,825,936; 4,432,409 Manual 2100-348 Page 1 WALL MOUNT GENERAL INFORMATION AIR CONDITIONING WALL MOUNT MODEL NOMENCLATURE CONTROL MODULES MODEL NUMBER WA 60 2 3 A 10 X N X X X A CAPACITY COIL OPTIONS 60 - 5 Ton X -Standard 1 -Phenolic Coated Evaporator COLOR OPTIONS 2 -Phenolic Coated Condenser REVISIONS KW X -Beige (Standard) 3 -Phenolic Coated Evaporator FEATURE CODE 1 -White and Condenser 3 -3 ton air openings 2 -Mesa Tan on 5 ton cabinet VOLTS & PHASE 4 -Buckeye Gray OUTLET OPTIONS 2 -2 ton air openings A -230/208/60/1 VENTILATION OPTIONS X -Front (Standard) on 5 ton cabinet B -230/208/60/3 B -Blank-off Plate FILTER OPTIONS N -No Filter WA4823, WA6023, WA602N models ONLY X -One Inch Throwaway Filter WA4822, WA6022 models ONLY W -One Inch Washable Filter WA4822, WA6022 models ONLY P -Two Inch Pleated Filter WA4822, WA6022 models ONLY NOTE: All vent options are without exhaust capability. May require separate field supplied barometric relief in building. Model WA602N is identical to Model WA6023. All references in this manual to WA6023 apply to WA602N also. TABLE 1 ELECTRIC HEAT TABLE Models WA6023A ONLY WA6023B ONLY 240V-1 208V-1 240V-1 208V-1 KW AMPS BTUH AMPS BTUH AMPS BTUH AMPS BTUH 5.0 20.8 17,050 18.1 12,800 -------- ---- ---- 9. 0 -------- ---- ---- 21. 7 30,600 18.7 23,030 10.0 41.6 34,130 36.2 25,600 -------- ---- ---- WA4822A, WA4822B, WA4823A, WA4823B, WA6022A, WA6022B are not approved for use with electric heat. Manual 2100-348 Page 2 FIGURE 1 UNIT DIMENSIONS WA602N, WA6023, WA4823 ONLY Manual 2100-348 Page 3 MIS-1348 FIGURE 2 UNIT DIMENSIONS WA6022, WA4822 ONLY Manual 2100-348 Page 4 MIS-1442 TABLE 2 ELECTRICAL SPECIFICATIONS Manual 2100-348 Page 5 Mode l SINGL E CIRCUI T DUA L CIRCUI T Rate d Volts & Phas e No . Fiel d Powe r Circuit s • Minimu m Circui t Ampacit y • Maximu m Externa l Fus e o r Ckt . Breake r • Fiel d Powe r Wir e Siz e • Groun d Wir e Siz e • Minimu m Circui t Ampacit y • Maximu m Externa l Fus e o r BreakerCkt . • Fiel d Powe r Wir e Siz e Groun d Wir Siz CK T A CK T B CK T A CK T B CK T A CK T B CK T A CK T B WA4822A00 , A0 Z 230/208- 1 1 3 8 5 0 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WA4822B00 , B0 Z 230/208- 3 1 2 6 3 5 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WA4823A00 , A0 Z 230/208- 1 1 3 8 5 0 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WA4823B00 , B0 Z 230/208- 3 1 2 6 3 5 8 1 0 N/ A N/ A N/ A N/ A N/ A N/ N/ N/ WA6022A00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WA6022B00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ WA6023A00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WA6023B00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ WA602NA00 , A0 Z A0 5 A1 0 230/208- 1 1 1 1 4 4 4 4 5 5 6 0 6 0 6 0 8 8 6 1 0 1 0 1 0 N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ N/ N/ N/ WA602NB00 , B0 Z B0 9 230/208- 3 1 1 3 2 3 4 4 5 4 5 8 8 1 0 1 0 N/A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ A N/ N/ N/ N/ N/ N/ . Maximum size of the time delay fuse or HACR . Based on 75° C copper wire. All Wiring must conform to NEC and all . These “ minimum Circuit Ampacity” values are to be used for sizing the Refer to the National Electric Code (latest revision), article CAUTION: When more than one field power conductor circuit is run through Pay special attention to note 310 regarding Ampacity Adjustment SHIPPING DAMAGE Upon receipt of equipment, the...

Эта инструкция также подходит к моделям:
Кондиционеры - WA6022 (301.15 kb)
Кондиционеры - WA6023 (301.15 kb)
Кондиционеры - WA602N (301.15 kb)
Кондиционеры - WA4822 (301.15 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории