Installing a TRSA CRU
Note: Whenever you handle a Token-Ring ServerNet adapter (TRSA) CRU, you should follow
standard operating practices to avoid damage to the equipment.
1 Put on the electrostatic discharge (ESD) wriststrap and attach the grounding clip to the
antistatic mat.
2 Place the package containing the TRSA CRU on the antistatic mat.
3
Caution: When opening the packing container, be careful not to cut into the ESD
protective bag.
Open the packing container and remove the TRSA CRU.
4 Disconnect the grounding clip of your ESD wriststrap from the antistatic mat and connect it
to an exposed, unpainted metal surface on the TRSA CRU.
5 Grasp the TRSA CRU by its ejector in one hand, support the bottom edge of the TRSA CRU
with the other hand, and carry the TRSA CRU to the service side of the system enclosure
and set it down.
Note: The TRSA CRU weights 6.75 pounds (3 kilograms).
6 Disconnect the grounding clip of your ESD wriststrap from the TRSA CRU and connect it to
an exposed, unpainted, metal surface on the service side of the system enclosure, such as
the processor multifunction (PMF) CRU or I/O multifunction (IOMF) CRU ventilation holes.
The figure shows how to connect the grounding clip to the ventilation holes on the PMF CRU
or IOMF CRU .
7 With the ejector on the TRSA CRU in the full-open position, grasp the TRSA CRU by its
ejector with one hand and support the bottom edge of the TRSA CRU with the other hand.
Hold the TRSA CRU so that its ejector is at the top and insert the TRSA CRU into the upper
part of the carrier.
8
Caution: Apply equal pressure to both the top and bottom of the TRSA CRU when
pushing it into the slot to avoid damaging the connector pins. If pins are damaged, both the
TRSA CRU and the backplane (or enclosure) must be replaced.
Push the TRSA CRU to the rear of the slot, but don't force the TRSA CRU into the slot.
The figure shows how to install an TRSA CRU.
9 Press the blue-green tab on the TRSA CRU ejector and latch the ejector to seat the TRSA
CRU against the backplane.
10 Disconnect the grounding clip of your ESD wriststrap from the enclosure.
11 Connect the communications cable to the TRSA CRU. You can connect an RJ-45 connector
to the Token-Ring Connector UTP port or a DB-9 connector to the Token-Ring Connector
STP port.
Note: You can use only one connector at a time. The top two ports are non-functional for
the G05.00 and G06.00 RVUs.


...