Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Dialogic, модель SS7G2X

Производитель: Dialogic
Размер: 828.92 kb
Название файла: f49a6806-aa75-470f-8141-b4ad02790a43.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If RESET is set to Y, all configuration data is removed. If SYSTYPE is set, the systems operating mode changes after restart. Possible operation modes are: • DSC – Digital Signaling Conveter • SGW – SIGTRAN Signaling Gateway • SIU – Signaling Interface Unit Syntax MNRSI:[RESTART=,][RESET=Y,][SYSTYPE=,]; Prerequisites • SYSTYPE can only be set to system types that have been licensed for the unit. See the CNSYP command. Note: SIU is always licensed. Attributes PROMPT Examples MNRSI; MNRSI:RESET=Y; MNRSI:SYSTYPE=SGW; Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4 6.10 Measurement Commands The measurement commands include: • MSC7P -Measurements SS7 Print • MSEPP -Measurement Ethernet Port Print • MSPCP -Measurements PCM Print • MSSLP -Measurements SIGTRAN Link Print • MSSYP -Measurements System Print Chapter 6 Command Definitions 6.10.1 MSC7P – Measurements SS7 Print Synopsis This command prints traffic measurements for SS7 signaling links. The measurements are cumulative between system startup and the next time the measurements are reset. The fields have the following meanings: • C7LINK - SS7 signaling Link. • OOSDUR - Duration that the link was not in service. This field is not currently supported. • RXNACK - Number of negative acknowledgements received. Note: RXNACK is not applicable for M2PA SS7 links and is set to 0. See the MSSLP command description for SNLINK measurements. • RXMSU - Number of message signaling units octets received. • RXOCT - Number of SIF and SIO octets received. • TXMSU - Number of message signaling units octets transmitted. • TXOCT - Number of SIF and SIO octets transmitted. • RTXOCT - Octets retransmitted. Note: RTXOCT is not applicable for M2PA SS7 links and is set to 0. See the MSSLP command description for SNLINK measurements. • NCONG - Congestion counter. • PERIOD - Time since measurements on the route were last reset. Specified in hours, minutes and seconds. • ALIGN - Number of failed signaling link alignment attempts • SUERR - Number of signal units in error • TBUSY - Duration of local busy condition • TCONG - Duration of link congestion • NDISCARD - Number of MSUs discarded due to congestion • NEVENT - Number of congestion events leading to MSU discard Syntax MSC7P:[PAGE=,][C7LINK=,][RESET=,]; Prerequisites • If specified, the SS7 signaling link must be initiated and unblocked. Attributes None Examples MSC7P:C7LINK=1; MSC7P; Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4 Output Format SS7 Link Traffic Measurements (Page 1 of 2) C7LINK OSSDUR RXNACK RXMSU RXOCT TXMSU TXOCT RTXOCT NCONG PERIOD 1 0 0 188 4136 188 4136 0 0 00:46:39 2 0 0 188 4136 188 4136 0 0 00:46:39 3 0 0 0 0 0 0 0 0 00:46:39 EXECUTED SS7 Link Traffic Measurements (Page 2 of 2) C7LINK ALIGN SUERR TBUSY TCONG NDISCARD NEVENT PERIOD 1 0 0 0 0 0 0 00:46:39 2 0 0 0 0 0 0 00:46:39 3 92 0 0 0 0 0 00:46:39 EXECUTED Chapter 6 Command Definitions 6.10.2 MSEPP – Measurement Ethernet Port Print Synopsis This command prints the traffic measurements for each Ethernet port on the system taken over a period of time. The meaning of each field in the output is as follows: • ETH - Ethernet port number in the range 1 to 4, where: — ETH=1 corresponds to physical port ENET 1 — ETH=2 corresponds to physical port ENET 2 — ETH=3 corresponds to physical port ENET LNK A — ETH=4 corresponds to physical port ENET LNK B • RXKBTYE - Number of kilobytes of data received (in kilobytes) • RXPKT - Number of packets of data received • RXERR - Number of receive errors detected • RXDROP - Number of received packets dropped by the device driver during the measurement period • TXKBTYE - Number of kilobytes of data transmitted (in kilobytes) • TXPKT - Number of packets of data transmitted • TXERR - Number of transmit errors detected • TXDROP - Number of transmit packets • PERIOD - The period over which the measurement was taken • RXFIFO - The number of FIFO buffer errors received • RXFRAME - The number of packet framing errors received • RXCOMP - The number of compressed packets received • RXMULT - The number of multicast frames received • TXFIFO - The number of FIFO buffer error transmitted • TXCOLLS - The number of collisions detected on the transmit side • TXCARRIER - The number of carrier losses detected on the transmit side • TXCOMP - The number of compressed packets transmitted Note: Values are reset using the RESET parameter. MSEPP:RESET=Y; resets the measurement values to 0. Syntax MSEPP:[RESET=,][PAGE=,]; Prerequisites None. Attributes None. Examples MSEPP:RESET=YES,PAGE=2; MSEPP; Dialogic® SS7G2x Signaling Server SGW Mode User Manual Issue 4 Output Format Ethernet Port Measurements (Page 1 of 2) ETH RXKBYTE RXPKT RXERR RXDROP TXKBYTE TXPKT TXERR TXDROP PERIOD 1 0 0 0 0 0 0 0 0 16:34:41 2 96324 135705 0 4204E5 28169 4444 0 0 16:34:41 3 0 0 0 0 0 0 0 0 16:34:41 4 3760 3273 0 33615 12503 3455 0 0 16:34:41 EXECUTED Ethernet Port Measurements (Page 2 of 2) ETH RXFIFO RXFRAME RXCOMP RXMULT TXFIFO TXCOLLS TXCARRIER T...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории