Инструкция по эксплуатации AMX, модель HDDs in MMS Servers

Производитель: AMX
Размер: 411.06 kb
Название файла: 93-2178-250.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Only HDDs provided by AMX can be used as replacements in MMS servers, and in order to replace a HDD in an MMS server, the drive must be installed and authenticated according to the steps outlined in this document. • The MMS-01S, MMS-02S, MMS-04S and MMS-12S servers all utilize 250GB hard drives, and require the MMS-HDD250G 250GB drive (FG 2178-250) for replacements. • The MMS-900 server utilizes 300GB hard drives, and requires the MMS-HDD300G 300GB drive (FG 2178-300) for replacements. There are several operations that are required to successfully replace an HDD in a MMS server, all off which are described in this document: 1. The physical removal of the damaged HDD, and the subsequent installation of the replacement HDD. 2. A rebuild of the RAID array on the new HDD (required in order to add it to the server’s RAID array). 3. Authentication of the new HDD with the MMS server. Note that before the HDD can be authenticated to the server it must first be added into the array. Note: The MMS-01S server does not utilize a RAID disk-drive system. In this case there is no need to rebuild the array (as described below), but the replacement HDD still needs to be authenticated (see “Step 4: Authenticate the New HDD” below). Step 1: Identify the Drive That Needs To Be Replaced To identify the drive that needs to be replaced, you’ll use the server’s built-in Disk Management Utility tool. This requires that you have a PC connected to the MMS: • If you intend to connect to the MMS via a LAN connection, verify that the PC is communicating properly with the network. • Use an RJ-45 twisted pair cable to connect the Ethernet port on the MMS to the LAN that your PC is on. Once you have established communication between the MMS server and your PC, you’ll use your web browser to access the server’s Disk Management Utility interface to see which port has failed. You’ll need this information to identify the physical HDD that needs to be pulled from the unit and replaced: 1. Launch a web browser (i.e. Internet Explorer). 2. Enter the IP address of the target MMS server in the address bar (example: You can use the WinMAX program to determine the server’s IP address (displayed in the System Information tab). Don’t forget to include the port number. Note: If you are using Mozilla as your browser, you’ll need to override the security that blocks port 1080. To unblock port 1080, add the following line (located at /usr/lib/mozilla/defaults/pref/all.js): pref(“network.security.ports.banned.override”,”1080”) 3. Press Enter to open the Disk Management Utility - Home Page (FIG. 1). FIG. 1 Disk Management Utility - Home page 4.Click on the Configure tab at the top of the screen to access the Configure page (FIG. 2) which lists all drives in each array and their status. If a drive has failed, it will be labeled “Degraded” rather than “OK”. Degraded FIG. 2 Disk Management Utility - Configure page 5. Note the Port Number of the Degraded drive, and determine which physical drive needs to be replaced in the server, based on the charts in FIG. 3: PORT 0 PORT 1 PORT 2 PORT 3 PORT 2 PORT 5 PORT 8 PORT 11 PORT 1 PORT 4 PORT 7 PORT 10 PORT 0 PORT 3 PORT 6 PORT 9 PORT 0 PORT 6 PORT 12 PORT 18 PORT 1 PORT 7 PORT 13 PORT 19 PORT 2 PORT 8 PORT 14 PORT 20 PORT 3 PORT 9 PORT 15 PORT 21 PORT 4 PORT 10 PORT 16 PORT 22 PORT 5 PORT 11 PORT 17 PORT 23 MMS-04S (front) MMS-12S (front) MMS-900 (front) FIG. 3 Port to HDD correlation -MMS-04S, MMS-12S and MMS-900 servers Also note that the LED on the degraded drive should blink to indicate that it needs to be replaced. Once you have determined which drive needs to be replaced, you can proceed to physically removing the bad drive, and installing the replacement drive (see reverse). Step 2: Physical Removal and Replacement of the Drives 1 Push tab to the right to unlock the hinged front panel hinge Flip the hinged front panel out, and use it as a handle to pull the 2 drive/tray assembly out of its slot. FIG. 4 Removable drive/tray assembly (front panel) 1. Remove the faceplate from the front panel of the server. 2. Remove the damaged HDD. Each HDD is mounted in a tray that slides in and out of the server. To remove the drive/tray assembly (FIG. 4): a. Push the tab on the front of the drive tray to the right to unlock the hinged front panel. Flip the hinged panel out and use it as a handle to gently pull the drive/tray assembly out of its slot. b. Remove the drive from the drive tray. The drive is secured to the tray with four screws on the bottom panel. 3. Install and secure the replacement drive into the drive tray. 4. Slide the replacement drive/tray assembly fully into the slot, and push the hinged front panel back into its locked position. The LEDs on the front of the HDD should light to indicate that it has been connected and is communicating properly. 5. Replace the faceplate on the server. Step 3: Rebuild the RAID Array Once the new HDD has been installed, the drive must be added to th...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории