Инструкция по эксплуатации Agilent Technologies, модель B2200A

Производитель: Agilent Technologies
Размер: 1.34 mb
Название файла: B2200_user_gd_2.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


b. Press the right/left arrow key to move the cursor on the input port number (01 to 14) that will be set to the input ground port. c. Press the up/down key to display G. 4. Change the ground-enabled input ports (multiple ports can be set). Repeat a and b for the all ground-enabled input ports, then press the Enter key. a. Press the right/left arrow key to move the cursor on the input port number (01 to 08) that will be set to the ground-enabled input port. b. Press the up/down key to display -. Open the ground-enabled input ports to prevent the instrument from damage. Agilent B2200 User’s Guide, Edition 2 Front Panel Operation Operation To Use Couple Mode 1. Press the Couple Mode key to set the couple mode ON. Pressing the key again sets the mode OFF. 2. Perform the input couple port detection. a. Press the Menu key. The setup menu will be displayed on the LCD. b. Move the cursor to SCAN, then press the Enter key. The LCD displays NO. c. Press the arrow key to display YES, then press the Enter key. d. Press the Exit key. 3. Change the couple ports (multiple ports can be set). a. When the couple mode is ON, press the Port Function key. The blink-cursor appears on the first line of the LCD. b. Press the right/left arrow key to move the cursor on the input port number (01 to 14) that will be set to the input couple port. c. Press the up/down key to display C. d. Repeat b and c for the all couple ports, then press the Enter key. To Display Firmware Revision 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to CONFIG, then press the Enter key. 3. Move the cursor to REVISION, then press the Enter key. The firmware revision is displayed. To Display Module Information 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to CONFIG, then press the Enter key. 3. Move the cursor to UNIT, then press the Enter key. The module information is displayed. 4. Press the arrow keys to display another module information item. Agilent B2200 User’s Guide, Edition 2 Front Panel Operation Operation To Read Error Message 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to ERROR, then press the Enter key. 3. Move the cursor to DISPLAY, then press the Enter key to display the message. 4. Press the arrow keys to read another error message. A maximum of four error messages can be stored. To clear error buffer 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to ERROR, then press the Enter key. 3. Move the cursor to CLEAR, then press the Enter key. The LCD displays NO. 4. Press the arrow key to display YES, then press the Enter key to clear the error buffer, or press the Exit key to cancel operation. To Set Beeper 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to BEEP, then press the Enter key. 3. Press the arrow keys to select the beep ON or OFF. 4. Press the Enter key to make the setup effective, or press the Exit key to cancel changing the setup. To Set GPIB Address 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to CONFIG, then press the Enter key. 3. Move the cursor to ADDRESS, then press the Enter key. 4. Press the arrow keys to set the GPIB address. 5. Press the Enter key to make the setup effective, or press the Exit key to cancel changing the setup. To be effective the new address, reboot the Agilent B2200. Agilent B2200 User’s Guide, Edition 2 Front Panel Operation Operation To Set Remote Display Mode This instruction enables or disables the data display in the GPIB remote condition. See “RMT_DSPL” on page 3-33. LCD 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to RMT_DSPL, then press the Enter key. 3. Move the cursor to LCD, then press the Enter key. 4. Press the arrow keys to set the remote display mode ON or OFF. 5. Press the Enter key to make the setup effective, or press the Exit key to cancel changing the setup. LED matrix 1. Press the Menu key. The setup menu will be displayed on the LCD. 2. Move the cursor to RMT_DSPL, then press the Enter key. 3. Move the cursor to LED, then press the Enter key. 4. Press the arrow keys to set the remote display mode ON or OFF. 5. Press the Enter key to make the setup effective, or press the Exit key to cancel changing the setup. To Return to Local Mode Press the Local key. If the front panel keys are locked, send the :SYST:KLC command from an external computer, then press the Local key. Agilent B2200 User’s Guide, Edition 2 Front Panel Operation Switch Control Functions Switch Control Functions This section introduces the switch control functions of the Agilent B2200. • “Channel Configuration Mode” • “Connection Rule” • “Connection Sequence” •“Bias Mode” • “Ground Mode” • “Couple Mode” Agilent B2200 User’s Guide, Edition 2 Front Panel Operation Switch Control Functions Channel Configuration Mode The Agilent B2200 provides th...

Эта инструкция также подходит к моделям:
Компьютерные аксессуары - B2201A (1.34 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории