Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Aarrow Fires, модель Becton 7 mk3

Производитель: Aarrow Fires
Размер: 524.86 kb
Название файла: 9f20bd63-6e58-4ff6-9c80-96f0362ce28b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This will minimise the cantilever action. • Use gloves to provide additional grip. Becton Bunny & Becton 7 mk3 Gas stoves INTRODUCTION IMPORTANT NOTICES A qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current Building Regulations. Such person must be a registered CORGI engineer. This appliance is designed to run on natural gas only. Warning - Only use the appliance with the specified gas. The fire is fitted with a safety device to shut down the appliance if there is inadequate flue draw. If the fire shuts down for no apparent reason check chimney and air inlets to the room. In all cases the fire must not be re-lit until the safety aspects have been checked by a qualified gas engineer. Please note the following; • The safety device must never be put out of action. • Sealed components must not be interfered with. • Servicing instructions and part identification numbers are given towards the back of the manual. • Only use genuine Aarrow parts for replacements. • Ventilation, purpose built ventilation is not normally required for either appliance, normal adventitious room ventilation being sufficient. • Coal Set, see safety notice on page 4. All surfaces except the control knob, the control door handle and control door are considered to be working surfaces. Warning: Under no circumstances must the fire be operated if the glass is cracked or broken. Warning: If it is known or suspected that an operational or ignition fault exists on the appliance, it must not be used until it has been investigated and corrected by a qualified gas engineer. Warning: THIS GAS APPLIANCE MUST BE SERVICED EVERY TWELVE MONTHS BY A QUALIFIED GAS ENGINEER. STATUTORY REQUIREMENTS The current Gas Safety (Installation and Use) Regulations (as amended). The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations. Detailed recommendations are outlined in the current issue of the following British Standards:BS5440 parts 1 and 2, BS5871 part 1 and BS6891. Any Manufacturer's Instructions must not be taken as overriding statutory requirements. CERTIFICATION This appliance is CE certificated for performance and safety. Therefore, it is important that no alteration is made to the appliance. Any alteration not approved by Aarrow Fires Ltd. will invalidate the guarantee. Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS Category I2H For use in GB and IE at a supply pressure of 20mbar TECHNICAL DATA Becton Bunny Natural Gas Becton 7 Natural Gas Main Burner Aeromatic AC13/112511 (mod 334) Aeromatic AC13/112511 (mod 334) Injector Bray 82-700 Bray 82-700 Max. Heat Setting Heat Input (net) 3.7 kW 5.0 kW Gas Rate Cold Setting Pressure 0.391m3/hour 1.5mb 0.529m3/hour 3.5mb Min. Heat Setting Heat Input (net) 2.4 kW 3.3 kW Gas Rate 0.254 m3/hour 0.349 m3/hour NOx CLASS CLASS 4 CLASS 4 FIRE DIMENSIONS Fig. 2 Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS FITTING THE LINING PANELS Becton 7 only. The lining panels supplied are to be installed into the fire before the coal matrix is fitted. Note: The lining panels are reversible (brick or plain pattern) Ensure the appliance is cold. With the fire door open, the glass retaining frame and the coal set removed, proceed as follows: Do not force the linnings into position. 1. Position the rear lining face down at the rear of the fire. Ensure the cutout faces the rear of the fire. Fig. 3a Positioning the rear lining 2. Locate side lining in the right hand side of the fire. First position the tall edge into the radius at the front of the fire.(See Fig.3b below) Fig. 3b Fitting the R/H side lining 3. Then rotate the rear edge until the top faces match up the angle faces at the rear of the fire. (See Fig. 3c) Repeat exercise for the left hand side. Fig. 3c Fitting the side linings 4. Rotate the rear lining to bring it vertical (Fig. 3d) Fig. 3d Rotating the rear lining 5. Centre the assembly. Line up each end of the rear lining with the edges of the fixed matrix plate. (See Fig. 3e) Fig. 3e Liner panels assembled in the fire. Once the lining panels are fitted, arrange the coals. See “Arranging the coals” on page 8. Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS ARRANGING THE COALS Safety Notice - Please see SAFETY NOTICES ref. Coal set page 4. Warning: The coals and the coal matrices are fragile ensure they are handled carefully. Ensure location is correct. Do not force the matrix into position. If the coals and/or the coal matrices are damaged they must be replaced with genuine Aarrow replacement sets. Warning: An incorrect coal layout may cause soot to build up inside the fire and therefore invalidate the guarantee. Ensure the appliance is cold. Step 1 Place the base matrix on the matrix plate centrally between the end tabs of the location bar. (Fig 4a) Fig 4a Step 2...

Эта инструкция также подходит к моделям:
Камины - Becton 7 mk3 (524.86 kb)
Камины - Becton 7 mk3 (524.86 kb)
Камины - Becton 7 mk3 (524.86 kb)
Камины - Becton Bunny (524.86 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории