Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Enviro, модель EG 28

Производитель: Enviro
Размер: 845.04 kb
Название файла: eg28directventmanual.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


UPON CONNECTION, MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL. Manifold Pressure Tap. Inlet Pressure Tap. Millivolt Terminals Pilot Adjustment screw. "HI-LOW" Burner Gas Knob. Pilot "ON-OFF" Gas Knob. Text Box: ORIFICE SIZES, PRESSURE AND BTU’S The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kPa) or damage will occur to the valve. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). When using copper or flex connectors use only fittings approved for gas connections. TO TEST The pressure taps are located in the top right corner on the valve face (right - inlet, left - manifold pressure). • Turn setscrew counter clockwise to loosen, 2 turns. • Place 5/16" hose over pressure tap system. • When finished, release pressure, remove hose & tighten setscrew. Always check for gas leaks with a soap and water solution after completing the required pressure test. NEVER USE AN OPEN FLAME FOR LEAK TESTING ELECTRICAL The ENVIROGAS EG 28.FS.DV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA. NOTE: • Operation of the fan increases the efficiency and the heat output of the appliance. • The thermostat connects to the two purple wires in the harness • Control panel light uses a 7w max. bulb • If the unit is installed in a Mobile Home it must be connected to a grounding rod. • If the unit is installed in a Mobile Home it must be bolted securely to the floor. WARNING: ELECTRICAL GROUNDING INSTRUCTIONS. This appliance is equipped with a three- prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three-prong receptacle. DO NOT cut or remove the grounding prong from the plug. INSTALLING REMOTE THERMOSTAT OR WALL SWITCH RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire) 1. Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch. 2. Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH). RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE) WHEN USING WALL THERMOSTAT WIRE SIZE MAXIMUM LENGTH 14 GAUGE 100 FEET 16 GAUGE 64 FEET 18 GAUGE 40 FEET 20 GAUGE 18 FEET Text Box: CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 220° Orifice Blank Convection Blower Light Bulb Holder Light Switch (momentary) Fan Controller Log Set (with Embers) Thermocouple Embers Thermopile Door Gasket Convection Fan Sensor 120° (48°C) Accessories Gold trim Package Low Voltage Thermostat INSTALLING OR REMOVING THE BLOWER The blower does not require lubrication. 1. Turn the unit off and remove the log set. 2. Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift the tray out. 3. Remove the 4-5/16” bolts that hold the blower mounting plate to the back firewall. Use a light lubricating oil on screws before removal. 4. Carefully pull the assembly into the firebox. Install the blower onto the mounting bracket (blower outlets pointing through the two holes in the bracket) using the 4 screws provided. 5. Connect wires according to the wiring diagram. (If removing the blower, disconnect the blower leads from the harness. Remove the blower.) 6. Check mounting plate gasket and reverse steps 1 through 4. ADJUSTING THE VENTURI • Remove the ash shelf by undoing the screw at each end, pull shelf towards you. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting. • The burner flame should be a bright yellow/orange when hot. Excessive blue is to lean and dark orange with soot is too rich. FUEL CONVERSION “Warning” This conve...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории