WARNING: This appliance, when installed must be electrically grounded in accordance with local code or in the absence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1. Figure 32 - Relocating Junction Box Receptacle and Electrical Supply Connection A pre-wired junction box receptacle with strain relief is provided on the right side of the cabinet for hard wiring the unit to a 15 Amp, 120VAC, 60Hz grounded branch circuit. If the installation demands that the electrical supply be connected from the left side, the entire receptacle box can be relocated to the left side by following these instructions: Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only: 1. Remove the 2 screws and outer cover with strain relief bushing on the right side of the cabinet (see Figure 32). 2. Remove inner retaining screw on the junction box mounting tab. 3. Slide the junction box up until the screw mounting tab is lined up to the notch in the outer cabinet. 4. Swing the junction box out and slip the retaining flange out through the slot in the outer cabinet. 5. Remove the two screws and outer cover on the left side of the outer cabinet. 6. Reinsert the junction box retaining flange through the slot now on the left side and swing the screw mounting tab back through the notch as before. 7. Slide the junction box down till the mounting tab holes line up and replace the inner retaining screw. 8. With the junction box cover removed, pull the end of 3-wire Romex supply line through the universal strain relief bushing on the cover. (see Figure 32). 9. Strip back the outer Romex to about 4” and connect the black, white and green wires accordingly using 3 wire nut connectors. 10. Tuck the tailing wires into the junction box and replace the junction box cover using the 2 remaining screws. 11. Tighten down the strain adjustment on the universal bushing until the Romex sheathing is secured. The electrical connection is now complete. OPTIONAL BLOWER INSTALLATION NOTICE: If installing the blower in an existing fireplace with gas connections, shut off the gas supply to the fireplace before attempting to service this appliance. If it is necessary to disconnect the gas supply, contact a qualified service person to do this. Model BK Installation Follow all instructions provided in the blower accessory kit: 1. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 33). 2. Attach green ground wire from power cord to blower housing using screw provided (see Figure 33). Tighten screws securely 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 33). Magnetic StripsExhaustPortScrewGreenGround WireSpade TerminalsSide ViewLower FireboxCavityBlowerLocation Figure 33 - Blower Model BK OPTIONAL BLOWER INSTALLATION (Cont.) Models BK and BKT OPTIONAL BLOWER INSTALLATION Continued Speed ControlControlShaftLocknutControl KnobBlower Plug-inDuplex OutletIgnition Module Bracket Wiring Diagram Decal6" in Front of Blower 4. Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight. 5. Mount speed control box by placing the plastic control shaft through the opening in switch bracket (see Figure 34) or the igniton module bracket (see Figure 35). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft. 7. Turn on power to dulex outlet if previously turned off per the warning in column 1, page 17. 8. Plug in blower power cord. a. If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox. b. If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to Electrical Supply Connection, page 17 for instructions on wiring the duplex box. 9. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing. 10. Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 6” in front of the blower (see Figure 36). Figure 35 - Attaching Speed Control to Fireplace (Electronic Models (VCD36RE and VCD36TE) Figure 36 - Locating Wiring Diagram D...

Эта инструкция также подходит к моделям:
Камины - (V) CD36R(N (6.22 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории