Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Desa, модель (V)G36HR

Производитель: Desa
Размер: 1.28 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Tighten screws. See Figure 23. Spring Clip Figure 23 - Adjusting Bi-Fold Doors 116010-01E operaTion and MainTenance guidelines GLASS DOORS Glass doors are optional with this fireplace. When fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 24). A fireplace equipped with glass doors operates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open. The following tips should be followed to assure that both fireplace and glass door retain their beauty and function properly. Both flue damper and glass doors must be fully opened before starting fire. This will provide sufficient combustion air and maintain safe temperatures in firebox. IMPORTANT: The glass must be allowed to warm slowly and evenly. Tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep fire away from doors and never allow flames to contact glass. WARNING: Fireplaces equipped with glass doors should be operated only with doorsfullyopenedordoorsfully closed.Doors,ifleft partlyopen, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke. Doors Fully Closed Fireplace Front Fireplace Front Doors Fully Opened Figure 24 - Bi-Fold Glass Doors Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or vent- free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 dated August, 1993. If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters,ANSI Z21.11.2 are to be installed in this fireplace. OUTSIDE AIR AND DAMPER HANDLE OPERATION Damper handle, which opens and closes damper blade, is located in the upper front face of fireplace. Pushing handle forward and up through keyway slot will free damper blade to automatically open. Pushing handle forward and down will lock damper blade closed (see Figure 25, page 14). The outside air kit lever is located at left and right hand sides of fireplace (see Figure 26, page 14). Lifting lever up will free outside air door to open. Pulling lever down will lock the door. WARNING: Risk of fire! Replace grate with DESA Heating, LLCmodel109496-03grateonly. This grate has been designed to keep the operation of your fireplace safe and efficient. 116010-01E operaTion and MainTenance guidelines Continued Damper Weight Open Position Damper Weight To Close Damper To Open Damper Closed Position Figure 26 - Outside Air Kit Lever Figure 25 - Operating Damper Handle replaceMenT parTs HERRINGBONE BRICK LINER Bottom Front Brick Refractory 116092-01 - VG36H Models 116092-02 - G36H Models Bottom Rear Brick Refractory 116089-01 - VG36H Models 116089-02 - G36H Models Right Brick Refractory 116087-01 - VG36H Models 116087-02 - G36H Models Left Brick Refractory 116086-01 - VG36H Models 116086-02 - G36H Models Rear Brick Refractory 116088-01 - VG36H Models 116088-02 - G36H Models STANDARD BRICK LINER Bottom Front Brick Refractory 116091-01 - VG36 Models 116091-02 - G36 Models Bottom Rear Brick Refractory 116084-01 - VG36 Models 116084-02 - G36 Models Right Brick Refractory 116082-01 - VG36 Models 116082-02 - G36 Models Left Brick Refractory 116081-01 - VG36 Models 116081-02 - G36 Models Rear Brick Refractory 116083-01 - VG36 Models 116083-02 - G36 Models 116010-01E replaceMenT parTs Continued GRATE 109496-03 - Model GM36 Series EMBER PROTECTOR - EP36 ASH BOx - 111498-01 Technical serVice You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating, LLC at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA Heating, LLC’s web site at accessories BI-FOLD GLASS DOOR OPTIONAL OUTSIDE AIR KIT FOR BDG36 - 36" Black Finish FLOOR INSTALLATION - AK4F BDG36B - 36" Brushed Brass Finish BDG36P - 36" Platinum Finish BDG36PB - 36" Polished Brass Finish OPTIONAL OUTSIDE AIR KIT FORSIDEWALL INSTALLATION - AK-4 PN 01576 STORM COLLAR - SC1-1 DOUBLE...

Эта инструкция также подходит к моделям:
Камины - (V)G36 (1.28 mb)
Камины - (V)G36H (1.28 mb)
Камины - (V)G36R (1.28 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории