C 43" (1092 mm) Min. *Note: Framing dimensions calculated for ..." drywall finish. 40" (1016 mm) Front View (CFPF) Top View Energy Wall Wall Gas Line 2 x 4 Outside ..." (16 mm) 3 ..." (79 mm) Drywall Drywall * Bracket Bracket Framing Top View * ..." (13mm) Required Air Space Clearance Figure 8 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Step 2. Route a ..." (13 mm) gas line along the left or right side framing (Figure 9). Step 2. Route a ..." (13 mm) gas line along the left or right side framing (Figure 9). 3 ..." (98 mm) 4" (102 mm) ...” Gas Line Stud Plate Standard Left Side 11 ..." (289 mm) 4 ..." (105 mm) ...” Gas Line Stud Plate OptionalRight Side (ST) Figure 9 Step 3. Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each. Align with the three holes on each side of the appliance (refer to Figure 5). Install the hood on all units. Position the hood in the open area above the appliance door. Insert the tabs, on each end of the hood, into the bracket at each end. Bend the two tabs over to secure. Step 4. Position appliance into prepared framing, secure with 6d nails at the nailing flange along each side. Step 5. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 10illustrates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes. Gas Flex Line Kit, Model GFLV .." NPT x .." .." x .." Flare Flare FittingShut-Off Valve To Appliance .." Flex Tubing Gas Valve .." Union Gas Stub .." Close Nipple .." Shut-Off Valve A. Mix a 50% dish soap, 50% water solution. B. Light the appliance (refer to safety and lighting instructions on page 15). C. Brush all joints and connections with the soapy water solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” position. Either tighten or refasten the leaking connec- tion and retest as described above. D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and pro- ducing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports. An external regulator must be used on all pro- pane (L.P.G.) heaters, in addition to the regula- tor fitted to the heater, to reduce the supply tank pressure to 13" w.c. (maximum). WARNING: CONNECTING DIRECTLY TO AN UNREGULATED PROPANE TANK CAN CAUSE AN EXPLOSION. Step 6. Wiring – The wiring diagram is de- tailed in Figure 12. Refer to Figure 13 to field wire optional wall switch. All electrical wiring must be in accordance with local codes or, in the absence of local codes the latest edition of the National Electrical Code, ANSI/NFPA 70. The heater must be electrically grounded. .." x .." Reducer Figure 10 Control Valve Lower Control Compartment Door Figure 11 The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door (Figure 11). The control valve has a ..." NPT thread inlet port and is fitted with two elbows and a nipple to provide the necessary offset. Plan your connections accordingly. Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12. Select a convenient location for the remote wall switch and connect the wiring to the appliance (Figure 13). CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH TO A 120V POWER SUPPLY. Note:The optional rocker switch is mounted to the appliance and wired in the same way as the remote wall switch. Figure 12 Figure 13 Note:Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet. Standard Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. *For Optional Wall and/or On/Off Switch Attachment TH TH & TP THERMOCOUPLE RED RED DOOR SW WHT THERMOPILE BLK TP BLKGAS CONTROL VALVE * Optional Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. Factory Wired Field Wired TH TH & TP THERMOCOUPLE RED RED DOOR SW WHT THERMOPILE BLK TP BLK OPTIONAL WALL AND/OR ON/OFFROCKER SWITCH GAS CONTROL VALVE NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Step 7. Installing the Optional Remote Wall Switch – The standard millivolt sy...
Эта инструкция также подходит к моделям:Камины - CFPF-CMN (585.54 kb)
Камины - CFPF-CMP (585.54 kb)
Камины - CFST-CMP (585.54 kb)