The supplied cord assembly may also be routed out onto the hearth to a nearby outlet. WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout. • Refer to Figure 10.2, IPI Wiring Diagram. • This appliance is equipped with an IntelliFire Plus™ control valve which operates on a 6 volt/1.5 AMP system. • Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use. ON/OFF Switch • An ON/OFF switch is included with the appliance surround and should be attached to surround/facing. (See Installation instructions for remote control/fronts). • If desired an additional wall switch or thermostat may be added to system. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11 27 Figure 10.2 IPI Wiring Diagram BLK RED BATTERY PACK 6V DC GROUND BROWN GREEN (MAIN) ROCKER SWITCH ORANGE (PILOT) WALL SWITCH OR REMOTE INSTALL TO CORD ASSEMBLY 120VAC INTERMITTENT PILOT IGNITOR RC100 RC200 RC300 (OPTIONAL WALL CONTROLS) TO CORD ASSEMBLY (110V) WHT ORG MODULE FLAME MODULATION AUX1 AUX2 AUX300 MODULE FAN BLK RED AUX2 NOT USED FOR INSERT MODELS. PROTECTIVE COVER INCLUDED Figure 10.3 Standing Pilot Ignition Wiring Diagram PILOT ASSEMBLY PIEZO VALVE ROCKER SWITCH RED WHT THERMOCOUPLE THERMOPILE OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE 28 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11 Figure 10.4 Fan Wiring Diagram BLOWERS BLOWER RECEPTACLE BLK GRN BLK BLK GRN WHT BLK GRN BLK BLK GRN BLK WHT BLK BLK BLK PLUG INTO 120V EXISTING OUTLET TEMPERATURE SENSOR SWITCH VARIABLE SPEED CONTROL DC REGULATOR RECEPTACLE PLUG 120V EXISTING OUTLET BROWN RED BLACK TO VALVE TO VALVE BRACKET (GROUND) ORANGE GREEN BLOWER SPEED CONTROL (RHEOSTAT) TEMPERATURE SENSOR SWITCH D. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control. • To connect optional accessories, the supplied cord assembly should be used. See attached Figure 10.4 for a wiring diagram for a blower or remote. Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. • Plug the cord into a convenient outlet. • Must use cord supplied. • An IntelliFire Plus™ Wireless Controls or WSK-21 wired wall switch may be used with the IntelliFire Plus™ Ignition System. Hearth & Home Technologies recommends that IntelliFire Plus™ wireless controls be used for their features and functionality with the IntelliFire Plus™ ignition system. • A standard ON/OFF switch is compatible. WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES). NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE. Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11 29 Figure 10.5 Wiring Diagram - Fan with RC200/RC300 Remote PLUG 120V EXISTING OUTLET GRN (2) BLK (2) BLK (2) GRN (2) BLK (2) STEPS 3 & 4 WHT (2) BLOWER SPEED CONTROL (RHEOSTAT) SENSOR SWITCH STEPS 1 & 2 STEP 5 BLOWERS BLOWER RECEPTICLE BLK GRN BLK BLK GRN WHT BLK GRN BLK BLK GRN WHT BLK BLK PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTICLE AUX 300 MODULE TO CONTROL FAN MODULE E. Fan Wiring with Remote This appliance may be used with an RC200 or RC300 remote control. See Figure 10.5. 1. Remove cord assembly spades from rheostat and sensor switch. NOTICE: Fan speed and operation are controlled by the remote control. The sensor switch and rheostat are no longer needed. 2. Plug two cord assembly spade connectors together. 3. Unplug fan cord assembly from standard cord assembly. 4. Plug fan cord assembly into AUX300 module. 5. Plug AUX300 module into the standard cord assembly. NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES). NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE. F. Control Module Operation See Section 2.H for control module operation instructions. NOTE: SENSOR SWITCH AND RHEOSTAT SPEED CONTROL MUST BE REMOVED FROM CIRCUIT IF SYSTEM IS CONTROLLED WITH RC200/RC300 REMOTE. 30 Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11 11 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum...
Эта инструкция также подходит к моделям:Камины - GRAND-I35 (2.96 mb)
Камины - SUPREME-I30 (2.96 mb)
Камины - SUPREME-I30-SP (2.96 mb)