Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Heat & Glo LifeStyle, модель EM-485TH

Производитель: Heat & Glo LifeStyle
Размер: 4.35 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Flange Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST375 Square Termination Cap • TR344 Round Termination Cap • ST375 Square Termination Cap • TR342 Round Telescoping Termination Cap 35 Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08 Chimney Pipe Chase Top Termination Cap Chase 3 in. (76 mm) Maximum top of chase to top of chimney section Collar 2 in. (51 mm) Minimum Height Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm). Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks. Figure 9.7 Installing a TS345/TS345P Square Termination Cap • TS345/TS345P Square Termination Cap Chimney Pipe Chase Top Termination Cap Chase Collar 2 in. (51 mm) Minimum Height Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks. The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase 2 in. (51 mm) 7 in. (178 mm) Figure 9.8 Installing a TCT375 Terra Cotta Cap • TCT375 Terra Cotta Cap • European Copper Series Termination Cap brass screw (8) (9 for the King-Style) bolt (8)* Cap Top Cap Base (Be sure holes in cap top and cap base are aligned.) Cap top comes assembled in place. bracket (8)* washer (8)* nut (8)* CT-3A Adapter 2 in. (51 mm) typical collar height chase top (metal or masonry) screw (8)* SL pipe 14-1/2 in. (368 mm) Figure 9.9 Installing an Adapter for European Copper Cap Series (CT-King shown) 110 Shrouds A. Radiation Shield O 17 1/2 in. (444.5 mm) Round Hole to fit over cap • Some shrouds require a radiation shield. Use where specified. B. Field Constructed Shrouds WARNING! Risk of Fire! Shrouds must be constructed as specified. Improper construction may overheat chase top. • Chase top shrouds may be field constructed where permitted by regional building codes. NOTICE: Some regional codes require an agency-Listed shroud. Consult your local building officials. • Hearth & Home Technologies Inc. supplies UL listed shrouds. See your dealer for details. • Shrouds must be constructed of minimum 26 ga sheet metal. • Different shroud designs have been tested for Hearth Technologies fireplace systems using the TR11 and TR11T termination caps. • The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel. • The wire mesh is optional but recommended and must be .018 in. thick minimum. Open Top Shroud (TR342 & TR11/TR11T caps require radiation shield) 3 in. (76 mm) tall legs Length x Width to fit inside shroud Figure 10.1 Radiation Shield 36 3 in (76 mm) minimum Min. Base Dim. Min. Base Dim. Min. Top Dim. Min. Top Dim. Min. Opening Width Min. Opening Width Figure 10.2 Open Top Shroud Dimensions Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08 26 x 26 660 x 660 23 x 23 584 x 584 20 x 20 508 x 508 TS345 TR342 TR342/344TV Min. Base Dims. in 23 x 23 28 x 28 mm 584 x 584 711 x 711 Radiation Shield Required Min. Top Dims. in 20 x 20 25 x 25 mm 508 x 508 635 x 635 Min. Opening Width in 17 x 17 22 x 22 mm 432 x 432 559 x 559 Mailbox Style Shroud (radiation shield required) 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions 28 x 30 711 x 762 Min. Height Above Radiation Shield 20-1/2 521 22 x 24 559 x 610 TS345 TR342 TR342/344TV Min. Base Dims. in N/A 26-1/2 x 28 mm N/A 673 x 711 in N/A 21-1/4 mm N/A 540 Min. Opening Width in N/A 20-1/2 x 22 mm N/A 521 x 559 Roofed Style Shroud (radiation shield required) Minimum Opening Height Minimum Base Dimension Min. Opening WidthMin. Base Dimension Minimum Height above Radiation Shield Chase Top Radiation Shield 3 in. (76 mm) Radiation Shield Height Termination Cap Figure 10.4 Roofed Style Shroud Dimensions 27 x 27 686 x 686 Min. Height Above Radiation Shield 16 406 21 533 12 305 TS345/445 TR342/344 TR442/444 TR342/344TV Min. Base Dims. in N/A 27 x 27 mm N/A 686 x 686 in N/A 16 mm N/A 406 Min. Opening Width in N/A 21 mm N/A 533 Min. Opening Height in N/A 12 mm N/A 305 Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08 38 C D A C 11 Finishing A. Non-Combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - Tile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C B. Combustible Materials • Materials made of or surfaced with any of the following materials: - Wood - Compressed paper - Plant fi bers - Plastic • Any material that can ignite and burn; fl ame proofed or not, plastered or un-plastered Figure 11.1 Hearth Extension Dimensions Table 11.2 C. Hearth Extension WARNING! Risk of fi re! High temperatur...

Эта инструкция также подходит к моделям:
Камины - EM-415 (4.35 mb)
Камины - EM-415H (4.35 mb)
Камины - EM-485T (4.35 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории