See Figure 1 for location suggestions. CAUTION Do not install in the vicinity where gasoline or other fl ammable liquids may be stored. The Vent-Free firebox must be kept clear and free from these combustible materials. WARNING Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fi replace. WARNING Do not install these built-in Vent- Free fireboxes in sleeping quarters, or in recreational vehicles. WARNINGS Do not install these appliances: • Where curtains, furniture, clothing or other fl ammable objects are less than 42" from the front of the Vent-Free room heater. • In high traffi c areas. • In windy or drafty areas. Not to Scale Figure 1 Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained. Left and right clearances are determined when facing the front of the fi rebox. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fi re hazard. Sidewall clearances: The sides of the fi rebox opening must be at least 16" from any combustible wall (Figure 2 ). 40" 16" OptionalHearth Extension Figure 2 Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2 ). Noncombustible material: Noncombustible materials, such as slate and marble, must be at least 1/2" thick and may be used without restriction above the firebox opening, to the sides or as a hearth extension, so long as they do not obstruct vent openings for heat circulating models. RECOMMENDATION: Use high temperature finish material for the mantels and/or use the canopy (for UVFRC-3628, UVFRC-3628H, UVFRC-4228 & UVFRC-4228-H). Combustible Wall Clearance Above Appliance (all models) Finished Wall FireplaceOpening Top Stand- Off Spacer (on appliance) Top of Appliance Header Shown with Canopy Installed (required on UVF-36 only) Non-Combustible Material 3" Min. (shaded area) Figure 3 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Figure 5 Combustible Mantel and Trim Clearance Model UVF-36 WITH Canopy Installed Canopy is required on all installations for this model only. EXAMPLE: If you choose to install a mantel that projects 5", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). EXAMPLE: If you choose to install a mantel that projects 4", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). Models UVFRC-3628 and UVFRC-4228 WITH Canopy Installed Canopy is optional on these models 16” 9-1/2” 2”3”4”5”6” 10” 11” 12” 13” 14” 15” Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Header Top Spaceron Appliance Safe Zone Canopy Non-Combustible Material 3” Min. Example Example Coordinate in ()Example Combustible Material (wall) Figure 4 16” 17” 18” 9” 3”4”...

Эта инструкция также подходит к моделям:
Вентиляторы - UVFRC-3628 (1.06 mb)
Вентиляторы - UVFRC-3628 (1.06 mb)
Камины - UVFRC-3628-H (1.06 mb)
Камины - UVF-36 (1.06 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории