|
Фрагмент инструкции
When first lighting the pilot light, it will take a few minutes to purge the trapped air. Once purging is complete, the pilot and burner will light and will operate as outlined in the instruction manual. Subsequent lighting of the appliance will not require purging. When lit for the first time, the appliance will emit a slight odour for an hour or two. This is due to the paint and lubricants used in the manufacturing process. Flame Adjustment For units equipped with Hi/Lo valves, flame adjustment is achieved by rotating the Hi/Lo adjustment knob located near the centre of the gas control valve. Figure 12 – SIT 820 Gas Control Knob Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames (refer Figures 13 & 14). The burner flame is checked after 5 minutes operation. It should be mainly a yellow flame with possibly some blue flame at the base. The yellow flame should not be producing soot deposits (insufficient air). The flame should not be excessively blue and noisy (excess air). Figure 13 Figure 14 If any of the flames appear abnormal call a Rheem service or your licensed service technician. Troubleshooting Nova SIT 820 Standing Pilot START CHECK Gas Supply On Gas Supply On Yes Yes Pilot Stays Lit Yes Pilot Lights Main Burner Yes System OK No No No No Gas supply connected Shut off valve open Lockout has engaged. Wait 60 seconds and try again. Piezo not tight enough for good ground. For spark at electrode while depressing Piezo 1/8” gap to pilot hood required. All wiring connections. Replace Piezo ignitor. Thermodisk. Air in gas pipe. Thermopile requires a min of 325Mv. Adjust pilot flame height. All wiring connections. Replace thermopile. Thermocouple needs a min of 14mV Defective valve. Turn to pilot, meter should read greater than 100Mv. Thermodisk. Faulty gas valve. Thermopile requires min of 325mV Watch for grounded wires. Blocked burner injector. Maintenance Burner and burner compartment It is important to keep the burner and the burner compartment clean. At least once a year the logs should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace is in use. Cleaning the Standing Pilot Control System The burner and control system consists of: • Main burner • Gas orifice • Pilot burner • Thermopile • Combination millivolt gas valve Most of these components may require only an occasional check-up and cleaning and some may require adjustment. If repair is necessary, it should be performed a qualified and suitably licensed service technician. In order to properly clean the burner and pilot assembly, turn off the gas to the unit, remove all logs exposing the burner and pilot assembly. Clean all foreign materials from the top of the burner. Check to make sure that burner parts are clean. Visually inspect pilot. Brush or blow away any dust or lint accumulation. If the pilot injector is blocked, disassembly by a qualified service technician may be required to remove the foreign matter. To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady not lifting or floating. Typically the top 1 to 1.5cm of the thermopile should be engulfed in the pilot flame. To adjust the pilot burner, turn pilot screw marked “pilot” for the proper flame size. The aeration shutter is set at the factory and no adjustment should be necessary. Parts List Part 6: Warranty LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner or steel tube burner. BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXTENDED LIFETIME WARRANTY The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta- Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document COMPONENT WARRANTY CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to ...
Эта инструкция также подходит к моделям:Камины - ODGSR36APAU (457.37 kb)