Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Hearth and Home Technologies, модель 6000G-IPI

Производитель: Hearth and Home Technologies
Размер: 3.54 mb
Название файла: a5eacd46-44c8-42b9-b019-5c354d24bc01.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps. Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner. Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infi ltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness. To further prevent drafts, the wall shield and ceiling fire- stops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced insulation. If the appliance is being installed on a cement surface, a layer of plywood may be placed underneath to prevent conducting cold up into the room. C. Clearances NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood. WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe: • Insulation and other materials must be secured to prevent accidental contact. • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. GIHEFJC B D A *MINIMUM FRAMING DIMENSIONS A B C** D E F G H I J Rough Opening (Vent Pipe) Rough Opening (Height) Rough Opening (Depth) Rough Opening (Width) Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Appliance Front of Appliance Inches 10 38-1/2 22 42 26-5/8 0 0 1/2 1/2 36 Millimeters 254 978 559 1067 676 0 0 13 13 915 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90. elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. O • 12/08 D. Mantel and Wall Projections Combustible Mantel Legs or Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc). Combustible Mantels MEASUREMENTS FROM TOP EDGE OF THE OPENING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 TO CEILING 9 10 11 12 8 7 6 5 4 3 25 18 Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fireplace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles ABINTERIOR WALL TOP VIEW MANTEL LEG OR WALL PROJECTIONS FIREPLACE OPENING If A minimum is ____, then B maximum is_____. A Inches 2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Millimeters 62 87 113 138 164 189 B Inches 1 2 3 4 5 . Millimeters 25 51 76 102 127 . Figure 5.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. O • 12/08 6 66 Termination Locations A. Vent Termination Minimum Clearances WARNING Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fire. HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X/ 12 LOWEST DISCHARGE OPENING 2 FT. MIN. 20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Gas, Wood or Fuel Oil Termination Cap B Gas Termination Cap ** A* * If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover. ** In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. A B 6in. (minimum)upto20in. 152mm/508mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum Figure 6.2 Staggered Termination Caps Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12.................................................1.25* Over 7/12 to 8/12.................................................1.5* Over 8/12 to 9/12.................................................2.0* Over 9/12 to 10/12...............................................2.5 Over 10/12 to 11/12.............................................3.25 Over 11/12 to 12/12.............................................4.0 Over 12/12 to 14/12......................

Эта инструкция также подходит к моделям:
Камины - 6000G (3.54 mb)
Камины - 6000G-IPILP (3.54 mb)
Камины - 6000G-LP (3.54 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории