Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Hearth and Home Technologies, модель 6000GL-IPILP-S

Производитель: Hearth and Home Technologies
Размер: 3.33 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The small indentation on one side goes down. Lean the refractory slightly so it doesn’t tip over. Figure 14.2 STEP 2. Place the left side refractory onto the left side of the burner. Push the back refractory against the back wall. Place the bumps on the bottom of the left refractory into the grooves on the burner surface. Push to top gently against the side of the fireplace. Once in place push it back so the bevel cuts sit against each other and the seam is minimized. Figure 14.3 STEP 3. Repeat step 2 for the right side. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 53 F. Ember Placement WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation. Ember material is shipped with this gas appliance. To place the ember material: • Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front). • Place dime-size pieces of Glowing Embers® just in front of the port trail, but not on or in between the ports (see Figure 14.4). Care should be taken so that the ports are not covered. Failure to follow this procedure will likely cause lighting and sooting problems. Figure 14.4 Placement of Embers EMBER MATERIAL • Place Mystic Embers on areas of base refractory away from port holes. Use this material to give the appliance a realistic ash bed. • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. G. Install the Log Assembly Log Assembly: LOGS-6000GL If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions. STEP 2. Place the metal grate on top of the burner. Position the legs of the grate into the forward set of indentations in the burner top. The grate should not cover any ports in the burner. STEP 1. CAUTION: Logs are fragile! Carefully remove the logs, grate and supporting cardboard from the inside of the fireplace See Figure 14.5. Figure 14.5 11 11 22 33 44 55 66 11 HUMPHUMP Figure 14.6 Front View Figure 14.7 Top View STEP 3. Log #1 (SRV2102-010): Log #1 is the back burning log. The air shutter in the end of the burner tube goes over the brass orifice located behind the main burner. The log should be parallel to back refractory. 22 22 Figure 14.8 Front View Figure 14.9 Top View STEP 4. Log #2 (SRV2102-101): Place log #2 on top of log #1. The bottom side of this log has a slot in it that goes over the left metal tab sticking up out of the top of log #1. The left end of this log sits on the burner surface. 2102-910 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 33 33 33 Figure 14.10 Front View Figure 14.11 Top View STEP 5. Log #3 (SRV2102-105): Place log #3 on top of the burner surface in front of the hump. The bottom of the log is contoured to match some of the burner surface features. Slide it back against the hump. The “V” shaped notch in the front bottom of the log rests into the second from the left grate tine. 44 44 Figure 14.12 Front View Figure 14.13 Top View STEP 6. Log #4 (SRV2102-104): Place log #4 on top of the burner. There is a groove in the bottom of this log. Place this groove over the second tine from the right on the grate and slide the log forward. A group of ports should be visible through the hole in the log. 55 55 Figure 14.14 Front View Figure 14.15 Top View STEP 7. Log #5 (SRV2102-103): Place log #5 on top of log #1 and log #3. The bottom of this log has a slot in it that goes over the metal tab molded in the top right side of log #1. The thin end of the log rests in the flat spot molded into the top of log #3. Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 56 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 K. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed service technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.19. • Loosen the wing nut. • Push the air handle in to close the air shutter. • Pull the air handle out to open the air shutter. • Tighten the wing nut. NOTICE: If sooting occurs, provide more air by opening the air shutter. Figure 14.19 Air Shutter Figure 14.18 Fixed Glass Assembly H. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam or scratch glass. • DO NOT operate fi replace with glass removed, cracked, broken or scratched. • Replace as a complete assembly. Removing Fixed Glass Assembly • Pull the four glass assembly latches out of the...

Эта инструкция также подходит к моделям:
Камины - 6000GL-IPI-R (3.33 mb)
Камины - 6000GL-IPI-S (3.33 mb)
Камины - 6000GL-IPILP-R (3.33 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории