vinyl soffi t and overhang P = 8 ft. QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2/3 x Q ACTUAL 4 caps 12 feet 1/2 x Q ACTUAL QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL Covered Alcove Applications (See Note 1) (See Note 5) (See Note 5) J** = 7 ft. ......................... clearance above paved sidewalk or a paved driveway located on public property K = 6 inches................. clearance from sides of electrical service L = 12 inches................ clearance above electrical service Measure horizontal clearances from this surface. Measure vertical clearances from this surface. (See Note 2) (See Note 2) 7 77 Vent Information and Diagrams A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fittings or joining methods from different manufacturers. The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. B. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description V1 First section (closest to appliance) of vertical length V2 Second section of vertical length H1 First section (closest to appliance) of horizontal length H2 Subsequent sections of horizontal length C. Use of Elbows Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 7.1). Two 45. elbows may be used in place of one 90. elbow. On 45. runs, one foot of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A length of straight pipe is allowed between two 45. elbows (see Figure 7.1). Figure 7.1 Horizontal Vertical 8-1/2 in. 8- 1/2 in. 12in. D. Measuring Standards Vertical and horizontal measurements listed in the vent diagrams were made using the following standards. • Pipe measurements are shown using the effective length of pipe (see Figure 7.2). • Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 6.4). • Vertical terminations are measured to bottom of termination cap. • Horizontal pipe installed level with no rise. Figure 7.2 DVP Pipe Effective Length EffectiveHeight/LengthPipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 24 Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 V1 Minimum H1 + H2 Maximum 1 ft. 305 mm Cannot do 1 1/2 ft. 457 mm 1-1/2 ft. 457 mm 2 ft. 610 mm 3 ft. 914 mm 3 ft. 914 mm 6 ft. 1.8 m 4 ft. 1.2 m 9 ft. 2.7 m V1 + H1+ H2 = 50 ft. (15.2 m) Maximum H1 + H2 = 17 ft. (5.2 m) Maximum V1 = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY H1 H2 V1 H1 V1 Figure 7.3 Figure 7.4 Top Vent - Horizontal Termination Top Vent - Horizontal Termination One Elbow Two Elbows Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re. Note: The 6000 series fi replaces can adapt to SLP series vent pipe, if desired. When venting off the top of the unit, use a DVP-2SL adapter and a minimum 48 inch vertical section of SLP series vent pipe. After the 48 inch vertical section, the venting table rules must be followed. The fi rst 48 inch vertical section is NOT counted as part of the vertical components in the table. It is still counted as part of the overall maximum run. All venting table rules for the vent run must still be followed. Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal Fire Risk. • When using DVP-HRC-SS and DVP-HRC-ZCSS termination caps on top vented fi replaces, a 6 inch minimum vertical vent section is required before installing fi rst elbow. WARNING WARNING E. Vent Diagrams V1 Minimum H1 Maximum 6 inches 152 mm 3 ft. 914 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 6 ft. 1.8 m 3 ft. 914 mm 9 ft. 2.7 m 4 ft. 1.2 m 12 ft. 3.7 m V1 + H1 = 40 ft. (12.2 m) Maximum H1 = 20 ft. (6.1 m) Maximum V1 = 6 inches (152 mm) Minimum Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08 25 Figure 7.5 Top Vent - Horizontal Termination - (continued) Three Elbows H2 H1 V2 V1 V1 Minimum H1 Maximum V2 Minimum H2 Maximum V1 + V2 Minimum H1 + H2 Maximum 6 in. 152 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 1-1/2 ft 457...
Эта инструкция также подходит к моделям:Камины - 6000GCF-IPI (3.25 mb)