|
Фрагмент инструкции
28. Replace glass frame assembly. 29. Reinstall top and bottom louvers. 30. Test operation of fireplace once again. Allow the fireplace to operate for at least 10 minutes and check flame coloration. Flames on rear of burner should be yellow without any orange-colored tip. Minor adjustment of the air shutter may be necessary to "tune in" the proper flame color. Model AIR SHUTTER SETTINGS BURNER ORIFICE Opening "A" Propane/LP Orifice DVD32 1/4" (6.4 mm) #56 DVD36 1/4" (6.4 mm) #55 DVD42 5/16" (7.9 mm) 1.45 mm DVD48 5/16" (7.9 mm) #52 “A” REGULATOR FITTING NOTE: STAMPED WITH GAS TYPE SET FOR USE Maxitrol Valve Conversion Figure 59 Figure 60 DIRECT IGNITION PROPANE/LP GAS CONVERSION MAINTENANCE AND SERVICE PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean glass when glass is hot. It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process. Please ensure that your room is well ventilated -open all windows. It is recommended that you burn your fireplace for at least six (6) hours the first time you use it. If optional fan kit has been installed, place fan in the “OFF” position during this time. IMPORTANT: Turn off gas before servicing appliance. It is recommended that a qualified service person perform these checkups at the beginning of each heating season. • Clean Burner and Control Compartment Keepthecontrolcompartment,logs,andburnerareassurrounding the logs clean by vacuuming or brushing at least twice a year. Cleaning Procedure 1. Turn off pilot light at gas valve. 2. Remove glass front. (See Glass Removal) 3. Vacuum burner compartment. 4. Reinstall glass front. 5. Ignite pilot. (See Lighting Instructions) 6. Operate the pilot burner. If it appears abnormal call a service person. • Check Vent System The appliance and venting system should be inspected before initial use and at least annually by a qualified service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow. Glass Cleaning It will be necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-abrasive household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present. General Glass Information Glass Removal and Replacement (Figure 61) 1. Remove top louver, grasp louver and pull forward. 2. Lower bottom louver. 3. Release two glass frame clamps at bottom of firebox. 4. Remove glass frame. 5. Place glass frame onto firebox. 6. Attach two glass frame clamps at bottom of firebox. 7. Align clips on top louver with slots on front posts. Replace top louver into fireplace. 8. Close bottom louver. Figure 61 WARNING: Do not operate appliance with the glass front removed,crackedorbroken.Replacementoftheglassshould be done by a licensed or qualified service person. Only glass approved for use by the manufacturer in fireplace may be used for replacement. The glass replacement should be done by a licensed or qualified service person. WARNING: 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Undernocircumstancesshouldthisappliancebeoperatedwithout the glass front or with a broken glass front. Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a qualified service person. 4. Do not abuse the glass by striking or hitting the glass. Louver Removal and Installation 1. Remove top louver, grasp louver and pull forward. 2. Lower bottom louver. 3. Align clips on top louver with slots on front posts. Replace top louver into fireplace. 4. Close bottom louver. Page 44 23552-1-0607 PARTS LIST INDEX NO. PART NUMBER DESCRIPTION DVD32 DVD36 DVD42 DVD48 1 R-7654 R-7654 R-7654 R-7654 FLUE INSULATION 2 17425 17425 17425 17425 FLUE INSULATION RETAINER 3 R-7566 R-7566 R-7566 R-7566 INLET VENT ADAPTOR 4 R-7573 R-7573 R-7573 R-7573 INLET VENT GASKET 5 17155 17155 17155 17155 FLUE OUTLET ASSEMBLY 6 M163 M163 M163 M163 FLUE CONNECTOR GASKET 7 17142 17142 17142 17142 VENT COVER PLATE 8 R-7575 R-7575 R-7575 R-7575 VENT COVER PLATE GASKET 9 17141 17141 17141 17141 FLUE COVER PLATE 10 R-7574 R-7574 R-7574 R-7574 FLUE OUTLET GASKET 11 17301 17149 17149 17149 TOP STANDOFF (2 required) 12 17317 17317 17319 17320 TOP SHIELD 13 10554 10554 ...
Эта инструкция также подходит к моделям:Камины - DVD36FP3 (3.9 mb)
Камины - DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 (3.9 mb)
Камины - DVD42FP3 (3.9 mb)
Камины - DVD42FP5 (3.9 mb)