Инструкция по эксплуатации Dansons Group, модель FPP, IPP

Производитель: Dansons Group
Размер: 2.18 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Seal each vent section by injecting a liberal amount of HITEMP RTV silicone sealant into the gap. Use Diameter “PL” Vent If venting outside of shaded area. 4” 0’ 0’ 5’ 5’ 10’ 10’ 15’ 20’ 25’ 30’ 33’ Vent must have a support bracket every 5’ when on the exterior wall. If appliance is installed above 4,000’ elevation, always use 4” diameter venting. Vent height and run exceed the distance shown in the un-shaded region of chart. must not To achieve optimum performance, keep vent runs as short as possible. Especially on horizontal installations. Use or Diameter “PL” Vent, if venting in shaded area. 3” 4” Maximum venting height is 33’. Maximum horizontal offset is 10’. Use no more than 180 of elbows (two 90 elbows, or two 45 elbows & one 90 elbow, etc), plus termination. Canadian Comfort Industries V04 11 PELPRO OWNERS MANUAL Copyright 2004 Dansons Group Inc. EXHAUST SYSTEMS . . . Continued PELLET VENT TERMINATION: (Figures 7 & 8) Termination must be a minimum of 6” above the chimney (B) (note: the chimney must meet local codes for height above the roof or other obstructions) Must have an approved cap (to prevent water from entering) or a 45* elbow downturn If the termination is located on a windy side of house, an approved house shield is recommended to prevent soot from accumulating on the side of the house. Must not be located where snow or other materials will plug it. Must have a “Metal Seal Plate” or “Wall Thimble” at point (A) Figure 7 Figure 8 VENT TERMINATION CLEARANCES: • Horizontal terminations must protrude 12” from the wall, vertical terminations 24” Figure 9 A Minimum 4’ clearance below or beside any door or window which opens. B Minimum 1’ clearance above any door or window that opens. C Minimum 3’ clearance from any adjacent building. D Minimum 7’ clearance above any grade when adjacent to public walkways. NOTE: Vent may not terminate in covered walkway or breezeway. E Minimum 2’ clearance above any grass, plants, or other combustible material. F Minimum 3’ clearance from any forced air intake of any other appliance. G Minimum 2’ clearance below eves or overhang. H Minimum 1’ clearance horizontally from combustible wall. X Must be a minimum of 36” above the roof and 24” above the highest point of the roof within 10’. A B 3’ 10’ 2’ x A A F 4 12” G OUTSIDE AIR Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS. Outside air is strongly recommended for all other installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures. Metal pipe, ONLY, either solid or flexible, must be used in all outside air installations.(B) NOTE: Non-metallic material MUST NOT BE USED for outside air installations. A wind shield, (C), over the termination of the outside air pipe or a 90 degree elbow or bend directed away from the prevailing winds MUST be used when an outside air pipe is installed through the side of a building. Keep the outside air pipe termination at least 1 foot away from the exhaust system termination. When outside air is taken from an existing chimney the exhaust system must not terminate in the same chimney. The outside air pipe on your stove is 2" OD. The outside air connecting pipe must be at least 2" ID The outside air connecting pipe must be as short and free of elbows as possible, and must fit over, (A), not inside, the outside air pipe on your stove. Through The Wall Kits Include: 3 FOOT PACKAGE – PART# ACFAKT3 10 FOOT PACKAGE – PART# ACFAKT10 1 – 2” Galvanized Hood c/w screen 1 – 2” Galvanized Hood c/w screen 1 – 2” Aluminum Flex Duct – 1 – 2” Aluminum Flex Duct – compressed 15” length, extends to 30” – 36” compressed 4’ length, extends to 120” 2 – 2” Worm Gear Clamps 2 – 2” Worm Gear Clamps NOTE: Available from your local Authorized Dealer or Dansons Group Inc. 1-877-303-3134 Figure 9 Canadian Comfort Industries V04 12 PELPRO OWNERS MANUAL Copyright 2004 Dansons Group Inc. FREESTANDING STOVE INSTALLATION STOVE PLACEMENT: Stove must be placed so that no combustibles are within, or can swing within (i.e. drapes doors), 36” of the heater. If the stove is placed in a location where the ceiling height is less than 7’, it must follow the requirements in the section “Alcove Installation”. Stove and floor protection must be installed on a level secure floor FLOOR PROTECTION REQUIREMENTS: The stove must be installed on a non-combustible floor protector (i.e. sheet steel with cement, tile or slate) extending the full width and depth of the stove and extending 6” in front of the stove. Floor protector needs to be a minimum of 24.5” deep X 30.5” wide and must be a minimum of .018” thick (26 gauge). Must extend under and 2” to each side of chimney tee (if used). MINIMUM CLEARANCES TO COMBUSTIBLES (FIGURES 10 – 15) 1” From Back Of Heater To Combustibles 3” From PL Vent to Combustibles 2” From Side of Heater to Combustibles 1” From Back Corner of Heater to Combustibles 6” Non Combustible Surface I...

Эта инструкция также подходит к моделям:
Камины - FPP Freestanding (2.18 mb)
Камины - IPP Bay View Insert / Built-In (2.18 mb)
Камины - IPP, FPP (2.18 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории