Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации Hampton Direct, модель H25-NG1, H25-LP1

Производитель: Hampton Direct
Размер: 4.01 mb
Название файла: e835bc36-cf80-484c-8199-24b356787174.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


flex liner to the vent terminal ensuring that the flex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel). 4) Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel). NOTE: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional. Note: The pipe seam should be facing down. Note: To make the installation more aesthetically pleasing, we recommend framing out a square that the cap can be mounted on. must be used to ensure that the termination is not recessed into the siding. For vinyl siding standoff installation refer to the Dura-Vent Termination instructions. 5) Slide the partially connected pipe and vent terminal assembly through the wall thimbles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners. Note: The four screws provided for the vent cap should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings. 6) A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff. 7) Stretch the 4" dia. flex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar. 8) Cut the 4" dia. flex liner to the desired size. Hint: leave an extra 12" to 16" of length, this will make the final assembly easier to work with. 9) Secure the 4" dia. flex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel). 10) Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall. 11) Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. flex liner. 12) Install the spring spacers onto the pipe sections. 13) Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14) Attach the 45o elbow onto the starter collar by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" (black) screws. 15) Attach the pipe section to the 45o elbow by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall. 16) Attach the 90oelbow onto the pipe section by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" screws (black). 17) Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjustable pipe sections to cover the joint of the telescopic section.) The flex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pac and/or high temperature silicone and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down. 18) Install the trim collar over the starter collar and secure with a #8 x 1/2" screw (black). If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint. Hampton® H25-1 Direct Vent Freestanding Gas Stove INSTALLATION RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES MINIMUM HORIZONTAL TERMINATION INSTALLATIONS Planning Your venting Installation See the "Exterior Vent Terminatal Locations" NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met. You will require the following components with your new Hampton® Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass Pipe Length (max. 18") Part (6-5/8" Dia) (4" Dia.) Decorative Wall Trim Part #640-545/P Horizontal Terminal Part# 640-530/P Wall Thimble Part # 946-202 (required for combustible walls) Vinyl Siding Standoff (Optional) Part #946-205 Adapter Part #946-219/P (required) or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover. section for requirements. The H25 is approved for a minimum horizontal termination with the FPI Riser Vent Kit. See the diagram for minimum and maximum pipe lengths. When planning your installation, it will be nec- essary to select the proper length of vent pipe for your particular requirements. Determine the minimum clearance to combustibles from t...

Эта инструкция также подходит к моделям:
Камины - H25-LP1 Propane (4.01 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории