-replace. Pilot goes out when System is not correctly -purge the gas line with the glass door open. the gas knob is re-purged. leased. Out of propane gas. -fill the tank. The gas valve has Pilot flame is not large -turn up the pilot flame. an interlock device enough which will not allow the pilot burner to Pilot flame is not engulfing -gently twist the pilot head to improve the flame pattern around the be lit until the ther the thermocouple. thermocouple. mocouple has Thermocouple shorting / -loosen and tighten thermocouple. cooled. Allow approximately 60 faulty. -clean thermocouple and valve connection. seconds for the -replace thermocouple. thermocouple to Faulty valve. -replace. cool. Pilot burning; no gas to main burner; gas knob is on 'HI'; wall switch / thermostat is on. Themostat or switch is de--connect a jumper wire across the wall switch terminals; if main fective. burner lights, replace switch / thermostat. Wall switch wiring is defec--disconnect switch wires & connect a jumper wire across terminals tive. 1 & 3; if the main burner lights, check the wires for defects and / or replace wires. Main burner orifice is plugged. -remove stoppage in orifice. Faulty valve. -replace. Vent safety switch has opened. -Vent has become blocked or disconnected. Correct. See Figure 2. (Tripped) Hi Limit switch has opened. (Tripped) -Unit has overheated. See Figure 2 Pilot will not light. No spark at pilot burner -check if pilot can be lit by a match -check that the wire is connected to the push button ignitor. -check if the push button ignitor needs tightening. -replace the wire if the wire insulation is broken or frayed. -replace the electrode if the ceramic insulator is cracked or broken. -replace the push button ignitor. Out of propane gas -fill the tank. Spark gap is incorrect -spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger tight plus 1/4 turn). No gas at the pilot burner -check that the manual valve is turned on. -check the pilot orifice for blockage. -replace the valve. -call the gas distributor. W415-0275 / C / 09.23.05 SYMPTOM PROBLEM TEST SOLUTION SYMPTOM PROBLEM TEST SOLUTION Pilot goes out Gas piping is undersized. -turn on all gas appliances and see if pilot flame flutters, diminwhile standing; ishes or extinguishes, especially when main burner ignites. Monitor Main burner is in appliance supply working pressure. 'OFF' position. -check if supply piping size is to code. Correct all undersized piping. Flames are con-Unit is over-fired or undersistently too large fired. or too small. Carboning occurs. PI AB PILOT NOLOT HILO FF O -check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI". Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI". AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution. Carbon is being deposited on glass, logs or combustion chamber surfaces. Air shutter has become -ensure air shutter opening is free of lint or other obstructions. blocked Flame is impinging on the -check that the logs are correctly positioned. logs or combustion cham- -open air shutter to increase the primary air. ber. -check the input rate: check the manifold pressure and orifice size as specified by the rating plate values. -check to ensure proper venting action White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber surfaces. -clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glass may become permanently marked. Exhaust fumes smelled in room, headaches. Fireplace is spilling. - check for chimney blockage - check that chimney is installed to building code. - room is in negative pressure; increase fresh air supply. Main burner flame is a blue, lazy, transparent flame. Not enough combustion air -room is in negative pressure; increase fresh air supply Remote wall switch is in "OFF" Wall switch is mounted upside down - reverse. position; main burner comes on when gas knob is turned to "ON" position. Faulty valve. Remote wall switch is grounding. Remote wall switch wire is grounding. - replace. - replace. - check for ground (short); repair ground or replace wire. W415-0275 / C / 09.23.05 Wolf Steel Fireplace Service HistoryThis fireplace must be serviced annually depending on usage. Date Service TechnicianName Service Performed Special ConcernsDealer Name Wolf Steel Fireplace ...

Эта инструкция также подходит к моделям:
Камины - BGNV36P (2.64 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории