Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Napoleon Fireplaces, модель HCD36MH

Производитель: Napoleon Fireplaces
Размер: 438.14 kb
Название файла: Lennox_Hearth_HCD_Care_Operation_725038M.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


When lighting your fire, a little smoke may escape into the room – more likely if the chimney is cold. To correct this, hold a lighted newspaper up inside the firebox near the open flue damper. This will turn around any downdraft and clear the flue of cold air. As your log fire burns below, the updraft will improve as the chimney heats up. 3. Is your fire too far forward? Move it toward the back with your poker. Keep the fire well within the confi nes of your fuel grate. 4. Keep your fire up on the grate and the refractory below free of excessive ashes. The fire needs plenty of air movement around the logs. 5. If smoking occurs an hour or two after lighting the fire, perhaps your well-insulated house is too airtight and there is scarcely any way for replacement air to enter and feed the fire. Check to see if your outside combustion air kit (if installed) is open. Check outside to ensure no obstructions are in front of exterior air entry. Open a window slightly, open doors to one or two rooms and see if this stops the smoking. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 6. 6. draft – and smoking. 7. Is your wood fuel too wet or unseasoned? Or does it contain some chemical substance that causes sputtering, smoking and toxic fumes? 8. Figure 5 illustrates the correct height of your chimney top. It is unlikely that your installation does not adhere to the installation instructions. However, if not correct, you could experience an unusual downdraft. Usually, the best solution is to increase the chimney height. This may also be necessary if nearby trees, adjoining roof lines or a hill is causing a downdraft condition. 9. Remember, your fireplace is not intended to heat your entire home. Figure 5 Less Than 10' 3' Min 2' Min. 10' 3' Min WARRANTY • This fireplace is covered by a limited warranty detailed separately from this document. • Retain this manual. File it with your other documents for future reference. PRODUCT REFERENCE INFORMATION If you encounter any problems or have any questions concerning the installation or application of this system, please contact your distributor or installer. For the number of your nearest Superior dealer, please call 1-800-953-6669. LHP 1110 West Taft Avenue Orange, CA 92865 Your Fireplace's Model Number REPLACEMENT PARTS A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer. Normally, all parts should be ordered through your Superior distributor or dealer. Parts will be shipped at prevailing prices at time of order. When ordering repair parts, always give the following information: 1. The model number of the appliance. 2. The serial number of the appliance. 3. The part number. 4. The description of the part. 5. The quantity required. 6. The installation date of the appliance. Your Fireplace's Serial Number ________________________________________ The Date On Which Your Fireplace Was Installed ___________________________ Your Dealer's Name ________________________________________________ ACCESSORY COMPONENTS Louver Kit A decorative louver kit is available to enhance and beautify the front face of your fireplace. This kit is designed to attach directly to the fi replace front face over the standard louvers. They are available in a bright brass fi nish. (ref. Form #750,112M) Brass Louver Kit 19M15 FLK36-B NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. ACCESSORY COMPONENTS Bi-Fold Doors 20M30 FDBD36-B Bi-Fold Doors Your fireplace is fitted standard with beautiful bi-fold doors. Model FDBD36-B doors have a handsome bright brass fi nish. To ensure warranty and to prevent a potential fire hazard, do not use any other doors on these appliances. Brass Exterior Trim Kit 19M16 FETK36-B Exterior Trim Kit A decorative exterior trim kit is available for use with this fireplace. This kit is designed to attach to the fireplace front face around the firebox opening. It is available in a beautiful bright brass finish to provide a dramatic enhancement to the appeal of the fireplace in the home. (ref. Form #750,113M) ON/OFF Wall Switch Kit This ON/OFF wall switch kit can be used in place of the standard variable speed wall switch (see Page 8). This switch provides single speed ON/OFF operation of the blower. Install the ON/OFF wall switch in a convenient location near the fi replace. White Wall Switch Kit Cat. No. Model No. Description 85L87 FWSK ON/OFF Wall Switch Kit Set of 6 Louvers REPLACEMENT PARTS - MODEL HCD36MH PAINT8 4 3 5 2 1 6 910 Variable Speed Wall Mounted On/Off Switch. Included w/FBK-200 Only (or sold separately). 11 Blower No Description Part No. Qty. Fireplace Assembly -- 1. Firescreen 36L89 2 2. Rod, Screen H3610 2 3. Refractory, Side, Right 88L72 1 4. Refractory, Side, Left LB-98316B 1 5. Refractory, Rear LB-98317B 1 6. Refractory, Bottom LB-98315B 1 7. Grate 87L26 1 8. Paint, Touchup, Black, FTPK-B H4353 1 9. Blower, FBK-100, Single Speed (blower only) 80L84 1 10. Blower, FBK-200, Variable Speed (blower & wall rheostat) 80...

Эта инструкция также подходит к моделям:
Камины - HCD36MH (438.14 kb)
Камины - HCD36MH (438.14 kb)
Камины - HCD36MH (438.14 kb)
Камины - HCD36MH (438.14 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории