Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks. A. Mix a 50% dish soap, 50% water solution. B. Light the appliance (refer to safety and lighting instructions on page 17). C. Brush all joints and connections with the soapy water solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” position. Either tighten or refasten the leaking connec- tion and retest as described above. TPTH TP TH Red Wht Red Blu * For On/Off Switch Attachment. * Blk Blk Figure 14 Figure 15 Optional Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. OptionalON/OFFRocker Switch Door Switch Thermopile TPTH TP TH Red Blk Wht Red Blu Factory Wired Field Wired Step 8. Installing the Optional Forced Air Blower Kit Wiring – An electrical outlet box is provided for the installation of the FAB-1100 forced air blower kit (optional). Electrical power must be provided to this box to operate the blower. Route a 3-wire, 120Vac power line with control switch to the lower right rear corner of the appliance. Make connections to the receptacle as shown in Figure 16. IMPORTANT: Ground lead must be connected to the green screw located on the junction box cover plate. Failure to do so will prevent the appliance from operating. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70- latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code.) NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.8 Figure 16 Note:Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet. White (Supply) Black (Supply) BipolarTerminal Screw Blower (Lower) Outlet Black Wire MatingConnectors Red Wire 120 Vac 60 Hz Blower Wiring Diagram } OFF/ON Blower Wall Switch To Fuse or Circuit Breaker 120V AC 60Hz Fireplace Junction Box Black White Receptacle Ground Wire Connection Figure 17 Burner Top View Ember Chunks In This Confinement No Rockwool Material Behind This Point Keep Both Of These Five Hole PatternAreas Free Of Rockwool Materials Front Evenly Spread Dime Sized Pieces Of Rockwool Over 85% Of This Area (Small Burner Holes) The forced air blower kit may be mounted at initial appliance installation or at any time thereafter. Follow the instructions provided with the blower kit. Finished Wall Details It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.8 Figure 16 Note:Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet. White (Supply) Black (Supply) BipolarTerminal Screw Blower (Lower) Outlet Black Wire MatingConnectors Red Wire 120 Vac 60 Hz Blower Wiring Diagram } OFF/ON Blower Wall Switch To Fuse or Circuit Breaker 120V AC 60Hz Fireplace Junction Box Black White Receptacle Ground Wire Connection Figure 17 Burner Top View Ember Chunks In This Confinement No Rockwool Material Behind This Point Keep Both Of These Five Hole PatternAreas Free Of Rockwool Materia...

Эта инструкция также подходит к моделям:
Камины - STANDARD SERIES CF5500-CMN (598.98 kb)
Камины - STANDARD SERIES CF5500-CMN (598.98 kb)
Камины - STANDARD SERIES CF5500-CMN (598.98 kb)
Камины - STANDARD SERIES CF5500-CMN (598.98 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории