Ensurethethimblepenetratestheroofopening. Thethimblemustextendcompletelythroughthe ceiling or roof cavity to the outermost plane of the roof. Use thimble extension SVTE26 when thedistance betweentheoutsideoftheroofand the inside of the ceiling exceeds the height of the firestop thimble. The thimble provides for zero clearances to combustibles and must be used at the ceiling/roof in manufactured homes with Secure Vent double wall vent sections. Maintain 1 in. (25.4 mm) clearance between the thimble and the outer pipe of the secure vent chimney system. See Figure 21 (Page 16) for pitched roofs or flat roofs with flat ceilings or Figure 20 for pitched roofs with cathedral ceilings. 14" Min. (SV-FSTFE) Can Be UsedIf A Header Is Constructed At This Point Outer Pipe OfChimney Use correct firestopthimble depending on thepitch of the interiorceiling. Note: Regular Thimble Figure 20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Trim Thimble/ Extension To Desired Length And Pitch At The Roof Line 14" Min. Pitched Roof Pitched Roof Bow Roof 14" Min. Outer Pipe Of Chimney Outer Pipe Of Chimney Outer Pipe OfChimney14" Min. Firestop Thimble Extension 13" FirestopThimble FirestopThimble Thimble SV-FSTFE Figure 21 Note: Trim Thimble/ Extension To Desired Length And Pitch At The Roof Line 14" Min. Pitched Roof Pitched Roof Bow Roof 14" Min. Outer Pipe Of Chimney Outer Pipe Of Chimney Outer Pipe OfChimney14" Min. Firestop Thimble Extension 13" FirestopThimble FirestopThimble Thimble SV-FSTFE Figure 21 Support the vertical vent run sections Note -Properventingsupportisveryimportant. The weight of the vent must not be supported by the fireplace in any degree. Support the vertical portion of the venting system every 8 feet (2.4 m) above the fireplace vent outlet. One method of support is by utilizing field provided support straps (conventional plumber's tape). Secure the plumber's tape to the framing members with nails or screws. Loop the tape around thevent,securing theends ofthe tapeto the framing. If desired, sheet metal screws #6 x 1/2" length may be used to secure the support straps to the vent pipe. See Figure 22. Blocking Support Straps (Plumber's tape) 8 feet (2.4 m) Maximum 1 inch (25.4 mm) minimum clearance to combustibles Figure 22 Another method, where the vent is not adjacent to a wall, is illustrated in Figure 23. Here, support straps (96K93) and support plates (96K92) can be used to support the weight of the vent. vSV4.5VF Firestop / spacer uSV4.5SU Support Strap 8 ft. (2.4 M) Maximum uSV4.5SP Support Plate Ceiling Framing uSecured to Vent with Appropriate Fasteners 1” (25.4 mm) Minimum Clearance to Combustibles vWhen using secure Flex, use Firestop/Spacer SF4.5VF SV4.5FA or SV4.5FB Flashing and SV4.5SC Storm Collar SV4.5CGV-1 Termination Figure 23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. F.Changeventdirectiontohorizontal/inclined run -At transition from or to a horizontal / inclined run, install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element. Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking any of the previously connected vent sections. See Figure 24. 7-5/8” (194 mm)4-13/16 (122 mm) Swivel Joint (360° swivel) SV4.5E45 45° Elbow) Swivel Joint (360° swivel) SV4.5E90 90° Elbow) (206 mm) 8-1/8" Figure 24 G.Continueinstallationofhorizontal/inclined sections -Continue with the installation of the straightventsectionsinhorizontal/inclinedrun as described in Step C. Install support straps every 5 feet (1.52 m) along horizontal / inclined vent runs using conventional plumber’s tape. See Page 20, Figure 33. It is very important thatthehorizontal/inclinedrunbemaintained in a straight (no dips) and recommended to be in a slightly elevated plane, in a direction away from the fireplace of 1/4"riseperfoot(20 mm per meter) which is ideal, though rise per foot run ratios that are smaller are acceptable all the way down to at or near level. Use a carpenter’s level to measure from a constant surface and adjust the support straps as necessary. Use a carpenter’s level to measure from a constant surface and adjust the support straps as necessary. H. Frame roof opening -Identify location for vent at the roof. Cut and/or frame opening per Roof Framing Chart and Figure 25. C D Framing Dimensions for Roof Inches (millimeters) Pitch C D 0/12 10-1/2 in. (267 mm) 10-1/2 in. (267 mm) 6/12 10-1/2 in. (267 mm) 12 in. (305 mm) 12/12 10-1/2 in. (267 mm) 17 3/4 in. (451 mm) Figure 25 - Roof Framing I. Install the roof flashing -Extend the vent sections through the roof structure. Install the roof flashing over the vent section and position such that the vent column rises vertically (use carpenters level - see Figure 26 ). Nail along perimeter to secure flashing or adjust...
Эта инструкция также подходит к моделям:Камины - MILLIVOLT SDVPF-N-B (4.88 mb)
Камины - MILLIVOLT SDVPF-N-B (4.88 mb)
Камины - MILLIVOLT SDVPF-N-B (4.88 mb)
Камины - MILLIVOLT SDVPF-N-B (4.88 mb)