Войти:
Оценок - 5, средний балл: 3.8 ( )

Инструкция по эксплуатации Lennox Hearth, модель Adagio ADAGIO-MN

Производитель: Lennox Hearth
Размер: 6.06 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


No. Model Description H5773 ADAGIO-AG Arch Black H5774 ADAGIO-PF Arch Br. Nickel Cat. No. Model Description H5775 ADAGIO-IG Iron Gates H5776 ADAGIO-CPD Copper Gates Gated Facades Copper and Iron Gates 12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 13 Step 3. Install the Vent System General Information These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CSA-B149 in Canada. These fireplaces are designed, tested and listed for operation and installation with, and only with, Secure Vent™ Direct Vent System Components, Secure Flex™ Flexible Vent Components manufactured by Security Chimneys International and Z-FLEX™ Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster Canada Limited. These approved vent system components are labeled for identification. DO NOT use any other manufacturer's vent components with these appliances. Vertical (Straight) Installation Determine the number of straight vent sections required. 4-1/2" (114 mm), 10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2" (876 mm) and 46- 1/2" (1181 mm) net section lengths are available. Plan the vent lengths so that a joint does not occur at the intersection of ceiling or roof joists. Refer to the Vent Section Length Chart. These fireplaces must be vented directly to the outside. The vent system may not service multiple appliances, and must never be connected to a flue serving a solid fuel burning appliance. The vent pipe is tested to be run inside an enclosing wall (such as a chase). There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe. Select Venting System - Horizontal or Vertical With the appliance secured in framing, determine vent routing and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Refer to the section relating to your installation. A list of approved venting components are shown in the tables on Page 30. Vertical Termination Systems (Roof) Figures 17, and 23 through 25 on Pages 14 and 16 and their associated Vertical Vent Tables illustrate the various vertical venting configurations that are possible for use with these appliances. Secure Vent pipe applications are shown in these figures; Secure Flex pipe may also be used. A Vertical Vent Table summarizes each system’s minimum and maximum vertical and horizontal length values that can be used to design and install the vent components in a variety of applications. Both these vertical vent systems terminate through the roof. The minimum vent height above the roof and/or adjacent walls is specified in ANSI Z223.1-(latest edition) (In Canada, the current CAN/CSA-B149 installation code) by major building codes. Always consult your local codes for specific requirements. A general guide to follow is the Gas Vent Rule (refer to Figure 6 on Page 8). SV4.5HT -2 T ermination SV4.5F A OR SV4.5FB Flashing AND SV4.5SC STORM COLLAR . SV4.5VF Firestop/Spacer SV4.5L6/12/24/36/48 V ent Sections 40' Max. (12.2 M) 6' Min. (1.8 M) 1" (25.4 mm) Minimum Clearance to Combustibles . Whe n using Secure Flex, use Firestop/Spacer SF4.5VF Figure 12 Step 2. Routing Gas Line Route a 1/2" (13 mm) gas line along the inside of the left side framing as shown in Figure 12. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve. (See Step 7 on Page 24). 6-1/8" (156 mm) *1-7/8" (65 mm) Right Side Front Corner of Fireplace Framing * Measured from the top of platform that unit is installed on to pipe center (see Figure 9) NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 13 VENT SECTION LENGTH CHART Nominal Section Length (inches) 6 12 24 6 48 TOTAL QTY Net Section Length (inches) 4-1/2 10-1/2 22-1/2 4-1/2 46-1/2 Height of Vent Number of Vent Sections inches ft 144 12 1 0 0 0 3 4 150 12.5 0 1 0 0 3 4 154.5 12.875 1 1 0 0 3 5 160.5 13.375 0 2 0 0 3 5 172.5 14.375 0 0 0 5 0 5 177 14.75 1 0 0 5 0 6 183 15.25 0 1 0 5 0 6 186 15.5 0 0 0 0 4 4 190.5 15.875 1 0 0 0 4 5 196.5 16.375 0 1 0 0 4 5 205.5 17.125 0 1 1 5 0 7 207 17.25 0 0 0 6 0 6 211.5 17.625 1 0 0 6 0 7 217.5 18.125 0 1 0 6 0 7 229.5 19.125 0 0 1 6 0 7 232.5 19.375 0 0 0 0 5 5 237 19.75 1 0 0 0 5 6 241.5 20.125 0 0 0 7 0 7 246 20.5 1 0 0 7 0 8 252 21 0 1 0 7 0 8 264 22 0 0 1 7 0 8 276 23 0 0 0 8 0 8 279 23.25 0 0 0 0 6 6 280.5 23.375 1 0 0 8 0 9 283.5 23.625 1 0 0 0 6 7 289.5 24.125 0 1 0 0 6 7 301.5 25.125 0 0 1 0 6 7 310.5 25.875 0 0 0 9 0 9 315 26.5 1 0 0 9 0 10 325.5 27.125 0 0 0 0 7 7 330 27.5 1 0 0 0 7 8 336 28 0 1 0 0 7 8 345 28.75 0 0 0 10 0 10 349.5 29.125 1 0 0 10 0 11 372 31 0 0 0 0 8 8 376.5 31.375 1 0 0 0 8 9 379.5 31.625 0 0 0 11 ...

Эта инструкция также подходит к моделям:
Камины - Adagio ADAGIO-EN (6.06 mb)
Камины - Adagio ADAGIO-MP (6.06 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории