Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Lennox Hearth, модель Elite Series E36ODGPE-H

Производитель: Lennox Hearth
Размер: 782.34 kb
Название файла:

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Any safety guard or screen removed for servicing the appliance must be replaced prior to operating the appliance. Table 1 Tables 1 shows the units' gas orifice size for the elevations indicated. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa). Access Cover Control Valve Refractory Cover The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE. Units are tested and approved for elevations of 0 to 4500 feet (0 to 1372 meters). For elevations above 4500 feet (1372 meters), install the unit according to the regulations of the local authorities having jurisdiction and, in the USA, the latest edition of the National Fuel Gas Code (ANSI Z223.1) or, in Canada, the latest edition of the CAN1-B149.1 and .2 codes. Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas. The minimum manifold pressure on low is 2.2 in. w.c. (0.55 kPa) for natural gas and 6.3 in. w.c. (1.57 kPa) for LP/Propane gas. Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water. Ne pas se servir de cet appareil s'il a ete plonge dans l'eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l'appareil et remplacer toute partie du systeme de controle et toute commande qui ont ete plonges dans l'leau. Test gage connections are provided on the front of the electronic gas control valve (identified OUT for the manifold side and IN for inlet pressure. A 1/8" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner. Minimum inlet gas pressure to these appliances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment. Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane. Model No. Orifice size Elevation Feet (meters) Natural Gas Propane E36ODG 0.1405" (#28) 0.0785" (#47) 0-4500 (0-1372) E42ODG 0.1405" (#28) 0.0785" (#47) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 2 Dexen Electronic Gas Valve Maintenance The appliance should be thoroughly inspected before initial use and at least annually by a qualified service technician. However, more frequent periodic inspections and cleanings should be performed by the homeowner. Homeowner must contact a qualified service technician at once if any abnormal condition is observed. Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper operation of the appliance after servicing. IMPORTANT: TURN OFF GAS AND ANY ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. Battery Replacement The intermittent ignition system operates on 3 volts provided by two (2) "D" cell batteries. The batteries are located in a pack installed within the J-Box, behind the stainless ON/OFF switch panel. Refer to Figure 3. Note: All batteries loose voltage when frozen or left for prolonged periods. It may be wise to remove batteries during extended periods of disuse. Pilot Stage Terminal Pressure-Tap (Inlet) Pilot Gas Outlet Supply GasInlet Pressure-Tap(Manifold) Burner Stage Terminal Ground (TP) PILOT OUT VENT LO THTP TH TPHI IN INGas Outlet To Burner Regulator Mounting Screw OPERATION AND CARE OF YOUR APPLIANCE Appliance operation may be controlled by a remotely located wall switch. Gas Controls/Control Compartment Access The gas controls can be found beneath the bottom refractory. Remove the bottom refractory by lifting it up. Remove the access cover (refer toFigure 1). All Models To light these appliances refer to the detailed lighting instructions found in both English and French on pages 14 and 15of these instructions respectively. The appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. See Figure 1 for its location...

Эта инструкция также подходит к моделям:
Камины - Elite Series E36ODGNE (782.34 kb)
Камины - Elite Series E36ODGPE (782.34 kb)
Камины - Elite Series E42ODGNE (782.34 kb)
Камины - Elite Series E42ODGNE-H (782.34 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории