Войти:
Оценок - 4, средний балл: 3.3 ( )

Инструкция по эксплуатации Jotul, модель GZ 550 DV II

Производитель: Jotul
Размер: 2.06 mb
Название файла: m-acadia.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Label B - apply to the fireplace Rating Plate as designated on the plate. WARNING: If appropriate, be sure to unplug the blower before proceeding with this conversion. Fuel Conversion Procedure 1. Remove the Glass Frame: • Follow the removal procedure detailed on page 1. 2. Empty the firebox: • Lift and remove the Fettle and Logset package. CAUTION: THE LOGS ARE FRAGILE. Handle them with care and set aside out of the way. • Remove the Burner Skirt. Lift and tilt it to clear the firebox opening. See fig. 28. 3. Change the Burner Orifice: • Loosen the locknut on the Air Shutter Stem, located under the firebox floor to the right of the Control Valve. Pull the stem forward as far as it will go. This will allow you to disengage the Burner Assembly. See fig. 29. • Lift the rear of the Burner Tube and rotate slightly forward. Slide the tube back enough to disengage it from the Air Shutter and Burner Orifice, then lift out. See fig. 30. • Slide the Air Shutter back out of the way to expose the orifice. See fig. 31. Using a .” open end wrench or deep well socket remove the burner orifice and replace with the appropriate orifice, supplied in the kit. 17 Figure 28. Lift the Burner Skirt up and out of the firebox. Figure 32. Pilot Orifice replacement. PILOT ASSEMBLY Pilot Hood Pilot Orifice Retainer Clip Figure 31. Move air shutter back to access the burner orifice. Burner Orifice Figure 29. Frame latch and air shutter stem location. Air Shutter Wingnut Pull Frame Spring Latch to release. Air Shutter Burner Tube Figure 30. Move shutter forward to disengage the burner tube assembly. . 4. Change the Pilot Orifice: • FROM WITHIN THE FIREBOX, disengage the Pilot Hood by releasing the retainer clip as shown in fig. 32. Using the 4 mm hex key supplied, unscrew the pilot orifice (counterclockwise). Replace with the appropriate orifice: #51 for Natural gas #30 for Propane Tighten new orifice into the base of the pilot assembly. • Replace Pilot Hood by pushing it into the base. 5. Replace the Burner Tube:. Slip the end of the tube into the Air Shutter and SLIDE TUBE FORWARD TO COMPLETELY COVER THE BURNER ORIFICE. 6. Adjust the Air Shutter: See fig. 33. • Slide the shutter BACK to open the inlet, slide FORWARD to close. The standard settings are: Natural gas - 1/4” open Propane -1/2” open • Tighten the wing nut on the Air Shutter Stem. • Replace the Burner Skirt. 7. Change the Regulator: See fig. 34. • Using a Torx T-20 screwdriver or small flat head screwdriver, remove the three specialty screws from the front of the valve regulator. • Remove the regulator tower and gasket. BE SURE TO REMOVE THE BLACK RUBBER GASKET FROM THE VALVE. • Install the new variable regulator tower with the new rubber gasket. Thoroughly tighten new regulator to valve body. 8. Apply the Conversion Labels: • Apply LABEL A to the cabinet floor so that it may be seen by anyone servicing the fireplace. • Apply LABEL B to the Rating Plate in the space provided. 9. Reassemble the fireplace, apply gas to the system and check for gas leaks including all gas lines before and after the valve. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. IMPORTANT: Correct gas pressure is essential for efficient and safe operation. It is important that the correct gas pressure be established at the time of the installation. For more details, see the Gas Pressure section of this manual on page 12. WHEN LIGHTING THIS APPLIANCE, ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE BACK COVER OF THIS MANUAL. Figure 33. Adjust Air Shutter as appropriate. Fully open position is shown here. Slide shutter forward to close. Be sure to remove the black rubber gasket from the valve. Apply small conversion notice label here. Figure 34. Valve Regulator replacement. Wall Thermostat Installation Use Jotul Thermostat #129706 or a 750 millivolt DC two-wire circuit thermostat to automatically control your fireplace operation. The thermostat should be placed in the same room as the heater, typically 5’ off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat. The thermostat should be connected to the Acadia using a minimum of 16 gauge wire with a maximum length of 35 feet of wire. Connect the two thermostat wire leads to the two lower terminals on the terminal block located to the right of the ON/OFF/T’STAT switch. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Figure 34. At the thermostat, the two wires should be connected to the two connections screw on the thermostat base plate per the manufacturer’s instructions. For thermostatic function, place the ON/OFF/TSTAT switch in the T-STAT position and the pilot flame must be lit. Figure 36. ZG550 Acadia Wiring Diagram ! "#$ "% "#$. &'#. "%". "&. ". #"". Remote Control The optional Jotul Remote Control can be installed on the Acadia gas fireplace. Using the wire supplied with the remote, connect the remote directly to the gas control valve. See fig. 36 Connect one rec...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории