Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Vermont Casting, модель ODGSR42A

Производитель: Vermont Casting
Размер: 770.22 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


NEVER obstruct the front opening of the appliance. This fireplace is not designed to be water tight. Therefore, when installing this unit against an exterior wall, the wall must be finished before setting unit in place. ODGSR Series Outdoor Gas Fireplace Fireplace Dimensions 39......" (1007mm) ......" (16mm) ......" (13mm) ......" .........." (822mm) 68 . ...... "(1740mm) 48......" (1232mm) 48...... " (1232mm) 36" (914mm) 40" (1016mm) 43......" (1111mm) RoughOpeningHeight 22" (559mm) .........." (572mm) ...." (559mm) Rough Opening Width 41" RoughOpeningDepth (1041mm) 14......" (362mm) 3......" (95mm) Low VoltageWire Access ...." (622mm) 8......" (210mm) ........" (165mm) ........" (191mm) Gas Line Access ......" (16mm) Recessed NailingFlange 3......" (95mm) 3......" (98mm) 14......" (362mm) Low VoltageWire Access Fig. 1 ODGSR36A specification and framing dimensions. Fireplace Dimensions 39......" (1007mm) ......" (16mm) 50" (1270mm) 50" (1270mm) ......" (13mm) ......" .......... " (1791mm) 35......" (895mm) 42" (1067mm) 46" (1168mm) 43......" (1111mm) RoughOpeningHeight 22" (559mm) .........." (572mm) .........." (667mm) Rough Opening Width 47" RoughOpeningDepth (1194mm) 14......" (362mm) 3......" (95mm) Low VoltageWire Access ...." (610mm) ........" (191mm) ........" (165mm) ........" (191mm) ......" (16mm) Recessed NailingFlange 3" (76mm) Gas Line Access 14......" (362mm) Low VoltageWire Access Fig. 2 ODGSR42A specification and framing dimensions. Screened Porch Installation ODGSR Series Outdoor Gas Fireplace The ODGSR may be installed safely and is design certified by CSA to be installed in a screened porch with these guidelines: Minimum porch area...............................96 sq. feet (9sq m) Minimum celing height ................................. 92" (2,337 mm) Minimum of two (2) walls must be screened Minimum top of screen height, side walls ....6'6" (1,981 mm) Minimum screen area .............................64 sq. feet (6sq m) Clearance to Combustibles Appliances Top ..........................................................0” (0 mm) Bottom.....................................................0” (0 mm) Side.........................................................0” (0 mm) Back ........................................................0” (0 mm) Perpendicular Sidewall ...........................0” (0 mm) Top of unit to ceiling ..........................36” (914 mm) Front of unit to combustibles.............36” (914 mm) Mantels\ WARNING: A 4" hood must be used if a mantel is to be installed. The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace. For the correct mounting height and widths refer to Figures 3a and 3b Noncombustible mantels and legs may be installed at any height and width around the appliance. A Side View B Y Z CFM146 Fireplace Top of Combustion Chamber Ref. Mantel Ref. Mantel From Top Shelf Depth of Comb. Chamber Y 8" (203mm) A 28" (711mm) Z 1..." (38mm) B 26" (660mm) CFM164 Mantel Leg Black Surround Face J F G HI Side of Combustion Chamber O N M L K CFM170 Ref. Mantel Leg Depth Ref. Mantel Leg From of Comb. Opening F 14" (356mm) K 14" (356mm) G 12" (305mm) L 12" (305mm) H 10" (254mm) M 10" (254mm) I 8" (203mm) N 8" (203mm) J 1..." (38mm) O 1..." (38mm) Fig. 3b Combustible mantel leg minimum installation. When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discoloration. Hearth A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth. Fig. 3a Mantel clearances. ODGSR Series Outdoor Gas Fireplace Framing and Finishing Check appliance to make sure it is levelled and properly positioned. The appliance should only be mounted on the following surfaces: • A flat combustible (burnable) surface. • A raised wooden platform. • A concrete block or other solid object placed beneath each of the four corners of the appliance. To mount the appliance: 1. Choose unit location. 2. Four (4) nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 4. FP549 Nail Top Standoffs Nail Side- Nailing Flanges Fig. 4 Adjustable drywall strip (nailing flange). Finishing CAUTION: All joints between the finished wall and the appliance surround (top and sides) may be sealed only with non-combustible material. Only noncombustible material can be applied as facing to the appliance surround (the black painted face). Finish the wall with the material of your choice. Refer to Figures 3a and 3b for specific clearances when installing a combustible mantel or other combustible projection. Gas Inlet & Manifold Pressures Natural LP Minimum Inlet Pressure 5.5” w.c. 11.0” w.c. Maximum Inlet Pressure 14.0” w.c. 14.0” w....

Эта инструкция также подходит к моделям:
Камины - ODGSR36A (770.22 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории