Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Desa, модель (V)DVF36TCLP(E)

Производитель: Desa
Размер: 2.04 mb
Название файла: 00f440f5-2f86-7494-45c5-c00e0904a78e.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


V1SWSITSINDV2L1DNGP. Electrode Make Connections with Wirenuts (Supplied) (Back View) Transformer Plug 120V AC To Receptacle Ignition Control Module 18 AWG Red Wire OFF PILOT ON LO HI PILOT EA16AI7TPTH TP TH Figure 31 - Wall Switch Wiring Diagram, Electronic Units Installation WALL SWITCH INSTALLATION The electronic version uses a 24 VAC current supplied from a transformer mounted on the ignition module and is prewired for easy connection to a wall switch (see Figure 31). The millivolt version uses a self generated millivolt current that allows you to activate the gas control valve directly without the use of normal household electricity (see Figure 32). Both versions are supplied with a wall switch kit for ready connection and mounting. WARNING: Do not wire remote wall switch to main power supply (Standard 120V household current). 1. To remove the louvers, simultaneously pull both top end spring latches towards the center of the appliance until they are disengaged from locating holes. Repeat for bottom spring latches and pull louvers outward. Reverse the procedure to install louvers back onto the appliance (see Figure 33, page 19). 2. Connect the 18 gauge wires from wall switch to the gas control valve terminals marked TH and TPTH or to the ignition module using the pigtails and wire nut connectors supplied with the appliance. Wall Switch (Supplied) OFF PILOT ON LO HI PILOT EA16AI7TPTH TP TH To Thermopile Route Millivolt Wires (Supplied) Through Gas Line Conduit Sleeve (Back View) Figure 32 - Wall Switch Wiring Diagram, Millivolt Units Note: If any of the original wire supplied must be replaced, use type 18 AWG-105° C (25 feet length maximum) or equivalent. CAUTION: Due to high temperatures, make sure wires are not touching upper firebox. Installation Continued Glass Locating Holes Recommended Blower Speed Control Location Spring Latch Figure 33 - Removing Louver Electrical Hookup for optional blower accessory Before blower accessory can be operated, the appliance outlet box must be properly connected to a standard 120 VAC power source. This must be done when the appliance is originally installed. Refer to Wiring Diagrams on page 31. An outlet box with two receptacles has been supplied for your convenience and is located on the lower right side of the appliance (see Figure 34). The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance behind the louvered opening (see Figure 33). You may test the blower for operation by turning the control knob clockwise just until it clicks on which is the full on position. Adjust the fan speed to the lowest setting (this should be no more than 1/4 of a turn clockwise). OPTIONAL Wireless hand-held REMOTE CONTROL Installation Note: If using an optional wireless hand-held remote control, the wall switch is no longer operational. NOTICE: Only use alkaline batteries (not included). Installing HRC100 Model Remote Control (Millivolt Models Only) 1. Remove lower louver access panel in fireplace (see step 1 of Wall Switch Installation, page 18). 2. Disconnect wall switch wires from terminals marked TH and TPTH (see Figure 32, page 18). 3. Slide 9-volt battery into clip on back of remote receiver and connect battery terminals to battery. Mount receiver onto bracket with clips provided (see Figure 35). 4. Connect white wire to control valve terminal TH and red wire to TPTH. Move remote select switch to REMOTE position. 5. Replace louvered access panel by following reverse of step 1 under Wall Switch Installation, page 18. 6. Remove battery cover on back of hand-held remote (see Figure 36, page 20). Remove and discard sensor tag. 7. Attach terminal wires to 9-volt battery. Place battery into housing. 8. Replace battery cover onto hand-held remote. 9. Set selector switch on receiver to OFF position if you will be away from the unit for an extended period of time. Plastic Mounting Clips 9-Volt Battery FRONTOFF PILOT ON LO HI PILOT EA16AI7TPTH TP TH Receiver Clip Gas Valve Terminal Wires For Optional Fan Kit From Blower Assembly White Red To Thermopile Figure 35 - Installing Remote Receiver (HRC100) Figure 34 - Connecting Blower Accessory to Power Supply Installing Skytech/WRC Model Remote Control (Electronic Models Only) 1. Remove lower louver access panel in fireplace (see step 1 of Wall Switch Installation, page 18). 2. If a wall switch was installed, it must be removed from ignition control circuit for remote to work properly. Remove wire nuts from switch connection at ignition control module. Using wire nut, connect transformer (blue) wire to remaining wire connected to control terminal marked P.SW (see Figure 36, page 18). 3. The receiver does not require a battery. To install, plug extension cord into one of the outlet receptacles on the outlet box. Plug receiver unit into extension cord and the ignition module into receiver unit (see Figure 37). 4. Replace louvered access panel by following reverse steps on page 18. 5...

Эта инструкция также подходит к моделям:
Камины - (V)DVF36TCRP(E) (2.04 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории