Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Desa, модель (V)KC42N

Производитель: Desa
Размер: 2.06 mb
Название файла: 5a3eb05c-8e49-4104-959f-be551c9388aa.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


4. Assemble the desired combination of pipe and elbows to the fireplace flue collar. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassemblies for convenience. 5. Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10 3/4" x 10 3/4" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9). Male Female Slots Locking Lugs Figure 8 - Vent Pipe Connections Vent Opening (Framing Detail) 10 3/4" (273 mm) 10 3/4" Inside Framing (273 mm) 10 3/4" (273 mm) 8 1/2" (216 mm) Combustible Wall Vent Opening Noncombustible Wall Figure 9 - Vent Opening Requirements Center of Hole 116239-01A VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 9 VENTING INSTALLATION INSTRUCTIONS Continued WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exterior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal between it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings. Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of standoff. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material. 7. Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12). 8. Carefully move fireplace, with vent assembly attached, towardwall and insert vent pipe into horizontal termination. The pipeoverlap should be a minimum of 11/4" (see Figure 13, page 10).. Vent Cap Figure 10 - Installing Horizontal Vent Cap (Noncombustible Exterior) Wood Screw Cut Siding Away to Fit Standoff Wood Screw Standoff Vent Cap Apply Mastic to All Four Sides Screws Figure 11 - Installing Siding Standoff (Combustible Exterior Wall) Firestop Vent Cap Horizontal (Horizontal Vent Pipe Termination) Screw Interior Wall Surface Wall Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe 116239-01A 10 VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) VENTING INSTALLATION INSTRUCTIONS Continued 9. Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13 for horizontal termination details. 10. Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secureunit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly. Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind Termination Apply Mastic to Outside Edge of Standoff Exterior Wall with Vinyl Siding 10 3/4" x 10 3/4" Framed Opening Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall Minimum Pipe Overlap 11/4" Wall Firestop Direct Vent Pipe Horizontal Termination Configurations Figures 14 through 18 show different configurations and alternativesfor venting with horizontal termination. Each figure includes a chartwith critical minimum and maximum dimensions which MUST be met.IMPORTANT:Rememberthatahorizontalrunofventingmust have a 1/4" rise for every 12" of run toward the termination. WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire.Operationofimproperlyinstalledandmaintained ventingsystemcouldresultinseriousinjury,property damage or loss of life. GROUND FLOOR INSTALLATION Recommended Applications: • Installation using cabinet surrounds • Through the wall using round or square termination (up to 12" horizontal pipe) • NOT FOR CORNER INSTALLATION Horizontal High Wind Square Termination Wall Firestop 45° Elbow Adjustable Pipe 12" Max. Square Termination Vertical (V) Horizontal (H) 32 3/4" min. 17" max. 45° Elbow Wall Firestop Exterior Portion of Wall Firestop (Round Termination Only) Round Termination Horizontal Rou...

Эта инструкция также подходит к моделям:
Камины - (V)KC42P (2.06 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории