Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Superior, модель 36" B-VENTED GAS APPLIANCES B-40REN

Производитель: Superior
Размер: 475.12 kb
Название файла: Lennox_Hearth_B40_Installation_700003.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-combustible Class 1 or Class 0 flexible duct. Outside Combustion Air Kits (with duct) 81L87 FOAK-4 (without duct) 81L88 FOAK-4LD Wall Switch Kit 85L87 FWSK Gas Conversion Kits WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE. LA CONVERSION DEVRA ETRE EFFECTUEE CONFORMEMENT AUX RECOMMANDATIONS DES AUTORITES PROVINCIALES AYANT JURIDICTION ET CONFORMEMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1B149.1 ET.2. Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation. Kit part numbers are listed below and the following steps detail the conversion procedure. Millivolt Conversion Kits Honeywell 75L28 — Natural to Propane 75L27 — Propane to Natural SIT H2021 — Natural to Propane H2022 — Propane to Natural Electronic Conversion Kits 75L29 — Natural to Propane 75L26 — Propane to Natural AVERTISSEMENT: CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR UNE AGENCE QUALIFIEE DE SERVICE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISES AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RESULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIEE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET EQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLETE JUSQU'A L'OPERATION DE L'APPAREIL CONVERTI EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L'EQUIPEMENT. Step 1. Turn off the gas supply to the appliance. Invert the flip cap so that the letters associated Remove the front glass door/frame (if used) from with the desired gas type are positioned closest to the appliance. the valve body. NG is for natural gas and LP is for propane. Tighten the flip cap by turning it clock- Step 2. Carefully remove the front log. Exercise wise. Replace the black thread-protecting cap. care as not to break the log. Step 3. Remove the access panel. Locate the screws securing the burner (tray) to the appli- Pressure ance. Remove the burner and retain the secur- Regulator ing screws. Millivolt Appliances Step 4. SIT Systems - See Figure 27and the Remove These Components instructions provided with the kit. Using a Torx T20, remove and discard the three pressure regulator mounting screws. Remove the pres- Figure 27 sure regulator, spring, poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque. Flip Cap Step 5. Honeywell Systems - See Figure 28 Thread and the instructions provided with the kit. Protector Remove the black thread-protecting cap. Remove the conversion flip cap by turning it Figure 28 counterclockwise. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 29 Pilot Orifice Step 6. All Millivolt Systems – Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. Step 7. Refer to Figure 29 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit. Figure 30 Figure 31 Figure 32 Figure 33 Step 12. Turn on gas supply and test for gas leaks. Step 10. Reassemble all removed components by reversing the procedures outlined in the preceding steps. Use pipe joint compound or Teflon tape on all pipe fittings before installing (ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds on flare fittings). Step 11. Attach apropriate conversion kit label (Figure 33 )to the rating plate on the appliance. See Figure 30and replace the pilot orifice as follows: Remove the ignitor assembly retain...

Эта инструкция также подходит к моделям:
Камины - 36" B-VENTED GAS APPLIANCES B-40REP (475.12 kb)
Камины - 36" B-VENTED GAS APPLIANCES B-40RMN (475.12 kb)
Камины - 36" B-VENTED GAS APPLIANCES B-40RMP (475.12 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории