Seal all joints between the black fireplace face and the wall covering with a heat-resistant material such as rock wool insulation or mortar. Be sure to use high temperature adhesive or mortar when anchoring brick, stone, or tile to the face of the fireplace. CLEARANCES To ensure a safe installation, the following must be carefully observed. 1. Sidewall Clearances: Clearances from the right or left side of the fireplace opening to any adjacent combustible wall should not be less than 7", facing the unit. 2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of the fireplace opening. Check to see whether man-made brick and stone are made of non combustible materials before using them on the face of the fireplace. Some of these products contain combustible materials. Combustible wall coverings such as paneling or wallboard may not overlap the black face of the fireplace. The space between the wall covering and the fireplace should be sealed with a heat resistant material such as rock wool insulation or mortar. NOTE: An “L” shaped steel lintel must be installed across the top of the firebox opening where facing materials such as brick or stone is used on the face of the firebox. It acts as a support/firestop. It should be attached to the face of the fireplace with screws and sealed to the fireplace with a heat-resistant sealer. 3. Mantel Clearances: We have provided 4 different situations to position your mantel. See Figure 5. 4. Floor Clearances: No clearance is required if the appliance is installed per these instructions. 5. Front Clearances: From the Front of the fireplace to any combustible materials should not be any less than 24”. FINISHING YOUR FIREPLACE 42" MIN. CLEARANCE TO CEILING 7" MIN. FIGURE 4 SIDE WALL CLEARANCE FROM FIREPLACE OPENING TO SIDE WALL NOTE: Adequate clearance around air openings must be maintained. Never cover any openings on the appliance with any type material. 24” CLEARANCE TO FRONT LEFT SIDE RIGHT SIDE Page 9 MANTEL PROFILES FOR ZERO CLEARANCE CABINET MUST BE FOLLOWED MANTELS WITH 3/4" BASE CEILING 2" 42" COMBUSTIBLE FP-BR10-ZC LOUVERS HOOD 10" 3/4" 3-1/2" 3" MATERIAL MATERIAL STAND OFF 2" COMBUSTIBLE FP-BR10-ZC 12" 2-1/2" 3/4" 3" 3-1/2" LOUVERS STAND OFF HOOD Bottom of 3/4" Base or Support Bottom of 3/4" Base or Support must be Flush with top of Unit must be at least 2-1/2" from top if mantel is 10" wide or less. of Unit if mantel is 10" wide or more. MANTELS WITH 2-1/2" BASE MATERIAL STAND OFF LOUVERS HOOD 2" COMBUSTIBLE FP-BR10-ZC 12" 3" SUPPORT 2-1/2" 6" Bottom of 2-1/2" Base or Support must be Flush with top of Unit if mantel is 12" wide or less. 2" COMBUSTIBLE MATERIAL STAND OFF FP-BR10-ZC 12" 3" 2-1/2" 2-1/2" Bottom of 2-1/2" Base or Support must be at least 2-1/2" from top of Unit if mantel is 12" wide or more. SUPPORT LOUVERS HOOD Page 10 INSTALLATION OF MODEL FP - BR10- ZC WITH OPTIONAL WOODEN MANTEL (1) When choosing the right location for your heater and mantel keep the following in mind: NOTE: Due to high temperatures, this heater should be located out of traffic and away from furniture and draperies. NOTE: Kit No. (PA KDMH10) Deluxe Wooden Mantel for FP-BR10-ZC. Kit No. (PA KDM10) Standard Wooden Mantel for FP-BR10-ZC CAUTION: THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODES, ANSI Z223.1/NFPA 54. NOTE: See page 18 for “Gas Pressure Check”. WARNING: YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE (2) Screen(s) can not be removed or altered (Position screen(s) in the closed position before leaving heater unattended). (3) Follow instructions for assembly of (Optional) Wooden Mantel. See instructions supplied with mantel. (4) After mantel has been assembled, slide the heater from the rear into the opening of the mantel. NOTE: Place a cloth or blanket over the front portions of the mantel as not to scar the wood. (5) Center the heater in the opening of the mantel. See Figure 6. (6) Fasten mantel to hearth by using ." wood screws. (7) Insert the nine (9) ." wood screws provided with mantel through slots on nailing flange and secure in place. See Figure 6. (8) Position mantel and fireplace into desired location. (9) To light the heater, see “Lighting Instructions” pages 19 through 30. Make sure you have the right gas valve for Natural or LP gas. NOTE: Hook gas supply line into heater. Check for leaks using soap and water, not an open flame. NOTE: When used as a bedroom fireplace, the unit must be attached to the wall. Use the angle provided with the mantel. Also the safety screen must be kept mechanically secured to the unit as it is when it leaves the manufacturer. Page 11 TOP MANTEL MANTEL BASE REAR OF HEATER 1/2" WOOD SCREWS (9) FIGURE 6 Page 12 INSTALLATION AFTER-MARKET MOBILE HOMES THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY LOCATE...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории