Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Monessen Hearth, модель B-VENT BBV400

Производитель: Monessen Hearth
Размер: 2.22 mb
Название файла: 62D4036_BBV_SBV400_9.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This may create a fire hazard. Only noncombustible materials (i.e. brick, tile, slate, steel or other materials with a UL fire rating of Zero) may be used to cover the black surface of the appliance. A 300° F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300° F minimum sealant material (General Electric RTV 103 or equivalent) must be used. VENT INSTALLATION WARNING Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. NOTICE Failure to follow these instructions will void the warranty. INSTALLATION PRECAUTIONS Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions. Only a qualified installer/service person should install venting system. The installer must follow these safety rules: • Wear gloves and safety glasses for protection. • Use extreme caution when using ladders or when on rooftops. • Be aware of electrical wiring locations in walls and ceilings. The following actions will void the warranty on your venting system: • Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by MHSC. • Installation other than permitted by these instructions. INSTALLATION PLANNING “B” VENT PIPE See venting installation instructions provided by the B- Vent manufacturer. NOTE: This APPLIANCE MUST BE INSTALLED using “B” vent type pipe that has been listed by a nationally recognized testing agency. Refer to B-Vent Pipe Sizing chart for proper elbow offset runs. Chimney centerline dimensions are referenced on Pages 6 & 7, Figures 2 & 3. • Minimum vertical chimney height - 8’ as measured from top of unit to top of termination. • Minimum vertical height - 40’ as measured from top of unit to top of termination. • Minimum chimney height with two (2) 90° elbows - 8’. • Elbow requirements: Allow a maximum of two (2) 90° elbows or four (4) 45° elbows per installation. NOTE: Two (2) 45° elbows = one (1) 90° elbow • Horizontal run must never exceed 50% of the height of the vent system. Horizontal runs are measured center pipe to center pipe. • Horizontal runs must have a minimum 1/4” rise per foot and may not run level or down hill. Attaching 4” Flue to BBV: • The first section of B-vent flue should overlap the appliance collar. The appliance collar may be crimped to ease the installation of the first section of flue. • Do not penetrate the pipe inner liner with sheet metal screws. Attach the initial flue section to the top of the firebox chassis with 1/4” self-tapping screws and plumbers strap. Attach the strap toward the bottom of the flue section and pull taut for proper tension to the firebox. Attaching 6” Flue to SBV: • The 6” appliance collar is slightly larger that the inner wall of most B-vent 6” pipe sections. Install the first section of B-vent by slipping the flue’s inner wall tot he inside of the appliance collar. The B-vent outer wall will slip to the outside of the appliance collar. • Do not penetrate the pipe inner line with sheet metal screws. Attach the initial flue section tot he top of the firebox chassis with 1/4” self-tapping screws and plumber’s strap. Attach the strap toward the bottom of the flue section and pull taut for proper tension to the firebox. Support the Pipe • Support horizontal runs a minimum of every five (5) feet. Refer to vent manufacturer’s instructions for proper support on vertical runs (45° or less). • Support offsets so the weight of the pipe is not bearing down on the elbows. B-Vent Pipe Sizing BBV400 SBV400 SBV500 4” 6” 6” FIRESTOPS • Locate chimney centerline dimension from a combustible back wall. Figures 2 & 3. Minimum firestop dimensions are found in the vent manufacturer’s instructions. Clearances to combustibles may also be found on the sides of the flue sections. • Avoid cutting any load-bearing framing members. Figures 6 & 7 To position firestop refer to Figures 6 & 7. Only one firestop is required per frame. NOTICE: When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material. Maintain proper clearances to all combustible materials. NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for the requirements of local building codes. You must follow all local building codes. TERMINATE THE PIPE • Maintain proper clearance t...

Эта инструкция также подходит к моделям:
Камины - B-VENT SBV400 (2.22 mb)
Камины - B-VENT SBV500 (2.22 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории