Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Ativa, модель PET1030

Производитель: Ativa
Размер: 319.81 kb
Название файла: 575-090_manual.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


(upper display) 14 [=] (The final result is automatically rounded to the specified three decimal places.) 400.000 Cancel specification by specifying "Norm" again. [MODE][MODE][MODE][3][1] 400. Before Starting Calculations If after making corrections, input of the formula is To clear memory contents, press [0] [STO] [M]. Addition/subtraction to or from sum in memory cannot be carried out with [M+], [SHIFT] [M–] keys in "SD" mode and "REG" mode. Difference between [STO][M] and [M+], [SHIFT][M–] : Both [STO] [M] and [M+], [SHIFT] [M–] can be used to input results into memory, however when the [STO] [M] operation is used, previous memory contents are cleared. When either [M+] or [SHIFT] [M–] is used, value is added or subtracted to or from present sum in memory. Example: Input 456 into memory "M" using [STO] [M] procedure. Memory already contains value of 123. Operation Modes complete, the answer can be obtained by pressing [ = ]. If, however, more is to be added to the formula, advance the When using this calculator, it is necessary to select the cursor using the [4] key to the end of the formula for proper mode to meet your requirements. This can be done input. by pressing [MODE] to scroll through sub-menus. Then select the appropriate mode by keying in the number. If an unnecessary character has been included in a formula, use the [3] and [4] keys to move to the position of the error and press the "DEL" key. Each press Press [MODE] once to read the first page of the main of "DEL" will delete one command ( one step ). menu. COMP SD REG 1 2 3 AT-30i Example: To correct an input of 369 . . 2 to 369 . 2 : 369xx2_ D 0. 369x2 D 0. 369[.][.]2 Press [MODE] again. [3][3][DEL] Deg Rad Gra1 2 3 M= M M M M 123. D M= 456. D _ 0. D M= 456. D [ON/AC] [1] [2] [3] [STO] [M] Rounding the Intermediate Result Press [MODE] further. Fix Sci Norm 1 2 3 As the number of decimal places is specified, the If a character has been omitted from a formula, use the [ON/AC] [4] [5] [6] [STO] [M] intermediate result will be automatically rounded to the [3] and [4] key to move to the position where the character should have been input, and press [SHIFT] 2-lines display specified decimal places. However, the stored Scientific Calculator intermediate result is not rounded. In order to match the Press "MODE" once more to leave the menu. followed by [INS] key. Each press of [SHIFT] [INS] will [ON/AC] _ 0. displayed value and the stored value, [SHIFT] [Rnd] can be input. Example: To correct an input of 2.362 to sin 2.362 : create a space for input of one command. [RCL] [M] 2[•]36[x2] You can compare the final result obtained in the previous Calculation Modes example with the final result of the following example. with advance "COMP" mode : - general calculations, including function calculations can be executed. statistical functions "SD" mode:- standard deviation calculation can be [3][3][3][3][3] executed. "SD" symbol appears in display. "REG" mode:- regression calculations can be performed. "REG" symbol appears in display. [SHIFT][INS] Example: Input 456 into memory "M" using M+. Memory already contains value of 123. Angular Measurement Modes "DEG" mode:- specify measurement in "degrees". "D" [sin] symbol appears in display window. "RAD" mode:- specify measurement in "radians". "R" 2.362 _ D 0. 2.362 D 0. .362 D 0. sin .362 D 0. symbol appears in display window. When [SHIFT] [INS] are pressed, the space that is opened Example Operation Display (Lower) 200.7.14 = 400 200[.]7 [.] 14[=] 400. rounded to 3 decimal places [MODE][MODE][MODE][1][3] 400.000 200[.]7 [=] The intermediate result is automatically rounded to the specified three decimal places. 28.571 round the stored intermediate result to the specified three decimal places [SHIFT] [Rnd] 28.571 [.] Ans . (upper display) 14 [=] 399.994 Cancel specification by specifying "Norm" again. [MODE][MODE][MODE][3][1] 399.994 [ON/AC] [1] [2] [3] [STO] [M] [ON/AC] [4] [5] [6] [M+] [ON/AC] [RCL] [M] M M M M M= 123. D 456 456. D _ 0. D M= 579. D Owner's Manual Safety Precautions is displayed as " ". The function or value assigned to the "GRA" mode:- specify measurement in "grads". "G" symbol appears in display window. Display Modes "FIX" mode:- specify number of decimal places. "Fix" symbol appears in display window. "SCI" mode:- specify number of significant digits. "Sci" symbol appears in display window. next key you press will be inserted in the . To exit from the insertion mode, move the cursors, or press [SHIFT] [INS] , or press [=]. Even after the [=] key has been pressed to calculate a result, it is possible to use this procedure for correction. Press the [3] key to move the cursor to the place where the correction is to be made. Please read before using. – 4 – – 8 – – 12 – – 16 – Arithmetic Operations & Parenthesis Calculations "NORM" mode:- cancels "Fix" and "Sci" specifications. Special Functions Specifying the Number of Significant Digits Be sure to read the following safety precautions before u...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории