Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Humminbird, модель 300 SERIES 345C DI

Производитель: Humminbird
Размер: 4.13 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


you don’t have to exit the menu to apply the change to the screen). Main Menu 39 Quick Tips for the Main Menu • From any menu option on a menu tab, press the EXIT key to jump directly to the top of the tab. • From the bottom of a menu tab, press the DOWN Cursor key to jump directly to the top of the tab. • From the top of a menu tab, press the LEFT or RIGHT Cursor keys to scroll to the next tab. You can also jump to the beginning or end of the tab rotation by repeatedly pressing the RIGHT or LEFT Cursor keys. • If there is a down arrow at the bottom of a menu tab, press the DOWN Cursor key to scroll to additional menu options. • If there is a right or left arrow on a menu option, press the RIGHT or LEFT Cursor keys to make setting changes or see more information. • If you press MENU or EXIT to leave the Main Menu and then return to the Main Menu at a later time, the menu will open to the same tab as the last time the Main Menu was displayed. Note for all Menu Settings The settings in all menus are adjusted in the same way. Simply use the 4-WAY Cursor Control key to highlight a menu option, and then change the settings or activate the option (see Main Menu or X-Press™ Menu). Below is an example of how the menu options are described in this manual. Each description shows the menu option appearance, the available settings, and the specific control head settings required (i.e. advanced user mode, international only, view, navigation, or accessory). Menu Option Name Setup User Mode and other control head requirements Available Menu Settings and Default Setting Description MenuOptionasitappearsonthescreen 40 Main Menu User Mode (Normal or Advanced) Menu options can be simplified or expanded by setting your Fishfinder User Mode to Normal or Advanced. Normal Mode is the default setting when you first power on your 300 Series™ Fishfinder. Normal mode is provided for users who want greater simplicity and fewer menu choices. Advanced Mode is provided for users who want the highest level of control over the Fishfinder. Several menu settings are added to the Main Menu when the User Mode is changed to Advanced. To change the User Mode setting: 1. Press the MENU key twice to access the Main Menu. 2. Press the RIGHT Cursor key until the Setup tab is selected. 3. Press the DOWN Cursor key to highlight User Mode on the Setup main menu. 4. Press the LEFT or RIGHT Cursor keys to change the User Mode setting. (Normal, Advanced, Default = Normal) NOTE: Any changes made while in Advanced Mode will remain in effect after you switch back to Normal Mode. For example, the Select Readouts menu option is available when the User Mode is set to Advanced. If you change the Select Readouts settings while operating in Advanced User mode, the Select Readouts you choose will continue to display on the screen even if you switch back to Normal User Mode. Main Menu 41 SonarMenuTab,NormalModeSonarMenuTab,NormalMode Sonar Menu Tab, Advanced Mode 42 Main Menu Sonar X-Press™ Menu (Sonar Views only) The Sonar X-Press™ Menu provides a shortcut to your most frequently-used settings. Press the MENU key once while in any of the Sonar Views to access the Sonar X-Press™ Menu. NOTE: Menu options can be expanded or simplified by setting the Fishfinder User Mode to Advanced or Normal. See Main Menu: User Mode for details. NOTE: Menu options are determined by your Humminbird® model. See the following pages for full menu descriptions. Sonar X-Press™ Menu Sonar X-Press™ Menu 43 SensitivitySettings:Low=1,High=20;Default=10SensitivitySettings:Low=1,High=20;Default=10 Sensitivity controls how much detail is shown on the display and will adjust the sensitivity of all sonar frequencies. When operating in very clear water or greater depths, increase the sensitivity to see weaker returns that may be of interest. If the sensitivity is adjusted too high, the display may become too cluttered. Decrease the sensitivity to eliminate the clutter from the display that is sometimes present in murky or muddy water. If Sensitivity is adjusted too low, the display may not show many sonar returns that could be fish. NOTE: The Sensitivity setting is a global setting and will adjust the sensitivity of all sonar frequencies. Sensitivity at Low Sensitivity at Medium Sensitivity at High 44 Sonar X-Press™ Menu Upper Range (Advanced: Sonar, Split Sonar, Circular Flasher, and Big Digits Views only) Settings: 0 to 990 feet or 0 to 327 meters [International Models only]; Default = 0 feet Upper Range sets the shallowest depth range that will be displayed on the Sonar, Split Sonar, Circular Flasher, and Big Digits Views. Upper Range is often used with Lower Range. For example, if you are only interested in the area between 20 and 50 feet deep, you should set the Upper Depth Range to 20 and the Lower Depth Range to 50. The Sonar View will then show the 30 foot area between 20 and 50 and will not show the surface or the bottom (assuming the bottom is deeper than 50 feet). Greater detail will be ...

Эта инструкция также подходит к моделям:
Эхолоты - 300 SERIES 345C (4.13 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории