Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Chromalox, модель ADH-005

Производитель: Chromalox
Размер: 644.87 kb
Название файла: IM-PF438.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Net. Wt. (Lbs.) Model Approx. Net. Wt. (Lbs.) Volts Phase kW No. Elements No. Mtg. Holes 9/32” Dia. No. Circuits Dimensions (In.) A B C D E H K L M ADH-005 ADH-010 ADH-015 8 15 25 ADHT-005 ADHT-010 ADHT-015 10 20 30 480 480 480 3 3 3 5 10 15 3 6 9 10 10 12 1 1 1 5-5/8 7-5/8 9-5/8 20-3/8 20-3/8 20-3/8 28-1/8 28-1/8 28-1/8 4 6 8 1/4 1/4 1/4 2-1/2 3-1/2 3 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-020 ADH-025 ADH-030 35 40 55 ADHT-020 ADHT-025 ADHT-030 40 50 65 480 480 480 3 3 3 20 25 30 12 15 18 14 14 14 1 1 1 11-5/8 13-5/8 15-5/8 20-3/8 20-3/8 20-3/8 28-1/8 28-1/8 28-1/4 10 12 14 1/4 1/4 3/8 2-3/4 3-1/4 3-3/4 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-035 ADH-040 ADH-045 65 70 80 ADHT-035 ADHT-040 ADHT-045 80 90 100 480 480 480 3 3 3 35 40 45 21 24 27 14 14 14 1 2 2 17-5/8 19-5/8 21-5/8 20-3/8 20-3/8 20-3/8 28-1/4 28-1/4 28-1/4 16 18 20 3/8 3/8 3/8 4-1/4 4-3/4 5-1/4 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-050 ADH-060 ADH-080 90 105 140 ADHT-050 ADHT-060 ADHT-080 110 130 175 480 480 480 3 3 3 50 60 80 30 36 48 14 18 22 2 2 4 23-5/8 27-5/8 35-5/8 20-3/8 20-3/8 20-3/8 28-1/4 28-1/4 28-1/4 22 26 34 3/8 3/8 3/8 5-3/4 4-1/2 4-3/8 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-090 ADH-100 — 160 175 — ADHT-090 ADHT-100 ADHT-120 200 220 205 480 480 480 3 3 3 90 100 120 54 60 36 22 22 18 5 5 4 39-5/8 43-5/8 27-5/8 20-3/8 20-3/8 35 28-1/4 28-1/4 42-7/8 38 42 26 3/8 3/8 3/8 4-7/8 5-3/8 4-1/2 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 ADH-144 — ADH-162 165 — 185 — ADHT-160 — — 270 — 480 480 480 3 3 3 144 160 162 48 48 54 22 22 22 4 8 6 35-5/8 35-5/8 39-5/8 35 35 35 42-7/8 42-7/8 42-7/8 34 34 38 3/8 3/8 3/8 4-3/8 4-3/8 4-7/8 3-1/2 3-1/2 3-1/2 11-1/8 11-1/8 11-1/8 9-1/2 9-1/2 9-1/2 — ADH-216F — — 240 — ADHT-180 — ADHT-240F 305 — 400 480 480 480 3 3 3 180 216 240 54 72 72 22 22 22 6 6 8 39-5/8 27-5/8 27-5/8 35 35 35 42-7/8 42-7/8 42-7/8 38 26 26 3/8 3/8 3/8 4-7/8 4-1/2 4-1/2 3-1/2 3-7/8 3-7/8 11-1/8 20 20 9-1/2 18-3/8 18-3/8 ADH-270F — 300 — — ADHT-300F — 500 480 480 3 3 270 300 90 90 22 22 8 10 33-5/8 33-5/8 35 35 42-7/8 42-7/8 32 32 3/8 3/8 5-1/2 5-1/2 3-7/8 3-7/8 20 20 18-3/8 18-3/8 Type ADH Type ADHT Airflow Direction Airflow Direction Figure 1 — Dimensions Figure 2 — Dimensions © 2004 Chromalox, Inc. GENERAL FIRE/EXPLOSION HAZARD. This heater is not intended for use in hazardous atmospheres where flammable vapors, gases, liquids or other combustible atmospheres are present as defined in the National Electrical Code. Failure to comply can result in personal injury or property damage. 1. Heater construction characteristics — A. Alloy sheathed tubular elements, .475” diameter B. Steel flange C. Stainless steel support construction D. High temperature alloy terminals and connections E. Replaceable individual heating elements F. Wiring terminals located outside the heated zone 2. Maximum Temperatures — Types ADH and ADHT process air heaters can generally be used at the following maximum temperatures shown, provided the minimum air velocity is maintained uniformly through the heater. Air Velocity (Ft./Sec.) Max. Outlet Air Temp. (°F) ADH ADHT 4 800 1050 9 800 1100 16 800 1150 25 800 1200 36 800 1200 CAUTION: Do not energize heater in air with a velocity less than 1 Ft. Per Second. 3. The heater may be bolted to the duct with the terminal housing and flange at the top, at either side or at the bottom. 4. Several heaters may be mounted in tandem so long as proper controls are used to limit the maximum temperature attained. 5. Installation with duct transitions in some air distribution systems, the duct heater may be considerably larger than the duct- work and the duct area must be increased by a sheet metal tran45° 45° Max 30" Max 30° Duct HeaterAir Flow 4 Ft. Min. 4 Ft. Min.Figure 3 sition. The slope of the transformation piece on the upstream side of the equipment is limited to 30° as indicated in Figure 3. On the leaving side, the slope should not be more than 45°. 6. Use moisture proof terminal cover in atmospheres bearing corrosive fumes or excessive moisture. 7. Use explosion resistant heaters in explosive atmospheres and reduce current rating to elements. 8. Gas tight design — Achieved by the use of threaded fittings with fiber washers to attach heating elements to flange — pre vents leakage of ducted air into terminal housing. 9. Overtemperature protection — Thermocouple fastened to the element sheath surface and wired to a terminal block can be provided for accurate overheat protection (standard on ADHT models). 10. Flange mounting gasket — Packed separately with each duct heater to minimize air leakage between the flange and air duct. Refer to Table B and Figure 4. Specifications — Table B Flange Gasket Part No. Flange Size Used On ADH and ADHT 168-055429-001 11-1/8 x 5-5/8 5 kW 168-055429-002 11-1/8 x 7-5/8 10 kW 168-055429-003 11-1/8 x 9-5/8 15 kW 168-055429-004 11-1/8 x 11-5/8 20 kW 168-055429-005 11-1/8 x 13-5/8 25 kW 168-055429-...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории